Micro-organism extraction from biological samples using DEP forces enhanced by osmotic shock.

On the road towards efficient diagnostics of infectious diseases, sample preparation is considered as the key step and remains a real technical challenge. Finding new methods for extraction of micro-organisms from a complex biological sample remains a major challenge prior to pathogen detection and analysis. This paper reports a new technique for capturing and isolating micro-organisms from a complex sample. To achieve the segregation of pathogens and blood cells, dielectrophoretic forces applied to bioparticles previously subjected to an osmotic shock are successfully implemented within a dedicated microfluidic device. Our device involves an electrode array of interdigitated electrodes, coated with an insulating layer, to minimize electrochemical reactions with the electrolyte and to enable long-time use. The electric field intensity inside the device is optimized, considering the insulating layer, for a given frequency bandwidth, enabling the separation of bioparticles by dielectrophoretic forces. Our predictions are based on analytical models, consistent with numerical simulations (using COMSOL Multiphysics) and correlated to experimental results. The method and device have been shown to extract different types of micro-organisms spiked in a blood cell sample. We strongly believe that this new separation approach may open the way towards a simple device for pathogen extraction from blood and more generally complex samples, with potential advantages of genericness and simplicity.

[1]  M. Clementi,et al.  The Era of Molecular and Other Non-Culture-Based Methods in Diagnosis of Sepsis , 2010, Clinical Microbiology Reviews.

[2]  R. Goodacre,et al.  Discrimination of bacteria using surface-enhanced Raman spectroscopy. , 2004, Analytical chemistry.

[3]  Michael Schmitt,et al.  Chemotaxonomic Identification of Single Bacteria by Micro-Raman Spectroscopy: Application to Clean-Room-Relevant Biological Contaminations , 2005, Applied and Environmental Microbiology.

[4]  K. Dholakia,et al.  Microfluidic sorting in an optical lattice , 2003, Nature.

[5]  U. Zimmermann,et al.  Dielectric spectroscopy of Schizosaccharomyces pombe using electrorotation and electroorientation. , 2001, Biochimica et biophysica acta.

[6]  Mieke Uyttendaele,et al.  Alternative microbial methods: An overview and selection criteria. , 2010, Food microbiology.

[7]  Daniel Ahmed,et al.  Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW). , 2008, Lab on a chip.

[8]  P. Savelkoul,et al.  New developments in the diagnosis of bloodstream infections. , 2004, The Lancet. Infectious diseases.

[9]  Ronald Pethig,et al.  Selective dielectrophoretic confinement of bioparticles in potential energy wells , 1993 .

[10]  Yi Zhang,et al.  Continuous dielectrophoretic bacterial separation and concentration from physiological media of high conductivity. , 2011, Lab on a chip.

[11]  A. B. Frazier,et al.  Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations. , 2006, Lab on a chip.

[12]  J. Voldman Electrical forces for microscale cell manipulation. , 2006, Annual review of biomedical engineering.

[13]  Michael P Hughes,et al.  Strategies for dielectrophoretic separation in laboratory‐on‐a‐chip systems , 2002, Electrophoresis.

[14]  T. Maier,et al.  Direct bacterial profiling by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry for identification of pathogenic Neisseria. , 2009, The Journal of molecular diagnostics : JMD.

[15]  Thomas Laurell,et al.  Acoustofluidics 8: applications of acoustophoresis in continuous flow microsystems. , 2012, Lab on a chip.

[16]  H. Passow,et al.  Preparation and properties of human erythrocyte ghosts , 1973, Molecular and Cellular Biochemistry.

[17]  N. Pamme,et al.  Continuous sorting of magnetic cells via on-chip free-flow magnetophoresis. , 2006, Lab on a chip.

[18]  Mattias Goksör,et al.  Optical tweezers applied to a microfluidic system. , 2004, Lab on a chip.

[19]  H. Morgan,et al.  Electrohydrodynamics and dielectrophoresis in microsystems: scaling laws , 2003 .

[20]  Michael L Wilson,et al.  Update on detection of bacteremia and fungemia , 1997, Clinical microbiology reviews.

[21]  K. Kogure,et al.  Bacterial motility: links to the environment and a driving force for microbial physics. , 2006, FEMS microbiology ecology.

[22]  Ian P Thompson,et al.  Raman microscopic analysis of single microbial cells. , 2004, Analytical chemistry.

[23]  Thomas Laurell,et al.  Chip integrated strategies for acoustic separation and manipulation of cells and particles. , 2007, Chemical Society reviews.

[24]  H. Morgan,et al.  Ac electrokinetics: a review of forces in microelectrode structures , 1998 .

[25]  K. Jensen,et al.  Cells on chips , 2006, Nature.

[26]  D. Naumann,et al.  Identification of medically relevant microorganisms by vibrational spectroscopy. , 2002, Journal of microbiological methods.

[27]  Jonghyun Oh,et al.  Comprehensive analysis of particle motion under non-uniform AC electric fields in a microchannel. , 2009, Lab on a chip.

[28]  H. A. Pohl,et al.  Separation of Living and Dead Cells by Dielectrophoresis , 1966, Science.

[29]  Pavel Zemánek,et al.  Light at work: The use of optical forces for particle manipulation, sorting, and analysis , 2008, Electrophoresis.

[30]  H. Andersson,et al.  Microfluidic devices for cellomics: a review , 2003 .

[31]  Saeid Nahavandi,et al.  Dielectrophoretic platforms for bio-microfluidic systems. , 2011, Biosensors & bioelectronics.

[32]  J. Gimsa,et al.  A comprehensive approach to electro-orientation, electrodeformation, dielectrophoresis, and electrorotation of ellipsoidal particles and biological cells. , 2001, Bioelectrochemistry.