Early In Vivo Experience With the Pediatric Jarvik 2000 Heart

The need for smaller, more efficient ventricular assist devices that can be used in a more chronic setting have led to exploration of mechanical circulatory support in the pediatric population. The pediatric Jarvik 2000 heart (child size), under development, was implanted in six juvenile sheep and studied for both acute fit and chronic performance evaluation. Daily hemodynamic measurements of cardiac output and pump output at varying pump speeds were taken. In addition, plasma free hemoglobin, lactic acid dehydrogenase, and platelet activation from blood samples were determined at baseline, after implantation, and twice a week thereafter. The measured flow through the outflow graft at increasing speeds from 10,000 rpm to 14,000 rpm with an increment of 1,000 rpm were 1.47 ± 0.43, 1.89 ± 0.52, 2.36 ± 0.61, 2.80 ± 0.73, and 3.11 ± 0.86 (L/min). The baseline plasma free hemoglobin was 11.95 ± 4.76 (mg/dL), with subsequent mean values being <30 mg/dL at postimplantation and weekly postimplantation measurements. Both lactic acid dehydrogenase and platelet activation showed an acute increase within the first week after implantation with subsequent return to baseline by 2 weeks after surgery. Our initial animal in vivo experience with the pediatric Jarvik 2000 heart shows that a small axial flow pump can provide partial to nearly complete circulatory support with minimal adverse effects on blood components.

[1]  M. Oz,et al.  Indications and patient selection for mechanical ventricular assistance. , 2001, The Annals of thoracic surgery.

[2]  Harvey S Borovetz,et al.  The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program. , 2005, Circulation.

[3]  T. Jikuya,et al.  赤血球機械的脆性における種差 ヒト,ウシ及びヒツジ細胞の比較 , 1998 .

[4]  Y Sankai,et al.  Species differences in erythrocyte mechanical fragility: comparison of human, bovine, and ovine cells. , 1998, ASAIO journal.

[5]  Stephen Westaby,et al.  Initial Clinical Experience With the Jarvik 2000 Implantable Axial-Flow Left Ventricular Assist System , 2002, Circulation.

[6]  P. D. del Nido,et al.  Mechanical circulatory support in children with cardiac disease. , 1999, The Journal of thoracic and cardiovascular surgery.

[7]  N. Smedira,et al.  Mechanical circulatory assistance: state of art. , 2002, Circulation.

[8]  J. Freedman,et al.  Quantification of platelet activation status by analyzing P-selectin expression. , 2000, Biochemical and biophysical research communications.

[9]  J. David Erickson,et al.  Mortality Associated With Congenital Heart Defects in the United States: Trends and Racial Disparities, 1979–1997 , 2001, Circulation.

[10]  B. Duncan Mechanical circulatory support for infants and children with cardiac disease. , 2002, The Annals of thoracic surgery.

[11]  Yoshiyuki Sankai,et al.  Species Differences in Erythrocyte Mechanical Fragility , 1998 .

[12]  R. Malinauskas,et al.  Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices. , 2008, Artificial organs.

[13]  S. Gelsomino,et al.  The CryoLife O'Brien stentless porcine aortic bioprosthesis: 5-year follow-up. , 2001, The Annals of thoracic surgery.