Testing Methods for Measuring the Effects of Stray Capacitances on High-Voltage Current Transformers

This paper evaluates different measuring systems to estimate the effect of stray capacitances between primary and secondary windings on current transformers (CTs) used in high-voltage power networks. All windings are at nearly ground potential during laboratory calibration because this is the typical configuration for almost all CT's calibration systems. However, in service, the primary winding is at high potential, so that additional currents flow through the load due to stray capacitances between primary and secondary windings, even if the CT has an electrostatic shield for reducing these capacitances. This effect changes the CT errors determined at no potential. Experimental determination of the variation of ratio and phase displacement errors between both working conditions is evaluated for a set of different CTs using different measuring systems. These systems include from the simplest low-voltage bridge capacitance measurement to the most complex one that simultaneously applies current and voltage.

[1]  T. R. Foord,et al.  Leakage Inductance and Interwinding Capacitance in Toroidal Ratio Transformers , 1967 .

[2]  Gonzalo Aristoy,et al.  Effects of stray capacitances on high voltage current transformers , 2014, 2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings.

[3]  Daniel Slomovitz,et al.  Error compensation of capacitive effects in current transformers , 2012, 2012 Conference on Precision electromagnetic Measurements.

[4]  D. Slomovitz,et al.  On-line calibration of high voltage current transformers , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.

[5]  Réjean Arseneau,et al.  A Current-Comparator-Based System For Calibrating High-Voltage Current Transformers Under Actual Operating Conditions , 2011, IEEE Transactions on Instrumentation and Measurement.

[6]  Branislav Djokic,et al.  An Optically Isolated Hybrid Two-Stage Current Transformer for Measurements at High Voltage , 2005, IMTC 2005.

[7]  Warren H. Cook,et al.  - Instrument Transformers , 1970, The Electric Power Engineering Handbook - Five Volume Set.

[8]  N. L. Kusters,et al.  The effect of winding potentials on current transformer errors , 1962, Transactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics.

[9]  A.H.M. Arnold The effect of capacitance on the design of toroidal current-transformers , 1950 .

[10]  Jari K. Hällström,et al.  Onsite Calibration of a Current Transformer Using a Rogowski Coil , 2009, IEEE Transactions on Instrumentation and Measurement.