Pressure signature of forearm as predictor of grip force.

We studied the relationship between grip force and external forearm pressure in nondisabled subjects using force myography (FMG). FMG uses a sensorized cuff surrounding the forearm to register the distributed mechanical force, detecting pressure on the sensors generated by the volumetric changes of the underlying musculo-tendinous complex. Each of nine nondisabled subjects donned the FMG cuff and applied grip forces to a cylindrical dynamometer; grip forces ranged from 0% to 100% of the subjects' maximum voluntary contraction. The cuff was positioned with seven force sensors located on both the anterior and posterior surfaces of the proximal forearm, but no attempt was made to match sensor placement with particular muscles or sites. Grip prediction was simply encoded as the rectified sum of the FMG sensor outputs. During grip and release cycles, the FMG waveforms of each subject correlated closely with his or her force waveforms (r > 0.89). FMG also correlated highly with the timing of grip onset and release (intraclass correlation coefficient (ICC(A,2)) = 0.99) and time to peak (ICC(A,2) = 0.91), with negligible lag. These results demonstrate that when applied to the forearm, FMG represents a grip force signature that may be useful for near-real-time proportional control of upper-limb prosthetic devices.

[1]  H. Devries MUSCLES ALIVE-THEIR FUNCTIONS REVEALED BY ELECTROMYOGRAPHY , 1976 .

[2]  H. H. Sears,et al.  PROPORTIONAL MYOELECTRIC HAND CONTROL: AN EVALUATION , 1991, American journal of physical medicine & rehabilitation.

[3]  J Malchaire,et al.  Evaluation of handgrip force from EMG measurements. , 1995, Applied ergonomics.

[4]  K. McGraw,et al.  "Forming inferences about some intraclass correlations coefficients": Correction. , 1996 .

[5]  Ian D. Walker,et al.  Myoelectric teleoperation of a complex robotic hand , 1996, IEEE Trans. Robotics Autom..

[6]  W Craelius,et al.  A biomimetic controller for a multifinger prosthesis. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[7]  R Merletti,et al.  Repeatability of surface EMG variables during voluntary isometric contractions of the biceps brachii muscle. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[8]  J H Blok,et al.  Surface EMG models: properties and applications. , 2000, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[9]  J.A. Flint,et al.  Biomimetic finger control by filtering of distributed forelimb pressures , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[10]  William Craelius,et al.  The bionic man: restoring mobility. , 2002, Science.

[11]  T. Kuiken,et al.  The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk , 2003, Prosthetics and orthotics international.

[12]  Rong-Ju Cherng,et al.  Electromyographic analysis of locomotion for healthy and hemiparetic subjects--study of performance variability and rail effect on treadmill. , 2003, Gait & posture.

[13]  Mohammad Hassan Moradi,et al.  Evaluation of the forearm EMG signal features for the control of a prosthetic hand. , 2003, Physiological measurement.

[14]  Kevin B. Englehart,et al.  A robust, real-time control scheme for multifunction myoelectric control , 2003, IEEE Transactions on Biomedical Engineering.

[15]  D. Gabriel,et al.  Reliability of the biceps brachii M-wave , 2005, Journal of NeuroEngineering and Rehabilitation.

[16]  Daniel P. Ferris,et al.  Proportional myoelectric control of a virtual object to investigate human efferent control , 2004, Experimental Brain Research.

[17]  Roberto Merletti,et al.  The extraction of neural strategies from the surface EMG. , 2004, Journal of applied physiology.

[18]  Alcimar Soares,et al.  The Development of a Virtual Myoelectric Prosthesis Controlled by an EMG Pattern Recognition System Based on Neural Networks , 2004, Journal of Intelligent Information Systems.

[19]  Jin-Shin Lai,et al.  The comparison of electromyographic pattern classifications with active and passive electrodes. , 2004, Medical engineering & physics.

[20]  A. Eliasson,et al.  Assessment of capacity for myoelectric control: a new Rasch-built measure of prosthetic hand control. , 2005, Journal of rehabilitation medicine.

[21]  J. Mogk,et al.  The development and validation of equations to predict grip force in the workplace: contributions of muscle activity and posture , 2005, Ergonomics.

[22]  Jaap H van Dieën,et al.  Prediction of handgrip forces using surface EMG of forearm muscles. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[23]  Grigore C. Burdea,et al.  Manipulation Practice for Upper-Limb Amputees Using Virtual Reality , 2005, Presence: Teleoperators & Virtual Environments.

[24]  Sam L. Phillips,et al.  Residual kinetic imaging: a versatile interface for prosthetic control , 2005, Robotica.

[25]  Paul Guinnessy Paul Guinnessy DARPA joins industry, academia to build better prosthetic arms , 2006 .

[26]  Peter J. Keir,et al.  Prediction of forearm muscle activity during gripping , 2006, Ergonomics.

[27]  F. Korkusuz,et al.  Archery performance level and repeatability of event-related EMG. , 2006, Human movement science.

[28]  Roy Want,et al.  Is this the bionic man? , 2006, Nature.

[29]  Silvestro Micera,et al.  Hybrid Bionic Systems for the Replacement of Hand Function , 2006, Proceedings of the IEEE.

[30]  Silvestro Micera,et al.  Design of a cybernetic hand for perception and action , 2006, Biological Cybernetics.

[31]  R.F. Weir,et al.  The Optimal Controller Delay for Myoelectric Prostheses , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[32]  J C K Lai,et al.  Prosthetic devices: Challenges and implications of robotic implants and biological interfaces , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[33]  Roy Want,et al.  The Bionic Man , 2008, IEEE Pervasive Comput..