Impact of particle size and aerosolization time on the metabolic effect of an inhaled insulin aerosol.

The effects were compared of varying aerosol particle size and aerosolization time within each breath on the metabolic effect elicited by inhalation of a liquid insulin aerosol in comparison with that after subcutaneous injection (s.c.) of regular insulin. In this single-center, open-label euglycemic glucose clamp study, 13 healthy non-smoking subjects received five administrations of insulin in randomized order on separate study days, once by s.c. (0.15 U/kg of regular insulin) and four times by inhalation. Subjects inhaled 1.5 U/kg of liquid insulin aerosol administered by the Aerodose Insulin Inhaler (Aerogen Inc., Mountain View, CA) configured to deliver two aerosol particle sizes--fine [F, 4.4 +/- 0.3 microm (mean +/- SD)] or very fine (VF, 3.5 +/- 0.2 microm)--and two aerosolization times (aerosol released for the first 2 or 4 s after the start of each 5-s inhalation). Glucose infusion rate (GIR) values necessary to keep blood glucose concentrations constant at 5.0 mmol/L were determined over a 6-h period following insulin administration. After inhalation of insulin, the onset of action was substantially more rapid on all four inhalation study days than after s.c. insulin, and the time to maximal action [t(GIRmax) (min)] was reached earlier: F/2 s, 127 +/- 54; F/4 s, 128 +/- 55; VF/2 s, 158 +/- 91; VF/4 s, 132 +/- 72; s.c., 175 +/- 69 (P < 0.0001). The longer aerosolization time (4 vs. 2 s) resulted in higher maximal metabolic action [GIR(max) (mg/kg/min), F/4 s 8.1 +/- 3.6, VF/4 s 8.4 +/- 2.7 vs. F/2 s 6.6 +/- 2.4, VF/2 s 7.2 +/- 2.4 (P = 0.01 for 4 s vs. 2 s, grouped data)], total metabolic activity [area under the curve of GIR 0-6 h (g/kg), F/4 s 1.97 +/- 0.92, VF/4 s 2.14 +/- 0.86 vs. F/2 s 1.56 +/- 0.68, VF/2 s 1.78 +/- 0.60 (P = 0.01)], and relative biopotency [F/4 s 10.6 +/- 4.0%, VF/4 s 11.7% +/- 4.1% vs. F/2 s 8.5 +/- 3.2%, VF/2 s 9.7 +/- 2.4% (P = 0.01)]. None of these summary measures was significantly affected by particle size. No drug- or device-related adverse events were observed. This study shows that aerosolization time, but not particle size, in the ranges studied, had an impact on the metabolic effect elicited by inhaled insulin, allowing rational selection of delivery parameters for further clinical testing. Based on the observed biopotency and the rapid onset of action, inhalation of a liquid insulin aerosol generated by the Aerodose Insulin Inhaler shows promise for covering prandial insulin requirements.

[1]  Dolovich Ma Influence of inspiratory flow rate, particle size, and airway caliber on aerosolized drug delivery to the lung. , 2000 .

[2]  S. Mudaliar,et al.  Inhaled insulin using the AERx Insulin Diabetes Management System in healthy and asthmatic subjects. , 2003, Diabetes care.

[3]  R. Unger,et al.  Lipotoxicity of beta-cells in obesity and in other causes of fatty acid spillover. , 2001, Diabetes.

[4]  D. Pavia,et al.  Effects of various inhalation modes on the deposition of radioactive pressurized aerosols. , 1982, European journal of respiratory diseases. Supplement.

[5]  T. Martonen,et al.  Factors affecting the deposition of aerosolized insulin. , 2001, Diabetes technology & therapeutics.

[6]  A. McElduff,et al.  Pulmonary insulin administration using the AERx system: physiological and physicochemical factors influencing insulin effectiveness in healthy fasting subjects. , 2000, Diabetes technology & therapeutics.

[7]  M. Dolovich New propellant-free technologies under investigation. , 1999, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[8]  G. Coates,et al.  Estimation of pulmonary deposition of aerosol using gamma scintigraphy. , 1999, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[9]  Kim Cs Methods of calculating lung delivery and deposition of aerosol particles. , 2000 .

[10]  T. Quattrin Inhaled insulin: recent advances in the therapy of Type 1 and 2 diabetes , 2004, Expert opinion on pharmacotherapy.

[11]  王姮,et al.  Inhaled insulin , 2005 .

[12]  L. Heinemann,et al.  Absorption and metabolic effect of inhaled insulin: intrapatient variability after inhalation via the Aerodose insulin inhaler in patients with type 2 diabetes. , 2002, Diabetes care.

[13]  J. Patton Breathing life into protein drugs , 1998, Nature Biotechnology.

[14]  W. Cefalu,et al.  Inhaled Human Insulin Treatment in Patients with Type 2 Diabetes Mellitus , 2001, Annals of Internal Medicine.

[15]  C. Kim,et al.  Assessment of regional deposition of inhaled particles in human lungs by serial bolus delivery method. , 1996, Journal of applied physiology.

[16]  W. Cefalu,et al.  Efficacy of inhaled human insulin in type 1 diabetes mellitus: a randomised proof-of-concept study , 2001, The Lancet.

[17]  L. Heinemann,et al.  Time‐action Profile of the Insulin Analogue B28Asp , 1996, Diabetic medicine : a journal of the British Diabetic Association.

[18]  M. Ellmerer,et al.  Dose-response relation of liquid aerosol inhaled insulin in Type I diabetic patients , 2001, Diabetologia.