Current state of knowledge on the behavior of steel liners in concrete containments subjected to overpressurization loads

In the United States, concrete containment buildings for commercial nuclear power plants have steel liners that act as the intemal pressure boundary. The liner abuts the concrete, acting as the interior concrete form. The liner is attached to the concrete by either studs or by a continuous structural shape (such as a T-section or channel) that is either continuously or intermittently welded to the liner. Studs are commonly used in reinforced concrete containments, while prestressed containments utilize a structural element as the anchorage. The practice in some countries follows the US practice, while in other countries the containment does not have a steel liner. In this latter case, there is a true double containment, and the annular region between the two containments is vented. This paper will review the practice of design of the liner system prior to the consideration of severe accident loads (overpressurization loads beyond the design conditions).

[1]  D. M. Schultz,et al.  Tension Tests of Containment Wall Isolated Liner Plates , 1984 .

[2]  T. P. Kicher,et al.  Design Selection of Patterns and Spacings for Stud Anchors used on Liner Shells , 1976 .

[3]  Kenneth P. Buchert Structural Performance Predictions for Liner Plates on Nuclear Facilities , 1984 .

[4]  D. S. Horschel Experimental results from pressure testing a 1:6-scale nuclear power plant containment , 1992 .

[5]  Y. R. Rashid,et al.  A probabilistic approach for predicting concrete containment leakage , 1993 .

[6]  M. B. Parks,et al.  Containment performance experiments under severe accident loadings , 1991 .

[7]  J. R. Weatherby,et al.  Investigation of liner tearing near penetrations in a reinforced concrete containment under severe accident loads , 1989 .

[8]  B. L. Spletzer,et al.  Separate effects testing to investigate liner tearing of the 1:6-scale reinforced concrete containment building , 1993 .

[9]  Joseph J. Ucciferro Structural Engineering in Nuclear Facilities , 1984 .

[10]  D. B. Clauss,et al.  Round-robin pretest analyses of a 1:6-scale reinforced concrete containment model subject to static internal pressurization , 1987 .

[11]  T. E. Johnson,et al.  Containment Liner Plate Anchors and Steel Embedments Test Results , 1977 .

[12]  Xxyyzz Structural Design of Nuclear Plant Facilities , 1976 .

[13]  M. B. Parks,et al.  Analyses of separate effects tests for liner tearing in the 1:6 scale model of a reinforced concrete containment building , 1993 .

[14]  T. E. Johnson,et al.  Containment building liner plate design report. , 1972 .

[15]  W. A. von Riesemann,et al.  Summary of NRC-sponsored research on containment integrity , 1990 .