The qualitative comparative analysis of the visual field using computer assisted, semi-automated and manual instrumentation: III Clinical analysis

A comparative evaluation of the Octopus automated perimeter (Programmes 21 and 31), the Goldmann Bowl perimeter, the Bjerrum Screen and the Friedmann VFAs Mk I and Mk II was carried out on a heterogenous sample of 75 patients. Field loss was categorized using a modification of the classifications proposed by Greve (1982). The results were analysed using the Level 4 analysis developed by Flanagan, Wild, Barnes, Gilmartin, Good and Crews (1984a). The performance of the various test logics was found to differ between the categories of field defect.

[1]  H Bebie,et al.  STATIC PERIMETRY: ACCURACY AND FLUCTUATIONS , 1976, Acta ophthalmologica.

[2]  J. M. Wild,et al.  The qualitative comparative analysis of the visual field using computer assisted, semi-automated and manual instrumentation: I Scoring system , 2004, Documenta Ophthalmologica.

[3]  L. Gates,et al.  How important are peripheral fields. , 1959, A.M.A. archives of ophthalmology.

[4]  John A. Mccrary,et al.  Computerized perimetry in neuro-ophthalmology. , 1979, Ophthalmology.

[5]  E. L. Greve,et al.  Performance of computer assisted perimeters , 1982, Documenta Ophthalmologica.

[6]  J. Flanagan,et al.  The qualitative comparative analysis of the visual field using computer assisted, semi-automated and manual instrumentation: II Statistical analysis , 2004, Documenta Ophthalmologica.

[7]  A. Friedmann Serial analysis of changes in visual field defects, employing a new instrument, to determine the activity of diseases involving the visual pathways. , 1966, Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde.

[8]  H. M. Traquair,et al.  An Introduction to Clinical Perimetry , 1943, The Indian Medical Gazette.

[9]  U. Schmied Automatic (Octopus) and manual (Goldmann) perimetry in glaucoma , 2004, Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie.

[10]  H Bebie,et al.  STATIC PERIMETRY: STRATEGIES , 1976, Acta ophthalmologica.

[11]  E. Gramer,et al.  Detectability of Early Glaucomatous Field Defects , 1981 .

[12]  A Heijl,et al.  A clinical comparison of three computerized automatic perimeters in the detection of glaucoma defects. , 1981, Archives of ophthalmology.

[13]  G. Sedman Being an Epileptic , 1966 .

[14]  E. Greve Visual field analyser and threshold. , 1971, The British journal of ophthalmology.

[15]  G. Spaeth,et al.  Clinical experiences with the use of an automated perimeter (Octopus) in the diagnosis and management of patients with glaucoma and neurologic diseases. , 1979, Ophthalmology.