A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising?

Abstract Most medical examinations include measuring of blood pressure because it is a very good indicator about the status of the cardiovascular system, and it helps medical doctors to adjust the ideal treatment. It would be very useful to know the profile of pressure values during long time period, especially during standard daily activities. It could be used for homecare monitoring and prevention of premature death. Problem is that blood pressure is monitored mainly at discrete time intervals and use an inflatable cuff placed around the arm, which is uncomfortable for the patient. Currently, there are a few technical solutions for continuous non-invasive measurement of blood pressure. This review is focused on the description of methods for continuous blood pressure measurement including their limitations and especially is focused on the description method based on pulse transit time. This method could be the most widely used of methods for non-invasive long time monitoring of blood pressure in the future but now there are still a lot of unsolved problems.

[1]  Olivier Chételat,et al.  Chest Pulse-Wave Velocity: A Novel Approach to Assess Arterial Stiffness , 2011, IEEE Transactions on Biomedical Engineering.

[2]  In Cheol Jeong,et al.  Introducing a practical approach for non-invasive blood pressure monitoring during home-based telerehabilitation exercise program , 2013, 2013 IEEE Point-of-Care Healthcare Technologies (PHT).

[3]  Claudio Sartori,et al.  Noninvasive and Nonocclusive Blood Pressure Estimation Via a Chest Sensor , 2013, IEEE Transactions on Biomedical Engineering.

[4]  Josep Solà,et al.  Ambulatory monitoring of the cardiovascular system: the role of Pulse Wave Velocity , 2010 .

[5]  A. Hofman,et al.  Arterial Stiffness as Underlying Mechanism of Disagreement Between an Oscillometric Blood Pressure Monitor and a Sphygmomanometer , 2000, Hypertension.

[6]  R. Kattai,et al.  Continuous blood pressure monitoring during exercise using pulse wave transit time measurement , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  J. Ruiz-Rodríguez,et al.  Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology , 2013, Intensive Care Medicine.

[8]  H. Y. Xiang,et al.  Calibration of Pulse Wave Transit Time Method in Blood Pressure Measurement Based on the Korotkoff Sound Delay Time , 2013 .

[9]  Nikos Stergiopulos,et al.  Pulse Wave Propagation in the Arterial Tree , 2011 .

[10]  Spencer J. Sherwin,et al.  Arterial pulse wave haemodynamics , 2012 .

[11]  Gordon R. Williams,et al.  Pulse transit time changes observed with different limb positions , 2005, Physiological measurement.

[12]  P. Shaltis,et al.  A hydrostatic pressure approach to cuffless blood pressure monitoring , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  P. Shaltis,et al.  Towards the Development of Wearable Blood Pressure Sensors: A Photo-Plethysmograph Approach Using Conducting Polymer Actuators , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[14]  T. Togawa,et al.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration , 2000, Medical and Biological Engineering and Computing.

[15]  Yuan-Ting Zhang,et al.  The Effect of Local Cold Exposure on Pulse Transit Time , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[16]  J. Moraes,et al.  Development of a new oscillometric blood pressure measurement system , 1999, Computers in Cardiology 1999. Vol.26 (Cat. No.99CH37004).

[17]  James A. McCubbin,et al.  Pulse transit time: Relationship to blood pressure , 1978 .

[18]  Yuan-Ting Zhang,et al.  Theoretical Study on the Effect of Sensor Contact Force on Pulse Transit Time , 2007, IEEE Transactions on Biomedical Engineering.

[19]  Berend E. Westerhof,et al.  Noninvasive continuous hemodynamic monitoring , 2012, Journal of Clinical Monitoring and Computing.

[20]  P. Wach,et al.  Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops , 2006, Comput. Biol. Medicine.

[21]  P M NEWGARD,et al.  A TRANSDUCER FOR THE CONTINUOUS EXTERNAL MEASUREMENT OF ARTERIAL BLOOD PRESSURE. , 1961, IEEE transactions on bio-medical engineering.

[22]  M. Karvonen,et al.  Sphygmomanometer cuff size and the accuracy of indirect measurement of blood pressure , 1964 .

[23]  Kalju Meigas,et al.  Continuous blood pressure monitoring using pulse wave delay , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  L. A. Geddes,et al.  Handbook of Blood Pressure Measurement , 1991 .

[25]  Stefan Hey,et al.  Continuous Noninvasive Pulse Transit Time Measurement for Psycho-physiological Stress Monitoring , 2009, 2009 International Conference on eHealth, Telemedicine, and Social Medicine.

[26]  Yuan-Ting Zhang,et al.  Cuffless and noninvasive estimation of blood pressure based on a wavelet transform approach , 2003, IEEE EMBS Asian-Pacific Conference on Biomedical Engineering, 2003..

[27]  X. Teng,et al.  The effect of contacting force on photoplethysmographic signals , 2004, Physiological measurement.

[28]  B. Pannier,et al.  Assessment of arterial distensibility by automatic pulse wave velocity measurement. Validation and clinical application studies. , 1995, Hypertension.

[29]  X. Aubert,et al.  Cuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[30]  Hao-Min Cheng,et al.  Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: a systematic review and meta-analysis. , 2013, International journal of cardiology.

[31]  D. A. Mcdonald Blood flow in arteries , 1974 .

[32]  G. C. Jernstedt,et al.  Blood pressure and pulse wave velocity measurement for operant conditioning of autonomic responding , 1974 .

[33]  M. Okada,et al.  Possible determinants of pulse-wave velocity in vivo , 1988, IEEE Transactions on Biomedical Engineering.

[34]  J. D. Bourland,et al.  Measurement of pulse-wave velocity using a beat-sampling technique , 2006, Annals of Biomedical Engineering.

[35]  T. Ma,et al.  A Correlation Study on the Variabilities in Pulse Transit Time, Blood Pressure, and Heart Rate Recorded Simultaneously from Healthy Subjects , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[36]  G. Parati,et al.  Comparison of Finger and Intra‐arterial Blood Pressure Monitoring at Rest and During Laboratory Testing , 1989, Hypertension.

[37]  Yutaka Imai,et al.  European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement , 2003, Journal of hypertension.

[38]  X. Aubert,et al.  Is pulse transit time a good indicator of blood pressure changes during short physical exercise in a young population? , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[39]  L. A. Geddes,et al.  Pulse arrival time as a method of obtaining systolic and diastolic blood pressure indirectly , 1981, Medical and Biological Engineering and Computing.

[40]  Charles Sodini,et al.  A continuous, wearable, and wireless heart monitor using head ballistocardiogram (BCG) and head electrocardiogram (ECG) , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[41]  J. Krauss,et al.  Continuous non-occlusive blood pressure monitoring at the sternum , 2012 .

[42]  Wen-Chung Yu,et al.  Measurement accuracy of a stand-alone oscillometric central blood pressure monitor: a validation report for Microlife WatchBP Office Central. , 2013, American journal of hypertension.

[43]  Wouter Wieling,et al.  Nexfin noninvasive continuous blood pressure validated against Riva-Rocci/Korotkoff. , 2009, American journal of hypertension.

[44]  Zang-Hee Cho,et al.  In-vivo Human Molecular Imaging Using PET-MRI Fusion Imaging Technology , 2012 .

[45]  Carmen C. Y. Poon,et al.  An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects , 2009, Cardiovascular engineering.

[46]  Y. T. Zhang,et al.  Noninvasive and cuffless measurements of blood pressure for telemedicine , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.