Cardiac stimulation with high voltage discharge from stun guns

The ability of an electrical discharge to stimulate the heart depends on the duration of the pulse, the voltage and the current density that reaches the heart. Stun guns deliver very short electrical pulses with minimal amount of current at high voltages. We discuss external stimulation of the heart by high voltage discharges and review studies that have evaluated the potential of stun guns to stimulate cardiac muscle. Despite theoretical analyses and animal studies which suggest that stun guns cannot and do not affect the heart, 3 independent investigators have shown cardiac stimulation by stun guns. Additional research studies involving people are needed to resolve the conflicting theoretical and experimental findings and to aid in the design of stun guns that are unable to stimulate the heart.

[1]  P. Diamantopoulos,et al.  Electromagnetic modelling of current flow in the heart from TASER devices and the risk of cardiac dysrhythmias , 2007, Physics in medicine and biology.

[2]  Mark Kroll,et al.  Crafting The Perfect Shock , 2007, IEEE Spectrum.

[3]  K. Nagy,et al.  Neuromuscular effects of stun device discharges. , 2007, The Journal of surgical research.

[4]  R. Ideker,et al.  Can the Direct Cardiac Effects of the Electric Pulses Generated by the TASER X26 Cause Immediate or Delayed Sudden Cardiac Arrest in Normal Adults? , 2007, The American journal of forensic medicine and pathology.

[5]  K. Nagy,et al.  Acute effects of TASER X26 discharges in a swine model. , 2007, The Journal of trauma.

[6]  L. Saxon,et al.  Taser‐Induced Rapid Ventricular Myocardial Capture Demonstrated by Pacemaker Intracardiac Electrograms , 2007, Journal of cardiovascular electrophysiology.

[7]  K. Nagy,et al.  Repeated thoracic discharges from a stun device. , 2007, The Journal of trauma.

[8]  Dhanunjaya R. Lakkireddy,et al.  Effects of cocaine intoxication on the threshold for stun gun induction of ventricular fibrillation. , 2006, Journal of the American College of Cardiology.

[9]  E. Downar,et al.  Cardiac electrophysiological consequences of neuromuscular incapacitating device discharges. , 2006, Journal of the American College of Cardiology.

[10]  T. Chan,et al.  Cardiac monitoring of human subjects exposed to the taser. , 2006, The Journal of emergency medicine.

[11]  A. O'Rourke,et al.  Can Tasers® directly cause ventricular fibrillation? , 2006 .

[12]  J. Strote,et al.  Taser Use in Restraint-Related Deaths , 2006, Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors.

[13]  W. Franklin,et al.  Ventricular fibrillation after stun-gun discharge. , 2005, The New England journal of medicine.

[14]  J. Brewer,et al.  Cardiac Safety of Neuromuscular Incapacitating Defensive Devices , 2005, Pacing and clinical electrophysiology : PACE.

[15]  R. Shannon,et al.  Role of Cardiac Nerves in the Cardiovascular Response to Cocaine in Conscious Dogs , 2001, Circulation.

[16]  G. Todd,et al.  Acute cardiotoxic effects of cocaine and a hyperadrenergic state in anesthetized dogs. , 1994, International journal of cardiology.

[17]  B B Lerman,et al.  Relation between transcardiac and transthoracic current during defibrillation in humans. , 1990, Circulation research.

[18]  O. Z. Roy,et al.  Tests on a shocking device—the stun gun , 1989, Medical and Biological Engineering and Computing.

[19]  L A Geddes,et al.  Choice of the Optimum Pulse Duration for Precordial Cardiac Pacing: A Theoretical Study , 1985, Pacing and clinical electrophysiology : PACE.

[20]  L A Geddes,et al.  Myocardial Stimulation with Ultrashort Duration Current Pulses , 1982, Pacing and clinical electrophysiology : PACE.

[21]  W Irnich,et al.  The Chronaxie Time and Its Practical Importance , 1980, Pacing and clinical electrophysiology : PACE.

[22]  B J Blain,et al.  Home Office Police Scientific Development Branch , 1979 .

[23]  Carl J. Wiggers,et al.  The Mechanism and Nature of Ventricular Fibrillation , 1940 .

[24]  H. A. Blair ON THE INTENSITY-TIME RELATIONS FOR STIMULATION BY ELECTRIC CURRENTS. I , 1932, The Journal of general physiology.

[25]  T. Chan,et al.  Twelve-lead electrocardiogram monitoring of subjects before and after voluntary exposure to the Taser X26. , 2008, The American journal of emergency medicine.

[26]  D. Panescu,et al.  Finite Element Modeling of Electric Field Effects of TASER Devices on Nerve and Muscle , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[27]  D. Panescu,et al.  Cardiac Current Density Distribution by Electrical Pulses from TASER devices , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[28]  L. Hirsch Competing interests: none declared. , 2006 .

[29]  R. Lee,et al.  Biophysical injury mechanisms in electrical shock trauma. , 2000, Annual review of biomedical engineering.

[30]  G. Weiss Sur la possibilite de rendre comparables entre eux les appareils servant a l'excitation electrique. , 1990 .