Validation of a Feedback-Controlled Elbow Simulator Design: Elbow Muscle Moment Arm Measurement

The Allegheny General Hospital (AGH) elbow simulator was designed to be a closed-loop physiologic simulator actuating movement in cadaveric elbow specimens via servoelectric motors that attach to the tendons of the biceps, brachialis, triceps, and pronator teres muscles. A physiologic elbow simulator should recreate the appropriate moment arms throughout the elbow's range of motion. To validate this design goal, muscle moment arms were measured in three cadaver elbow specimens using the simulator. Flexion-extension moment arms of four muscles were measured at three different pronation/supination angles: fully pronated, fully supinated, and neutral; pronation-supination moment arms were measured at three different flexion-extension angles: 30 deg, 60 deg, and 90 deg. The tendon-displacement method was used in these measurements, in which the ratio of the change in musculotendon length to the change in joint angle was computed. The numeric results compared well with those previously reported; the biceps and pronator teres flexion-extension moment arms varied with pronation-supination position, and vice versa. This is one of the few reports of both flexion-extension and pronation-supination moment arms in the same specimens, and represents the first use of closed-loop feedback control in the AGH elbow simulator. The simulator is now ready for use in clinical studies such as in analyses of radial head replacement and medial ulnar collateral ligament repair. Copyright © 2009 by ASME.

[1]  R. Waters,et al.  The relationship of the interosseous membrane to the axis of rotation of the forearm. , 1994, Clinical orthopaedics and related research.

[2]  A G Feldman,et al.  Moment arms and lengths of human upper limb muscles as functions of joint angles. , 1996, Journal of biomechanics.

[3]  N. Sharkey,et al.  A dynamic cadaver model of the stance phase of gait: performance characteristics and kinetic validation. , 1998, Clinical biomechanics.

[4]  S. Delp,et al.  Scaling of peak moment arms of elbow muscles with upper extremity bone dimensions. , 2002, Journal of biomechanics.

[5]  A. Seireg,et al.  Biochemical Analysis Of The Musculoskeletal Structure For Medicine And Sports , 1989 .

[6]  C E Dunning,et al.  Simulation of elbow and forearm motion in vitro using a load controlled testing apparatus. , 2000, Journal of biomechanics.

[7]  K. An,et al.  Mechanical advantage of the thumb muscles. , 1998, Journal of biomechanics.

[8]  D. Dowson,et al.  Analysis of elbow forces due to high-speed forearm movements. , 1980, Journal of biomechanics.

[9]  R E Barr,et al.  Development and evaluation of a musculoskeletal model of the elbow joint complex. , 1996, Journal of biomechanical engineering.

[10]  A J Petrella,et al.  The effect of component placement on knee kinetics after arthroplasty with an unconstrained prosthesis , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  R. L. Linscheid,et al.  Muscles across the elbow joint: a biomechanical analysis. , 1981, Journal of biomechanics.

[12]  P. Crago,et al.  A dynamic model for simulating movements of the elbow, forearm, an wrist. , 1996, Journal of biomechanics.

[13]  James A. Johnson,et al.  Single-strand reconstruction of the lateral ulnar collateral ligament restores varus and posterolateral rotatory stability of the elbow. , 2002, Journal of shoulder and elbow surgery.

[14]  James A. Johnson,et al.  Muscle Forces and Pronation Stabilize the Lateral Ligament Deficient Elbow , 2001, Clinical orthopaedics and related research.

[15]  G. Ettema,et al.  The moment arms of 23 muscle segments of the upper limb with varying elbow and forearm positions: Implications for motor control , 1998 .

[16]  E. Chao,et al.  A biomechanical study of normal functional elbow motion. , 1981, The Journal of bone and joint surgery. American volume.

[17]  W. Buford,et al.  Muscle balance at the knee--moment arms for the normal knee and the ACL-minus knee. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[18]  S. Delp,et al.  Variation of muscle moment arms with elbow and forearm position. , 1995, Journal of biomechanics.

[19]  Johnston Gw A follow-up of one hundred cases of fracture of the head of the radius with a review of the literature. , 1962 .

[20]  G R Johnson,et al.  Dynamics of the Upper Limb during Performance of the Tasks of Everyday Living—A Review of the Current Knowledge Base , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[21]  Philippe Favre,et al.  Moment arms of forearm rotators. , 2006, Clinical biomechanics.

[22]  F W Werner,et al.  Wrist joint motion simulator , 1996, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  James A. Johnson,et al.  Single-strand ligament reconstruction of the medial collateral ligament restores valgus elbow stability. , 2002, Journal of shoulder and elbow surgery.

[24]  Freddie H. Fu,et al.  A new dynamic testing apparatus to study glenohumeral joint motion. , 1995, Journal of biomechanics.

[25]  James A. Johnson,et al.  Metallic radial head arthroplasty improves valgus stability of the elbow. , 1999, Clinical orthopaedics and related research.

[26]  J. Conn,et al.  INJURIES OF THE ELBOW: A TEN YEAR REVIEW , 1961 .

[27]  K N An,et al.  Determination of muscle and joint forces: a new technique to solve the indeterminate problem. , 1984, Journal of biomechanical engineering.

[28]  James A. Johnson,et al.  Rehabilitation of the medial collateral ligament-deficient elbow: an in vitro biomechanical study. , 2000, The Journal of hand surgery.