Towards true unipolar ECG recording without the Wilson central terminal (preliminary results)

We present an innovative bio-potential front-end capable of recording true unipolar ECG leads for the first time without making use of the Wilson central terminal. In addition to the convenience in applications such as continuous monitoring and rapid diagnosis, the information in unipolar recordings may yield unique diagnostic information as it avoids the need to essentially subtract data or make use of the averaging effect imposed from the Wilson central terminal. The system also allows direct, real-time software calculation of signals corresponding to standard ECG leads which achieve correlations in excess of 92% with a gold standard ECG during a parallel in vivo recording. In addition, the implemented circuit is wideband (0.05-1000 Hz), compatible with standard (Ag/AgCl) bio-potential electrodes, and dry (paste-less) textile electrodes. The circuit is also low power, requiring less than 50 mW (when powered at 12 V) per standard ECG lead (two channels required). It is therefore well suited for wearable, long-term applications.

[1]  André van Schaik,et al.  Non-invasive Electronic Biosensor Circuits and Systems , 2010 .

[2]  Robert Plonsey,et al.  Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields , 1995 .

[3]  L. Kirkup,et al.  A direct comparison of wet, dry and insulating bioelectric recording electrodes. , 2000, Physiological measurement.

[4]  H. Calkins Radiofrequency catheter ablation of supraventricular arrhythmias , 2001, Heart.

[5]  O. Aquilina,et al.  A brief history of cardiac pacing , 2006, Images in paediatric cardiology.

[6]  Metin Akay,et al.  Wiley encyclopedia of biomedical engineering , 2006 .

[7]  P. Bifulco,et al.  Mobile biomedical sensing with dry electrodes , 2008, 2008 International Conference on Intelligent Sensors, Sensor Networks and Information Processing.

[8]  I.K. Duskalov,et al.  Developments in ECG acquisition, preprocessing, parameter measurement, and recording , 1998, IEEE Engineering in Medicine and Biology Magazine.

[9]  André van Schaik,et al.  Giga-Ohm High-Impedance FET Input Amplifiers for Dry Electrode Biosensor Circuits and Systems , 2011 .

[10]  Paolo Bifulco,et al.  Towards true unipolar bio-potential recording: a preliminary result for ECG. , 2013, Physiological measurement.

[11]  John D. Enderle,et al.  Introduction to Biomedical Engineering , 1999 .

[12]  Maria Romano,et al.  An ultra-high input impedance ECG amplifier for long-term monitoring of athletes , 2010, Medical devices.

[13]  John E Madias,et al.  On Recording the Unipolar ECG Limb Leads via the Wilson's vs the Goldberger's Terminals: aVR, aVL, and aVF Revisited , 2008, Indian pacing and electrophysiology journal.

[14]  André van Schaik,et al.  A new EEG recording system for passive dry electrodes , 2010, Clinical Neurophysiology.

[15]  Andre van Schaik,et al.  Wearable dry sensors with bluetooth connection for use in remote patient monitoring systems. , 2010, Studies in health technology and informatics.

[16]  T. D. Clark,et al.  An ultra-low-noise electrical-potential probe for human-body scanning , 2000 .