Identification of the Critical Characteristics of Different Types of Voltage Sags for Synchronous Machine Torque Oscillations

Abstract—This article investigates the effects of symmetrical and unsymmetrical voltage sags on an important characteristic of torque pulsation of synchronous machines. Voltage sags may cause high torque pulsations, which can damage the shaft or equipment connected to it. Duration, magnitude,and initial point-on-wave of the voltage sag are the major characteristics that can influence the synchronous motors torque transients. The effect of the characteristics on the severity of the transient torque is clarified parametrically, and the critical characteristics of each type of voltage sag are extracted. A theoretical analysis is first presented to determine the severest conditions. In this analysis, for each type of voltage sag, the stator flux trajectory in complex coordination is traced to monitor its variation during and after sag. By this method, the effects of different sag types can easily be compared during the sag and at the sag ending instant. To justify the theoretical analysis, simulations of a typical synchronous motor are carried out that confirm the theoretical analysis.

[1]  H. Wayne Beaty,et al.  Electrical Power Systems Quality , 1995 .

[2]  F. Carlsson Explanation to irregularities in the dependence between voltage sag magnitude and the tripping level for line operated synchronous machines , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[3]  Math Bollen,et al.  Tutorial on voltage sag analysis , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[4]  Tze-Fun Chan,et al.  Synchronous Machines , 2011, Electrical Machine Fundamentals with Numerical Simulation using MATLAB/SIMULINK.

[5]  Narayan C. Kar,et al.  Effect of Voltage Sag on the Transient Performance of Saturated Synchronous Motors , 2006, 2006 Canadian Conference on Electrical and Computer Engineering.

[6]  H.-P. Nee,et al.  Analysis of peak torque of line-operated synchronous machines subjected to symmetrical voltage sags , 2002 .

[7]  J. Pedra,et al.  Effects of symmetrical and unsymmetrical voltage sags on induction machines , 2004, IEEE Transactions on Power Delivery.

[8]  J. C. Das Effects of momentary voltage dips on the operation of induction and synchronous motors , 1989, Conference Record. Industrial and Commercial Power Systems Technical Conference.

[9]  Thomas A. Lipo Reference Frame Theory , 2012 .

[10]  M. H. J. Bollen Voltage Recovery after Unbalanced and Balanced Voltage Dip in Three-Phase Systems , 2002, IEEE Power Engineering Review.

[11]  Pedro Rodriguez,et al.  Symmetrical and unsymmetrical voltage sag effects on the three-phase synchronous machine stability , 2009, 2009 13th European Conference on Power Electronics and Applications.

[12]  J. Arrillaga,et al.  Power quality following deregulation , 2000, Proceedings of the IEEE.

[13]  M.H.J. Bollen,et al.  Voltage sag coordination for reliable plant operation , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[14]  D. Söffker Terms and definitions , 2021, What is Space-Time Made of ?.