A comparative finite element study of condylar fixation: preliminary results

The basis for fixation of condylar fractures is strongly determined by surgical decision using available technology. Recent developments of technology include the retrograde distal femoral nail (DFN), with condylar "bolts" (T2 SCN), and along with the dynamic condylar screw (DCS) and various combinations of additional screws and wire, these devices form the primary elements available for fracture fixation. This paper looks at the relative structural performance of these constructs under the action of an idealised loading condition -- axial load through the femoral head in line with the mechanical (c.f. anatomical) axis of the femur. The finite element method is used. The geometric models have been created using available published information, and meshing generated using tetrahedral elements. Some reasonable assumptions about the properties of cortical and cancellous bone have been made. The effect of good quality and poor quality cancellous bone has been considered. The results show the displacements of each device and some of the key stressed regions using each construct principle. The use of condylar bolts produces significant levels of stress within the bone before any patient-load is applied, but provides a stiffer construct for subsequent loading. Surgeons will make their own decisions about the appropriate construct for each patient, but this evaluation is intended to help with that decision making.

[1]  J. K. Spelt,et al.  Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading. , 2004, Medical engineering & physics.

[2]  C. Roberts,et al.  Mechanical Study of the Safe Distance Between Distal Femoral Fracture Site and Distal Locking Screws in Antegrade Intramedullary Nailing , 2005, Journal of orthopaedic trauma.

[3]  S Houshian,et al.  The retrograde nail for distal femoral fractures in the elderly: high failure rate of the condyle screw and nut. , 2006, Injury.

[4]  H. Janzing,et al.  The retrograde intramedullary supracondylar nail: an alternative in the treatment of distal femoral fractures in the elderly? , 1998, Archives of Orthopaedic and Trauma Surgery.

[5]  K. Leung,et al.  Interlocking intramedullary nailing for supracondylar and intercondylar fractures of the distal part of the femur. , 1991, The Journal of bone and joint surgery. American volume.

[6]  Maurice E. Muller,et al.  The Comprehensive Classification of Fractures of Long Bones , 1990 .

[7]  E Y Chao,et al.  Internal forces and moments in the femur during walking. , 1997, Journal of biomechanics.

[8]  J. Delee,et al.  Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw. , 1982, The Journal of bone and joint surgery. American volume.

[9]  F. Ali,et al.  Treatment of isolated complex distal femoral fractures by external fixation. , 2000, Injury.

[10]  K. Ito,et al.  Internal fixation of supracondylar femoral fractures: comparative biomechanical performance of the 95-degree blade plate and two retrograde nails. , 1998, Journal of orthopaedic trauma.

[11]  J. Cegoñino,et al.  A Comparative Analysis of Different Treatments for Distal Femur Fractures using the Finite Element Method , 2004, Computer methods in biomechanics and biomedical engineering.

[12]  R. Brumback,et al.  Intramedullary nailing of femoral shaft fractures. Part II: Fracture-healing with static interlocking fixation. , 1988, The Journal of bone and joint surgery. American volume.