Evoked Electromyographic Technique for Quantitative Assessment of the Innervation Status of Laryngeal Muscles

Objectives: The purpose of this study was to develop a minimally invasive, noninjurious evoked electromyographic technique that could accurately quantitate the level of innervation of laryngeal muscles with recurrent laryngeal nerve stimulation. Methods: A four-phase study was conducted in 24 canines, including 1) identification of the best stimulation-recording configuration, 2) statistical analysis of sensitivity and accuracy, 3) evaluation of safety, and 4) identification of the laryngeal muscle(s) that contribute to the evoked response. Results: The results demonstrated that an entirely noninvasive technique is not feasible. The stimulating cathode must be invasive to ensure discrete activation of the recurrent laryngeal nerve, whereas both recording electrodes should remain on the surface with one overlying the thyroid ala. This configuration proved to be highly accurate, with an error rate of only 6% to 7%, and with sensitivity sufficient to detect a signal in a nerve with fewer than 1% of the axons intact. There was no evidence of nerve injury in any animal over the course of 350 stimulus needle penetrations. By use of neuromuscular blockade to identify those muscles generating the surface response, the thyroarytenoid muscle was found to be the primary contributor, whereas the posterior cricoarytenoid muscle was uninvolved. Conclusions: This evoked electromyographic technique could provide quantitative information regarding the extent of muscle innervation during denervation and regeneration in case of laryngeal paralysis.

[1]  C. Billante,et al.  Neurophysiology of vocal fold paralysis. , 2004, Otolaryngologic clinics of North America.

[2]  G. Berke,et al.  Lack of Evoked Laryngeal Electromyography Response in Patients with a Clinical Diagnosis of Vocal Cord Paralysis , 2001, The Annals of otology, rhinology, and laryngology.

[3]  A. Hillel The Study of Laryngeal Muscle Activity in Normal Human Subjects and in Patients With Laryngeal Dystonia Using Multiple Fine‐Wire Electromyography , 2001, The Laryngoscope.

[4]  Anjum S Khan,et al.  Clinical evoked electromyography for recurrent laryngeal nerve preservation: Use of an endotracheal tube electrode and a postcricoid surface electrode , 1998, The Laryngoscope.

[5]  A. Khan,et al.  Experience with two types of electromyography monitoring electrodes during thyroid surgery. , 1997, American journal of otolaryngology.

[6]  C. Ludlow,et al.  Assessing the Clinical Utility of the Magnetic Stimulator for Measuring Response Latencies in the Laryngeal Muscles , 1996, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[7]  S. McMahon,et al.  The consequences of microneurography electrode-induced injury of peripheral nerves observed in the rat and man , 1994, Pain.

[8]  M. Hallett,et al.  Limitations of Electromyography and Magnetic Stimulation for Assessing Laryngeal Muscle Control , 1994, The Annals of otology, rhinology, and laryngology.

[9]  Patrick D. Wall,et al.  The electrophysiological consequences of electrode impalement of peripheral nerves in the rat , 1993, Brain Research.

[10]  W. Thumfart,et al.  Electrophysiologic Investigation of Lower Cranial Nerve Diseases by Means of Magnetically Stimulated Neuromyography of the Larynx , 1992, The Annals of otology, rhinology, and laryngology.

[11]  N. J. Coker Facial electroneurography: Analysis of techniques and correlation with degenerating motoneurons , 1992, The Laryngoscope.

[12]  P. Flint,et al.  Laryngeal Synkinesis following Reinnervation in the Rat: Neuroanatomic and Physiologic Study Using Retrograde Fluorescent Tracers and Electromyography , 1991, The Annals of otology, rhinology, and laryngology.

[13]  S. Schaefer,et al.  Laryngeal electromyography. , 1991, Otolaryngologic clinics of North America.

[14]  R. Crumley Laryngeal Synkinesis: Its Significance to the Laryngologist , 1989, The Annals of otology, rhinology, and laryngology.

[15]  S. Kuna,et al.  Thyroarytenoid muscle activity during wakefulness and sleep in normal adults. , 1988, Journal of applied physiology.

[16]  R. Wiet,et al.  A statistical study of ENoG test error , 1988, The Laryngoscope.

[17]  G. Herzon,et al.  Evoked accelerometry: A sensitive and accurate method for evaluating facial nerve function using a portable device , 1988, The Laryngoscope.

[18]  W. Thumfart Electromyography of the larynx and related technics. , 1986, Acta oto-rhino-laryngologica Belgica.

[19]  U. Fisch Prognostic value of electrical tests in acute facial paralysis. , 1984, The American journal of otology.

[20]  W. Thumfart,et al.  Die Elektroneurographie der Kehlkopfnerven mittels lupenendoskopischer EMG-Ableitung aus dem Kehlkopf des wachen Patienten* , 1980 .

[21]  W. Thumfart,et al.  [Electroneurography of the laryngeal nerves in the awake patient using electromyography of the larynx under zoom-endoscopic-control (author's transl)]. , 1980, Laryngologie, Rhinologie, Otologie.

[22]  I. Satoh Evoked electromyographic test applied for recurrent laryngeal nerve paralysis , 1978, The Laryngoscope.

[23]  E. Esslen Electromyography and electroneurography , 1977 .