List-mode image reconstruction for the high resolution ClearPET/spl trade/ Neuro system

Conventionally, positron emission tomography data are sorted into sinograms prior to image reconstruction. This leads to a loss of spatial and temporal resolution due to histogramming of events. An alternative data representation is the so-called list-mode format which allows to store more attributes of each individual event, like involved detectors, energy, time, gantry state or even the depth of interaction. The format has the advantage, that it keeps the data in their highest possible temporal and spatial resolution. The additional number of attributes, if considered in the system model, can lead to a significant improvement in image quality. We develop a subsetized list-mode expectation-maximization image reconstruction with a ray-tracing technique to compute an enhanced system model. The algorithm approximates the three-dimensional coincidence response function for two arbitrarily oriented cubic detector elements, incorporated into crystal matrices. The geometry of the involved detector modules is evaluated at event time, tracing the ray paths of gamma quanta from one detector to the other through the field of view. The algorithm has been assessed using list-mode data for the ClearPET/spl trade/ Neuro, and is compared to a standard ordered-subset expectation-maximization reconstruction method for projections.

[1]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[2]  S R Cherry,et al.  An improved analytical detector response function model for multilayer small-diameter PET scanners. , 2003, Physics in medicine and biology.

[3]  Habib Zaidi,et al.  An Object-Oriented Library for 3D PET Reconstruction Using Parallel Computing , 1999, Bildverarbeitung für die Medizin.

[4]  P. Lecoq,et al.  Advances in the scintillation performance of LuYAP:Ce single crystals , 2005 .

[5]  K. Erlandsson,et al.  Fast accurate iterative reconstruction for low-statistics positron volume imaging. , 1998, Physics in medicine and biology.

[6]  Carole Lartizien,et al.  The ClearPET™ project: development of a 2nd generation high-performance small animal PET scanner , 2005 .

[7]  G. Kemmerling,et al.  Comparison of LuYAP, LSO and BGO as scintillators for high resolution PET detectors , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[8]  Andrew J. Reader,et al.  Regularized one-pass list-mode EM algorithm for high resolution 3D PET image reconstruction into large arrays , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[9]  A J Reader,et al.  Statistical list-mode image reconstruction for the high resolution research tomograph. , 2004, Physics in medicine and biology.

[10]  Greg Burns,et al.  LAM: An Open Cluster Environment for MPI , 2002 .

[11]  Andrew J. Reader,et al.  One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays , 2002 .

[12]  A. Rahmim,et al.  Study of a convergent subsetized list-mode EM reconstruction algorithm , 2004, IEEE Symposium Conference Record Nuclear Science 2004..