Coupling ATMD System for Seismic Response Control of Two Adjacent Buildings

This study deals with optimal control of the coupling active tuned mass damper (ATMD) system for two neighboring structures under earthquake excitations. It also investigates the seismic performances of the proposed system including the issues on actuator failure problems. The conventional control approach is to use two ATMDs independently where each ATMD is individually installed at each structure without any connection between two structures. Since this uncoupling configuration does not allow transferring its control force to the other structure, it cannot adapt to emergency situation in which one of the two actuators becomes inoperable due to the power cuts or outages. On the other hand, the proposed control approach is to use a coupling ATMD system where two ATMDs with one mass being shared are installed to interconnect two structures. Hence, the proposed coupling ATMD system can transmit the control force of the remaining actuator to another structure through the interconnection configuration so that it can adapt to the one-side actuator failure. In a numerical example, the conventional independent and newly proposed coupling systems have been optimally designed to have similar control performance in normal operational conditions, and their performances have been compared to each other under the malfunction conditions of one-side actuator. Their comparative results verified the outstanding adaptive performance of the proposed coupling ATMD system over the independent ATMD system. The independent ATMD system showed considerably degraded control performance compared to its own normal control performance, whereas the proposed system exhibits much improved control performance over the independent ATMD system by fully utilizing the other normally operating actuators through the coupling configuration.

[1]  Erik A. Johnson,et al.  Coupled Building Control Considering the Effects of Building/Connector Configuration , 2006 .

[2]  D. E. Goldberg,et al.  Genetic Algorithms in Search , 1989 .

[3]  W. Marsden I and J , 2012 .

[4]  S. M. Dumne,et al.  Seismic response analysis of adjacent buildings connected with MR dampers , 2010 .

[5]  Hamid Reza Karimi,et al.  Allocation of Actuators and Sensors for Coupled-Adjacent-Building Vibration Attenuation , 2013, IEEE Transactions on Industrial Electronics.

[6]  Frank L. Lewis,et al.  Applied Optimal Control and Estimation , 1992 .

[7]  Seung-Yong Ok,et al.  Optimal design of actively controlled adjacent structures for balancing the mutually conflicting objectives in design preference aspects , 2012 .

[8]  T. T. Soong,et al.  STRUCTURAL CONTROL USING ACTIVE TUNED MASS DAMPERS , 1980 .

[9]  John O Sobanjo,et al.  Use of a shared tuned mass damper (STMD) to reduce vibration and pounding in adjacent structures , 2001 .

[10]  M. Rabins,et al.  Semi‐Active versus Passive or Active Tuned Mass Dampers for Structural Control , 1983 .

[11]  Seung-Yong Ok,et al.  Modal-space reference-model-tracking fuzzy control of earthquake excited structures , 2015 .

[12]  J. Enrique Luco,et al.  Optimal damping between two adjacent elastic structures , 1998 .

[13]  Seung-Yong Ok,et al.  Optimal design of hybrid control system for new and old neighboring buildings , 2015 .

[14]  Fahim Sadek,et al.  A METHOD OF ESTIMATING THE PARAMETERS OF TUNED MASS DAMPERS FOR SEISMIC APPLICATIONS , 1997 .

[15]  Gebrail Bekdaş,et al.  Mass ratio factor for optimum tuned mass damper strategies , 2013 .

[16]  Yozo Fujino,et al.  Design formulas for tuned mass dampers based on a perturbation technique , 1993 .

[17]  Isao Nishimura,et al.  Active tuned mass damper , 1992 .

[18]  J. P. Hartog Mechanical vibration / J.P. Den Hartog , 1956 .

[19]  Yi-Qing Ni,et al.  RANDOM SEISMIC RESPONSE ANALYSIS OF ADJACENT BUILDINGS COUPLED WITH NON-LINEAR HYSTERETIC DAMPERS , 2001 .

[20]  S. M. Dumne,et al.  Seismic response analysis of coupled building involving MR damper and elastomeric base isolation , 2015 .

[21]  Abdelhafid Ounis,et al.  Pounding hazard mitigation between adjacent planar buildings using coupling strategy , 2016 .

[22]  Henry T. Y. Yang,et al.  Simple ATMD Control Methodology for Tall Buildings Subject to Wind Loads , 1996 .

[23]  R. S. Jangid,et al.  Harmonic response of adjacent structures connected with a friction damper , 2006 .

[24]  Mehmet E. Uz,et al.  Optimal design of semi active control for adjacent buildings connected by mr damper based on integrated fuzzy logic and multi-objective genetic algorithm , 2014 .

[25]  Seung-Yong Ok,et al.  Hybrid control approach for seismic coupling of two similar adjacent structures , 2015 .

[26]  Hengjia Zhu,et al.  Optimum parameters of Maxwell model-defined dampers used to link adjacent structures , 2005 .