Ultrasonographic Assessment of the Flexor Pollicis Longus Tendon After Plate Fixation.

Rupture of the flexor pollicis longus tendon is a major complication after volar locking plate fixation of distal radius fracture. This study used ultrasonography to assess the flexor pollicis longus tendon and intermediate tissue. The study assessed 27 patients (28 wrists) who underwent removal of the volar locking plate. Before plate removal, radiography and ultrasonography were performed to assess the relation between the flexor pollicis longus tendon and the volar locking plate. Intraoperatively, the authors evaluated the intermediate tissues between the flexor pollicis longus tendon and the distal volar margin of the plate. Preoperative and intraoperative findings were compared. Intraoperative findings were strongly related to the distance between the flexor pollicis longus tendon and the volar locking plate on ultrasonography. The sensitivity of ultrasonography in detecting thin, membrane-like intermediate tissue through which the plate was visible was 95%, and the specificity was 89% if the distance between the flexor pollicis longus tendon and the plate was less than 0.7 mm. Compression of the flexor pollicis longus tendon was seen in 11 cases (39.3%), and this finding suggested the presence of thin, membrane-like intermediate tissue. The study results showed that ultrasonography could be used to identify the type of intermediate tissue between the flexor pollicis longus tendon and the volar locking plate. [Orthopedics. 2017; 40(1):e104-e108.].

[1]  J. Stone,et al.  Incidence and clinical outcomes of tendon rupture following distal radius fracture. , 2012, The Journal of hand surgery.

[2]  S. Lifchez,et al.  Flexor Pollicis Longus Tendon Rupture After Volar Plating of a Distal Radius Fracture: Pronator Quadratus Plate Coverage May Not Adequately Protect Tendons , 2011, Eplasty.

[3]  O. Dohi,et al.  Treatment of unstable distal radius fractures with the volar locking plate , 2011, Upsala journal of medical sciences.

[4]  K. Chung,et al.  A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly. , 2011, The Journal of hand surgery.

[5]  P. Blazar,et al.  Volar locking plate implant prominence and flexor tendon rupture. , 2011, The Journal of bone and joint surgery. American volume.

[6]  J. Katarincic,et al.  Fracture of the distal radius: risk factors for complications after locked volar plate fixation. , 2011, The Journal of hand surgery.

[7]  M. Porembski,et al.  Flexor Tendon Problems after Volar Plate Fixation of Distal Radius Fractures , 2009, Hand.

[8]  John D Douthit Volar plating of dorsally comminuted fractures of the distal radius: a 6-year study. , 2005, American journal of orthopedics.

[9]  H. Drobetz,et al.  Osteosynthesis of distal radial fractures with a volar locking screw plate system , 2002, International Orthopaedics.

[10]  J. Orbay The treatment of unstable distal radius fractures with volar fixation. , 2000, Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand.

[11]  J. Keating,et al.  Internal fixation of volar-displaced distal radial fractures. , 1994, The Journal of bone and joint surgery. British volume.