Is the reliability of 3D kinematics of young obese participants dependent on the hip joint center localization method used?

The aim of this study was to investigate if the test-retest reliability for three-dimensional (3D) gait kinematics in a young obese population is affected by using either a predictive (Davis) or a functional (SCoRE) hip joint center (HJC) localization approach. A secondary goal was to analyze how consistent both methods perform in estimating the HJC position. A convenience sample of ten participants, two females and eight males with an age-based body mass index (BMI) above the 97th percentile (mean±SD: 34.2±3.9kg/m2) was recruited. Participants underwent two 3D gait analysis sessions separated by a minimum of one day and a maximum of seven days. The standard error of measurement (SEM) and the root mean square error (RMSE) of key kinematic parameters along with the root mean square deviation (RMSD) of the entire waveforms were used to analyze the test-retest reliability. To get an estimate of the consistency of both HJC localization methods, the HJC positions determined by both methods were compared to each other. SEM, RMSE, and RMSD results indicate that the HJC position estimations between both methods are not different and demonstrate moderate to good reliability to estimate joint kinematics. With respect to the localization of the HJC, notable inconsistencies ranging from 0 to 5.4cm were observed. In conclusion, both approaches appear equally reliable. However, the inconsistent HJC estimation points out, that accuracy seems to be a big issue in these methods. Future research should attend to this matter.

[1]  W. Skalli,et al.  Which method of hip joint centre localisation should be used in gait analysis? , 2014, Gait & posture.

[2]  Hans Kainz,et al.  Reliability of functional and predictive methods to estimate the hip joint centre in human motion analysis in healthy adults. , 2017, Gait & posture.

[3]  Lorenzo Chiari,et al.  Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics. , 2005, Gait & posture.

[4]  W. Taylor,et al.  A survey of formal methods for determining the centre of rotation of ball joints. , 2006, Journal of biomechanics.

[5]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[6]  M O Heller,et al.  Repeatability and reproducibility of OSSCA, a functional approach for assessing the kinematics of the lower limb. , 2010, Gait & posture.

[7]  David G Lloyd,et al.  Repeatability of gait data using a functional hip joint centre and a mean helical knee axis. , 2003, Journal of biomechanics.

[8]  Aurelio Cappozzo,et al.  An optimized protocol for hip joint centre determination using the functional method. , 2006, Journal of biomechanics.

[9]  K Bo Foreman,et al.  In-vivo quantification of dynamic hip joint center errors and soft tissue artifact. , 2016, Gait & posture.

[10]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .

[11]  Reed Ferber,et al.  Can the reliability of three-dimensional running kinematics be improved using functional joint methodology? , 2010, Gait & posture.

[12]  Dara Meldrum,et al.  Test-retest reliability of three dimensional gait analysis: including a novel approach to visualising agreement of gait cycle waveforms with Bland and Altman plots. , 2014, Gait & posture.

[13]  S Toksvig-Larsen,et al.  Validation of a functional method for the estimation of hip joint centre location. , 1999, Journal of biomechanics.

[14]  A Cappozzo,et al.  Soft tissue displacement over pelvic anatomical landmarks during 3-D hip movements. , 2017, Journal of biomechanics.

[15]  Hans Kainz,et al.  Reliability of four models for clinical gait analysis. , 2017, Gait & posture.

[16]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[17]  T. Theologis,et al.  Prediction of the hip joint centre in adults, children, and patients with cerebral palsy based on magnetic resonance imaging. , 2007, Journal of biomechanics.

[18]  Scott L Delp,et al.  Evaluation of a new algorithm to determine the hip joint center. , 2006, Journal of biomechanics.

[19]  S. Holm A Simple Sequentially Rejective Multiple Test Procedure , 1979 .

[20]  David A. Winter,et al.  Biomechanics and Motor Control of Human Movement , 1990 .

[21]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 1: theoretical background. , 2005, Gait & posture.

[22]  M. Dijkers,et al.  Hip joint center location from palpable bony landmarks--a cadaver study. , 1995, Journal of biomechanics.

[23]  William R Taylor,et al.  The SCoRE residual: a quality index to assess the accuracy of joint estimations. , 2011, Journal of biomechanics.

[24]  A. Cappozzo,et al.  Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles , 1999, Medical & Biological Engineering & Computing.

[25]  M. Morris,et al.  The reliability of three-dimensional kinematic gait measurements: a systematic review. , 2009, Gait & posture.

[26]  Arnold Baca,et al.  Within-assessor reliability and minimal detectable change of gait kinematics in a young obese demographic. , 2017, Gait & posture.

[27]  A Cappello,et al.  Effects of hip joint centre mislocation on gait analysis results. , 2000, Journal of biomechanics.

[28]  Maedeh Borhani,et al.  An alternative technical marker set for the pelvis is more repeatable than the standard pelvic marker set , 2013, Gait & posture.

[29]  Hans Kainz,et al.  Effects of hip joint centre mislocation on gait kinematics of children with cerebral palsy calculated using patient-specific direct and inverse kinematic models. , 2017, Gait & posture.

[30]  J. Müller,et al.  Perzentile für den Body-mass-Index für das Kindes- und Jugendalter unter Heranziehung verschiedener deutscher Stichproben , 2001, Monatsschrift Kinderheilkunde.

[31]  David G. Lloyd,et al.  Estimation of the hip joint centre in human motion analysis: a systematic review. , 2015, Clinical biomechanics.

[32]  Zachary F Lerner,et al.  Effects of an obesity-specific marker set on estimated muscle and joint forces in walking. , 2014, Medicine and science in sports and exercise.

[33]  Andrew E. Anderson,et al.  Accuracy of Functional and Predictive Methods to Calculate the Hip Joint Center in Young Non-pathologic Asymptomatic Adults with Dual Fluoroscopy as a Reference Standard , 2015, Annals of Biomedical Engineering.

[34]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[35]  D R Pedersen,et al.  A comparison of the accuracy of several hip center location prediction methods. , 1990, Journal of biomechanics.