Laser-induced breakdown spectroscopy for detection of heavy metals in environmental samples

The application of LIBS technology as a sensor for heavy metals in solid environmental samples has been studied. This specific application introduces some new problems in the LIBS analysis. Some of them are related to the particular distribution of contaminants in the grained samples. Other problems are related to mechanical properties of the samples and to general matrix effects, like the water and organic fibers content of the sample. An attempt has been made to optimize the experimental set-up for the various involved parameters. The understanding of these factors has enabled the adjustment of the technique to the substrates of interest. The special importance of the grain size and of the laser-induced aerosol production is pointed out. Calibration plots for the analysis of heavy metals in diverse sand and soil samples have been carried out. The detection limits are shown to be usually below the recent regulation restricted concentrations.

[1]  David C. Smith,et al.  Gas breakdown initiated by laser radiation interaction with aerosols and solid surfaces , 1977 .

[2]  D. K. Ottesen,et al.  Real-Time Laser Spark Spectroscopy of Particulates in Combustion Environments , 1989 .

[3]  E. Piepmeier,et al.  Chemical Dynamics of a Laser Microprobe Vapor Plume in a Controlled Atmosphere , 1984 .

[4]  David A. Cremers,et al.  The Analysis of Metals at a Distance Using Laser-Induced Breakdown Spectroscopy , 1987 .

[5]  A. S. Silenok,et al.  Fire ball formation and evolution in the case of low‐threshold optical breakdown plasma generation in ambient gases in front of various solid samples , 1989 .

[6]  S. Chenery,et al.  Nature of particulate matter produced by laser ablation—implications for tandem analytical systems , 1990 .

[7]  E. Piepmeier,et al.  Laser ablation and the laser microprobe , 1988 .

[8]  K. Niemax,et al.  Internal standardization in laser induced fluorescence spectrometry of microplasmas produced by laser ablation of solid samples , 1990 .

[9]  E. Yeung,et al.  Acoustic signal as an internal standard for quantitation in laser-generated plumes , 1988 .

[10]  K. Niemax,et al.  Optical emission spectrometry and laser-induced fluorescence of laser produced sample plumes. , 1990, Applied optics.

[11]  A. Zardecki,et al.  Diffusive and convective vaporization of irradiated droplets , 1987 .

[12]  T. Loree The detection of elements in biomedical fluids by laser-induced breakdown spectroscopy , 1983 .

[13]  Michael C. Cates Excimer-laser-produced plasma studies , 1990, Other Conferences.

[14]  G. L. Paul,et al.  Time-Resolved Laser-Induced Breakdown Spectroscopy of Iron Ore , 1990 .

[15]  T. Hall,et al.  Enhanced line emission from laser‐produced plasmas , 1991 .