Design and Operation of Optical Fiber for Mass Measuring Instrument with Bending Power Loss Principle

Utilization fiber optics macro-bending will be useful for non-destructive applications, such as a mass measurement device. This research, therefore, analyzes the fiber optic power loss due to macro bending by mass loading and explores its possible application as an instrument of mass scale. A single-mode fiber (SMF) with a core diameter of 8.2μm and laser with a wavelength of 1310 nm and 1550 nm are used in this  work. Moreover, an optical power meter with a sensitivity of 0.01dBm is applied as the detector while power loss is determined using nine bending cylinders that can produce eighteen bends with a roundtrip system. It is  obtaineda correlation coefficient R 2 of 0.9910 and 0.9959 corresponding to a sigmoid of 4 parameters for two-wavelength sources of 1310nm and 1550nm, respectively. The results showed mass suppression can produce a power loss with a relatively small error of 19.60%, 11.23%, 0.20%, 3.74%, and 9.36% for mass 300g, 600g, 100 g, 1400g, and 1800g, respectively

[1]  Feng Han,et al.  Optical Fiber MEMS Micro Pressure Sensor Based On Beam-membrane Structure , 2019, 2019 IEEE 14th International Conference on Nano/Micro Engineered and Molecular Systems (NEMS).

[2]  Linbing Wang,et al.  An investigation in the influence of helical structure on bend loss of pavement optical fiber sensor , 2019, Optik.

[3]  Shijie Fu,et al.  Theoretical investigation of mode competition in high-power fiber lasers and amplifiers at 1018nm , 2018, Other Conferences.

[4]  V. Supradeepa,et al.  High power, high efficiency, continuous-wave supercontinuum generation using standard telecom fibers. , 2017, Optics express.

[5]  Jae-Kyung Pan,et al.  Intensity-Based Fiber Optic Sensor Head Characteristic Using Twist Dual Cycling Bending Loss , 2017 .

[6]  Tomi Budi Waluyo,et al.  Design of micro bending deformer for optical fiber weight sensor , 2017 .

[7]  S. Kadhim,et al.  Performance Evaluation of Experimental Digital Optical Fiber Communication Link , 2017 .

[8]  Yong Zhao,et al.  Design and experiment of an optical fiber micro bend sensor for respiration monitoring , 2016 .

[9]  Abebaw Abun Amanu Macro Bending Losses in Single Mode Step Index Fiber , 2016 .

[10]  P. Yupapin,et al.  Design of Mach-Zehnder interferometer and ring resonator for biochemical sensing , 2015 .

[11]  Saktioto,et al.  Birefringence analysis of directional fiber coupler induced by fusion and coupling parameters , 2013 .

[12]  Sulaiman Wadi Harun,et al.  Fibre Optic Sensors for Selected Wastewater Characteristics , 2013, Sensors.

[13]  Mekuanin Lemlem,et al.  Investigation of the Effects of Macro Bending Loss on Step index Single Mode Fiber , 2012 .

[14]  Claudio Floridia,et al.  Optical fiber sensor for pressure measurement based on elastomeric membrane and macrobending loss , 2012, Photonics Europe.

[15]  M. A. Jalil,et al.  Development of FBG sensing system for outdoor temperature environment , 2011 .

[16]  J. Ali,et al.  Photon trapping model within a fiber Bragg grating for dynamic optical tweezers use , 2010 .

[17]  A. Teixeira,et al.  Modeling of Bend Losses in Single-Mode Optical Fibers , 2009 .

[18]  Jalil Ali,et al.  Modeling of coupling coefficient as a function of coupling ratio , 2008, International Symposium on Laser Metrology.

[19]  B. Tahir,et al.  A study of FBG sensor and electrical strain gauge for strain measurements , 2008 .

[20]  J. H. Cole,et al.  Improved Bend Loss Formula Verified for Optical Fiber by Simulation and Experiment , 2007, IEEE Journal of Quantum Electronics.

[21]  Dennis Derickson,et al.  Fiber optic test and measurement , 1998 .