Clocked quantum-dot cellular automata devices: experimental studies

Presents an experimental demonstration of two novel clocked QCA devices - a QCA latch and a QCA shift register. We demonstrate the operation of the devices, and discuss sources and methods of lowering the digital errors in QCA clocked devices.

[1]  C. Lent,et al.  Realization of a Functional Cell for Quantum-Dot Cellular Automata , 1997 .

[2]  Konstantin K. Likharev,et al.  Single-Electron Parametron: Reversible Computation in a Discrete-State System , 1996, Science.

[3]  Konstantin K. Likharev,et al.  Single-Electron Parametron , 1998, VLSI Design.

[4]  Williams,et al.  Quantum limitation on Coulomb blockade observed in a 2D electron system. , 1993, Physical review letters.

[5]  Dolan,et al.  Observation of single-electron charging effects in small tunnel junctions. , 1987, Physical review letters.

[6]  A. N. Korotkov,et al.  SINGLE-ELECTRON-PARAMETRON-BASED LOGIC DEVICES , 1998 .

[7]  P. D. Tougaw,et al.  A device architecture for computing with quantum dots , 1997, Proc. IEEE.

[8]  Konstantin K. Likharev,et al.  Possible performance of capacitively coupled single‐electron transistors in digital circuits , 1995 .

[9]  R. Landauer Is quantum mechanics useful , 1995 .

[10]  G. Tóth,et al.  QUASIADIABATIC SWITCHING FOR METAL-ISLAND QUANTUM-DOT CELLULAR AUTOMATA , 1999, cond-mat/0004457.

[11]  A. A. Odintsov,et al.  Macroscopic quantum tunneling of the electric charge in small tunnel junctions , 1989 .

[12]  C. Lent,et al.  Power gain and dissipation in quantum-dot cellular automata , 2002 .

[13]  Gary H. Bernstein,et al.  Experimental demonstration of clocked single-electron switching in quantum-dot cellular automata , 2000 .

[14]  Snider,et al.  Digital logic gate using quantum-Dot cellular automata , 1999, Science.