Detection of norepinephrine in whole blood via fast scan cyclic voltammetry

Bioelectronic Medicines is an emerging field that capitalizes on minimally-invasive technology to stimulate the autonomic nervous system in order to evoke therapeutic biomolecular changes at the end-organ. The goal of Bioelectronic Medicines is to realize both ‘precision and personalized’ medicine. ‘Precise’ stimulation of neural circuitry creates biomolecular changes targeted exactly where needed to maximize therapeutic effects while minimizing off-target changes associated with side-effects. The therapy is then ‘personalized’ by utilizing implanted sensors to measure the biomolecular concentrations at, or near, the end-organ of interest and continually adjusting therapy to account for patient-specific biological changes throughout the day. To realize the promise of Bioelectronic Medicines, there is a need for minimally invasive, real-time measurement of biomarkers associated with the effects of autonomic nerve stimulation to be used for continuous titration of therapy. In this study we examine the feasibility of using fast scan cyclic voltammetry (FSCV) to measure norepinephrine levels, a neurochemical relevant to end-organ function, directly from blood. FSCV is a well-understood method for measuring electroactive neurochemicals in the central nervous system with high temporal and high spatial resolution that has yet to be adapted to the study of the autonomic nervous system. The results demonstrate that while detecting the electroactive neurochemical norepinephrine in blood is more challenging than obtaining the same FSCV measurements in a buffer solution due to biofouling of the electrode, it is feasible to utilize a minimally invasive FSCV electrode to obtain neurochemical measurements in blood.

[1]  Diane R. Eaker,et al.  Development of the Mayo Investigational Neuromodulation Control System: toward a closed-loop electrochemical feedback system for deep brain stimulation. , 2013, Journal of neurosurgery.

[2]  Pavel Takmakov,et al.  Higher sensitivity dopamine measurements with faster-scan cyclic voltammetry. , 2011, Analytical chemistry.

[3]  Nephi Stella,et al.  Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animals , 2009, Nature Methods.

[4]  P. Phillips,et al.  Subsecond dopamine fluctuations in human striatum encode superposed error signals about actual and counterfactual reward , 2015, Proceedings of the National Academy of Sciences.

[5]  Jinwoo Park,et al.  In vivo voltammetric monitoring of norepinephrine release in the rat ventral bed nucleus of the stria terminalis and anteroventral thalamic nucleus , 2009, The European journal of neuroscience.

[6]  Victor Pikov,et al.  Bioelectronic medicines: a research roadmap , 2014, Nature Reviews Drug Discovery.

[7]  R. Wightman,et al.  Resolving neurotransmitters detected by fast-scan cyclic voltammetry. , 2004, Analytical chemistry.

[8]  J. Born,et al.  Plasma epinephrine and norepinephrine concentrations of healthy humans associated with nighttime sleep and morning arousal. , 1997, Hypertension.

[9]  Michael L Heien,et al.  Fast-scan controlled-adsorption voltammetry for the quantification of absolute concentrations and adsorption dynamics. , 2013, Langmuir : the ACS journal of surfaces and colloids.

[10]  Pavel Takmakov,et al.  Carbon microelectrodes with a renewable surface. , 2010, Analytical chemistry.

[11]  Adam Boretsky,et al.  Acute insertion effects of penetrating cortical microelectrodes imaged with quantitative optical coherence angiography , 2016, Neurophotonics.

[12]  W. Abraham,et al.  Elevated plasma noradrenaline concentrations in patients with low-output cardiac failure: dependence on increased noradrenaline secretion rates. , 1990, Clinical science.

[13]  Garret D Stuber,et al.  Overoxidation of carbon-fiber microelectrodes enhances dopamine adsorption and increases sensitivity. , 2003, The Analyst.

[14]  R. Wightman,et al.  Assessing principal component regression prediction of neurochemicals detected with fast-scan cyclic voltammetry. , 2011, ACS chemical neuroscience.

[15]  Tak W. Mak,et al.  Acetylcholine-Synthesizing T Cells Relay Neural Signals in a Vagus Nerve Circuit , 2011, Science.