Investigation of mode identifiability of a cable-stayed bridge : comparison from ambient vibration responses and from typhoon-induced dynamic responses

Modal identification of civil engineering structures based on ambient vibration measurement has been widely investigated in the past decades, and a variety of output-only operational modal identification methods have been proposed. However, vibration modes, even fundamental low-order modes, are not always identifiable for large-scale structures under ambient vibration excitation. The identifiability of vibration modes, deficiency in modal identification, and criteria to evaluate robustness of the identified modes when applying output-only modal identification techniques to ambient vibration responses were scarcely studied. In this study, the mode identifiability of the cable-stayed Ting Kau Bridge using ambient vibration measurements and the influence of the excitation intensity on the deficiency and robustness in modal identification are investigated with long-term monitoring data of acceleration responses acquired from the bridge under different excitation conditions. It is observed that a few low-order modes, including the second global mode, are not identifiable by common output-only modal identification algorithms under normal ambient excitations due to traffic and monsoon. The deficient modes can be activated and identified only when the excitation intensity attains a certain level (e.g., during strong typhoons). The reason why a few low-order modes fail to be reliably identified under weak ambient vibration excitations and the relation between the mode identifiability and the excitation intensity are addressed through comparing the frequency-domain responses under normal ambient vibration excitations and under typhoon excitations and analyzing the wind speeds corresponding to different response data samples used in modal identification. The threshold value of wind speed (generalized excitation intensity) that makes the deficient modes identifiable is determined.

[1]  A. B. Dunwoody,et al.  A Mathematical Basis for the Random Decrement Vibration Signature Analysis Technique , 1982 .

[2]  Chin-Hsiung Loh,et al.  Stochastic subspace identification for output‐only modal analysis: application to super high‐rise tower under abnormal loading condition , 2013 .

[3]  A. M. Abdel-Ghaffar,et al.  Ambient Vibration Studies of Golden Gate Bridge: I. Suspended Structure , 1985 .

[4]  B. Peeters,et al.  Stochastic System Identification for Operational Modal Analysis: A Review , 2001 .

[5]  J. C. Asmussen,et al.  Modal Analysis Based on the Random Decrement Technique: application to civil engineering structures , 1997 .

[6]  Chin-Hsiung Loh,et al.  SSA-based stochastic subspace identification of structures from output-only vibration measurements , 2012 .

[7]  Filipe Magalhães,et al.  Challenges in the Application of Stochastic Modal Identification Methods to a Cable-Stayed Bridge , 2007 .

[8]  Tian-Li Huang,et al.  Updating finite element model using dynamic perturbation method and regularization algorithm , 2012 .

[9]  George W. Housner,et al.  Ambient Vibration Tests of a Suspension Bridge , 1978 .

[10]  Yang Wang,et al.  Output-only modal identification of a cable-stayed bridge using wireless monitoring systems , 2008 .

[11]  Rune Brincker,et al.  Modal identification of output-only systems using frequency domain decomposition , 2001 .

[12]  Kai-Yuen Wong,et al.  Design of a structural health monitoring system for long-span bridges , 2007 .

[13]  Yong-Lin Pi,et al.  Modal Identification of Vibrating Structures Using ARMA Model , 1989 .

[14]  Svend Gade,et al.  Frequency Domain Techniques for Operational Modal Analysis , 2005 .

[15]  Rune Brincker,et al.  Using Enhanced Frequency Domain Decomposition as a Robust Technique to Harmonic Excitation in Operational Modal Analysis , 2006 .

[16]  Bart De Moor,et al.  Subspace algorithms for the stochastic identification problem, , 1993, Autom..

[17]  Raimundo Delgado,et al.  Dynamic Tests on Large Cable-Stayed Bridge , 2001 .

[18]  S. R. Ibrahim Random Decrement Technique for Modal Identification of Structures , 1977 .

[19]  A. M. Abdel-Ghaffar,et al.  Ambient Vibration Studies of Golden Gate Bridge , 1985 .

[20]  Yi-Qing Ni,et al.  Technology developments in structural health monitoring of large-scale bridges , 2005 .

[21]  Yi-Qing Ni,et al.  Health Checks through Landmark Bridges to Sky-High Structures , 2011 .

[22]  Joel P. Conte,et al.  Study of Time-Domain Techniques for Modal Parameter Identification of a Long Suspension Bridge with Dense Sensor Arrays , 2009 .

[23]  Kai-Yuen Wong,et al.  Instrumentation and health monitoring of cable‐supported bridges , 2004 .

[24]  Yi-Qing Ni,et al.  Multi-stage identification scheme for detecting damage in cable-stayed Kap Shui Mun Bridge , 2002 .

[25]  Filipe Magalhães,et al.  Dynamic monitoring of a long span arch bridge , 2008 .

[26]  Filipe Magalhães,et al.  Ambient vibration re-testing and operational modal analysis of the Humber Bridge , 2010 .

[27]  Lee D. Peterson Efficient computation of the eigensystem realization algorithm , 1995 .

[28]  Michael Schlaich,et al.  Ting Kau Bridge, Hong Kong , 1996 .

[29]  Thomas G. Carne,et al.  The Natural Excitation Technique (NExT) for modal parameter extraction from operating wind turbines , 1993 .

[30]  Yozo Fujino,et al.  System identification of suspension bridge from ambient vibration response , 2008 .

[31]  Alberto Zasso,et al.  Humber bridge full scale measure campaigns 1990-1991 , 1994 .

[32]  Guido De Roeck,et al.  REFERENCE-BASED STOCHASTIC SUBSPACE IDENTIFICATION FOR OUTPUT-ONLY MODAL ANALYSIS , 1999 .

[33]  Jer-Nan Juang,et al.  An eigensystem realization algorithm for modal parameter identification and model reduction. [control systems design for large space structures] , 1985 .

[34]  John R. Mather,et al.  Beaufort wind scale , 1987 .

[35]  Jan Ming Ko,et al.  Evaluation of typhoon induced fatigue damage using health monitoring data for the Tsing Ma Bridge , 2004 .

[36]  Poul Henning Kirkegaard,et al.  Identification of Civil Engineering Structures using Vector ARMA Models , 1998 .

[37]  P. Barney,et al.  Modal parameter extraction using natural excitation response data , 1998 .

[38]  P. Andersen,et al.  Understanding Stochastic Subspace Identification , 2006 .