Development and Longer Term In Situ Evaluation of Fiber-Optic Sensors for Monitoring of Structural Concrete

In this paper, new solutions to the problem of making measurements, of carbonation and chloride ingress, in particular, in concrete structures are considered. The approach has focused on the design, development, and use of fiber-optic sensors (FOSs), recognizing the need in that conventional devices are often either inaccurate, expensive, or unsuitable for encapsulation in the material. The sensors have been designed to monitor, in situ and nondestructively, relevant physical, and chemical changes in cementitious materials. Three different types of FOS were constructed, tested, and evaluated specifically for this application, these being a temperature sensor (based on the fluorescence decay) and pH and chloride sensors, based on sol-gel (solidified gel) technology with appropriate impregnated indicators. The sensors were all designed to be inserted into the structures and evaluated under the harshest conditions, i.e., being mounted when the mortar is poured and thus tested in situ, with the temperature and pH sensors successfully embedded in mortar. The outcomes of these tests have shown that both the temperature sensor and the pH sensor were able to function correctly for the duration of the work - for over 18 months after placement. The laboratory tests on the chloride sensor showed it was able to make measurements but was not reversible, limiting its potential utility for in situ environments. Research is ongoing to refine the sensor performance and extend the testing.

[1]  Kenneth T. V. Grattan,et al.  Fibre optic chemical sensor systems for internal concrete condition monitoring , 2004, European Workshop on Optical Fibre Sensors.

[2]  Alan D. Kersey,et al.  Fiber optic sensors in concrete structures: a review , 1996 .

[3]  William John McCarter,et al.  FIELD TRIALS ON COVERCRETE MONITORING SENSORS , 2001 .

[4]  Carmen Andrade,et al.  Evolution of pH during in-situ leaching in small concrete cavities , 1997 .

[5]  Kenneth T. V. Grattan,et al.  Potential for temperature sensor applications of highly neodymium-doped crystals and fiber at up to approximately 1000 °C , 1997 .

[6]  Nick R. Buenfeld,et al.  An investigation of experimental methods used to determine free and total chloride contents , 1996 .

[7]  Kenneth T. V. Grattan,et al.  New Test Method to Obtain pH Profiles due to Carbonation of Concretes Containing Supplementary Cementitious Materials , 2007 .

[8]  Susan E. Taylor,et al.  Corrosion induced strain monitoring through fibre optic sensors , 2007 .

[9]  Kenneth T. V. Grattan,et al.  Fiber Optic Fluorescence Thermometry , 1994 .

[10]  M. Anson,et al.  Early-age strain and temperature measurements in concrete tank walls , 1988 .

[11]  R. Measures,et al.  Fiber-optic Bragg grating sensors for bridge monitoring , 1997 .

[12]  P B Bamforth,et al.  AN INTERNATIONAL REVIEW OF CHLORIDE INGRESS INTO STRUCTURAL CONCRETE , 1997 .

[13]  K. Grattan,et al.  Impregnation of a pH-sensitive dye into sol–gels for fibre optic chemical sensors , 1995 .

[14]  Daniel C. Harris,et al.  Quantitative Chemical Analysis , 1968, Nature.

[15]  C. Andrade,et al.  Chloride threshold values to depassivate reinforcing bars embedded in a standardized OPC mortar , 2000 .

[16]  Kenneth T. V. Grattan,et al.  Fiber optic sensor technology: an overview , 2000 .

[17]  B. T. Meggitt,et al.  Optical Fiber Sensor Technology , 1999 .

[18]  S. Abrate,et al.  Structural Monitoring with Fiber Optic Technology , 2001 .

[19]  C. Brent Bargeron,et al.  Embedded micro-sensor for monitoring pH in concrete structures , 2000, Smart Structures.

[20]  K.T.V. Grattan,et al.  A field deployable, multiplexed Bragg grating sensor system used in an extensive highway bridge monitoring evaluation tests , 2005, IEEE Sensors Journal.

[21]  Kin-tak Lau,et al.  Fibre-optic sensors and smart composites for concrete applications , 2003 .