A Grangeat‐type half‐scan algorithm for cone‐beam CT

Modern CT and micro-CT scanners are rapidly moving from fan-beam toward cone-beam geometry. Half-scan CT algorithms are advantageous in terms of temporal resolution, and widely used in fan-beam and cone-beam geometry. While existing half-scan algorithms for cone-beam CT are in the Feldkamp framework, in this paper we compensate missing data explicitly in the Grangeat framework, and formulate a half-scan algorithm in the circular scanning case. The half-scan spans 180° plus two cone angles that guarantee sufficient data for reconstruction of the midplane defined by the source trajectory. The smooth half-scan weighting functions are designed for the suppression of data inconsistency. Numerical simulation results are reported for verification of our formulas and programs. This Grangeat-type half-scan algorithm produces excellent image quality, without off-mid-plane artifacts associated with Feldkamp-type half-scan algorithms. The Grangeat-type half-scan algorithm seems promising for quantitative and dynamic biomedical applications of CT and micro-CT.

[1]  G Wang,et al.  Helical CT image noise--analytical results. , 1993, Medical physics.

[2]  R. Marr,et al.  On Two Approaches to 3D Reconstruction in NMR Zeugmatography , 1981 .

[3]  Rolf Clackdoyle,et al.  A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection , 1994, IEEE Trans. Medical Imaging.

[4]  Bruce D. Smith Image Reconstruction from Cone-Beam Projections: Necessary and Sufficient Conditions and Reconstruction Methods , 1985, IEEE Transactions on Medical Imaging.

[5]  Y. Liu,et al.  Half-scan cone-beam CT fluoroscopy with multiple x-ray sources. , 2001, Medical physics.

[6]  S. Zhao,et al.  X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses , 2000, IEEE Transactions on Medical Imaging.

[7]  A. Katsevich Analysis of an exact inversion algorithm for spiral cone-beam CT. , 2002, Physics in medicine and biology.

[8]  G. Wang,et al.  A general cone-beam reconstruction algorithm , 1993, IEEE Trans. Medical Imaging.

[9]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[10]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[11]  Ge Wang,et al.  Grangeat-Type Helical Half-Scan CT Algorithm for Reconstruction of a Short Object , 2003 .

[12]  Ming Jiang,et al.  Convergence of the simultaneous algebraic reconstruction technique (SART) , 2003, Conference Record of Thirty-Fifth Asilomar Conference on Signals, Systems and Computers (Cat.No.01CH37256).

[13]  Ge Wang,et al.  Grangeat-type helical half-scan computerized tomography algorithm for reconstruction of a short object. , 2003, Medical physics.

[14]  Gengsheng Lawrence Zeng,et al.  A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography , 1992, IEEE Trans. Medical Imaging.

[15]  Gyuseong Cho,et al.  Artifacts associated with implementation of the Grangeat formula. , 2002, Medical physics.

[16]  P. Grangeat Mathematical framework of cone beam 3D reconstruction via the first derivative of the radon transform , 1991 .

[17]  Y. Liu,et al.  Half-scan cone-beam x-ray microtomography formula. , 2008, Scanning.

[18]  Ming Jiang,et al.  Convergence Studies on Iterative Algorithms for Image Reconstruction , 2003, IEEE Trans. Medical Imaging.

[19]  S. Deans The Radon Transform and Some of Its Applications , 1983 .

[20]  Dominic J. Heuscher,et al.  Image reconstruction from cone-beam data on a circular short-scan , 2002, SPIE Medical Imaging.

[21]  Ge Wang,et al.  Feldkamp-type cone-beam tomography in the wavelet framework , 2000, IEEE Transactions on Medical Imaging.

[22]  Bruce D Smith COMPUTER-AIDED TOMOGRAPHIC IMAGING FROM CONE-BEAM DATA , 1987 .

[23]  Ge Wang,et al.  Guest Editorial - Multirow Detector and Cone-Beam Spiral/Helical CT , 2000, IEEE Trans. Medical Imaging.