A novel topology for enhancing the Low Voltage Ride through capability for grid connected wind turbine generators

Energy shortage and environmental pollution have led to the increasing demand of using renewable sources for electricity production. Currently, power generation from wind energy systems (WES) is of global significance and will continue to grow during the coming years leading to concerns about power system stability where wind farms replace conventional generating technologies that use fossil fuels as the primary energy source. One of these concerns is Low-Voltage Ride-Through (LVRT). In this paper, a novel topology based on the use of magnetic amplifier for enhancing the LVRT capability for grid connected permanent magnet synchronous generators (PMSG) is presented. The system performance is investigated using Matlab.

[1]  Z.A. Styczynski,et al.  Dynamic simulation of renewable energy sources and requirements on fault ride through behavior , 2006, 2006 IEEE Power Engineering Society General Meeting.

[2]  O Abdel-Baqi,et al.  Series Voltage Compensation for DFIG Wind Turbine Low-Voltage Ride-Through Solution , 2011, IEEE Transactions on Energy Conversion.

[3]  Zhe Chen,et al.  A Review of the State of the Art of Power Electronics for Wind Turbines , 2009, IEEE Transactions on Power Electronics.

[4]  P. D. Atkinson,et al.  A theoretical and experimental study of the series-connected magnetic amplifier , 1949 .

[5]  Hai-Jiao Guo,et al.  A novel algorithm for fast and efficient maximum power point tracking of wind energy conversion systems , 2008, 2008 18th International Conference on Electrical Machines.

[6]  Carroll W. Lufcy A Survey of Magnetic Amplifiers , 1955, Proceedings of the IRE.

[7]  Ching-Tsai Pan,et al.  A Novel Sensorless MPPT Controller for a High-Efficiency Microscale Wind Power Generation System , 2010, IEEE Transactions on Energy Conversion.

[8]  Honghua Xu,et al.  A Survey on Recent Low Voltage Ride-Through Solutions of Large Scale Wind Farm , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[9]  Peng Zhou,et al.  Analysis of the by-pass resistance of an active crowbar for doubly-fed induction generator based wind turbines under grid faults , 2008, 2008 International Conference on Electrical Machines and Systems.

[10]  M. Rafian,et al.  Superconducting power-system transductor , 1981 .

[11]  K. Tan,et al.  Optimum control strategies in energy conversion of PMSG wind turbine system without mechanical sensors , 2004, IEEE Transactions on Energy Conversion.

[12]  Xiao-Ping Yang,et al.  Low Voltage Ride-Through of Directly Driven Wind Turbine with Permanent Magnet Synchronous Generator , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[13]  R. Miceli,et al.  Active power maximizing for Wind Electrical Energy Generating Systems moved by a Modular Multiple Blade Fixed Pitch Wind Turbine , 2008, 2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion.

[14]  M. Sawada,et al.  A Magnetic Amplifier using nanocrystalline soft magnetic material , 2011, 8th International Conference on Power Electronics - ECCE Asia.

[15]  Xavier Roboam,et al.  Architecture Complexity and Energy Efficiency of Small Wind Turbines , 2007, IEEE Transactions on Industrial Electronics.

[16]  Kostas Kalaitzakis,et al.  Design of a maximum power tracking system for wind-energy-conversion applications , 2006, IEEE Transactions on Industrial Electronics.

[17]  L. L. Freris,et al.  Control policies for wind-energy conversion systems , 1981 .

[18]  Shao Zhang,et al.  Advanced Control of Series Voltage Compensation to Enhance Wind Turbine Ride Through , 2012, IEEE Transactions on Power Electronics.

[19]  Bin Wu,et al.  Unified Power Control for PMSG-Based WECS Operating Under Different Grid Conditions , 2011, IEEE Transactions on Energy Conversion.

[20]  R. Feinberg,et al.  A review of transductor principles and applications , 1950 .

[21]  Shigeo Morimoto,et al.  Sensorless output maximization control for variable-speed wind generation system using IPMSG , 2003 .

[22]  Scott D. Sudhoff,et al.  Analysis of Electric Machinery and Drive Systems , 1995 .

[23]  Ahmed Massoud,et al.  Unified power flow controller for low voltage ride through capability of wind-based renewable energy grid-connected systems , 2011, Eighth International Multi-Conference on Systems, Signals & Devices.

[24]  A. Uno Lamm Some Fundamentals of a Theory of the Transductor or Magnetic Amplifier , 1947, Transactions of the American Institute of Electrical Engineers.

[25]  Bin Wu,et al.  Comparison of Stabilization Methods for Fixed-Speed Wind Generator Systems , 2010, IEEE Transactions on Power Delivery.

[26]  J. F. Conroy,et al.  Low-voltage ride-through of a full converter wind turbine with permanent magnet generator , 2007 .

[27]  F. M. Hughes,et al.  Fault ride through of fully rated converter wind turbines with AC and DC transmission systems , 2009 .

[28]  D. Jovcic,et al.  Dynamic Modelling, Simulation and Analysis of an Offshore Variable-Speed Directly-Driven Permanent-Magnet Wind Energy Conversion and Storage System (WECSS) , 2007, OCEANS 2007 - Europe.

[29]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .