Present status of room temperature semiconductor detectors

Abstract A review on the present status of room temperature semiconductor nuclear radiation detectors including GaAs, CdTe, HgI2 and diamond detectors with their application is described.

[1]  A. V. Bachurin,et al.  Research of Beta/Gamma Ratio for Diamond Nuclear Radiation Detectors , 1977, IEEE Transactions on Nuclear Science.

[2]  J. Iwanczyk,et al.  Advantages and limitations of n-type low resistivity cadmium telluride nuclear radiation detectors , 1978 .

[3]  G. Entine,et al.  A CdTe Ambulatory Ventricular Function Monitor , 1980, IEEE Transactions on Nuclear Science.

[4]  P. Siffert,et al.  Preparation and Characteristics of Natural Diamond Nuclear Radiation Detectors , 1975, IEEE Transactions on Nuclear Science.

[5]  G. L. Miller A Brief Review of Recent Advances in Compound Semiconductors for Radiation Detectors , 1972 .

[6]  L. Vasanelli,et al.  GaSe as nuclear particle detector , 1974 .

[7]  P. F. Manfredi,et al.  Transport Properties of Natural Diamond Used as Nuclear Particle Detector for a Wide Temperatue Range , 1979, IEEE Transactions on Nuclear Science.

[8]  J. Iwanczyk,et al.  A Study of Low-Noise Preamplifier Systems for Use with Room Temperature Mercuric Iodide (Hgi2) X-Ray Detectors , 1981, IEEE Transactions on Nuclear Science.

[9]  P. E. Gibbons,et al.  High Purity N-Type Gallium Arsenide for Nuclear Particle Detection , 1972 .

[10]  L. T. Jones,et al.  Resolution improvement in CdTe gamma detectors using pulse-shape discrimination , 1975 .

[11]  M. Schieber,et al.  Cadmium telluride and mercuric iodide gamma radiation detectors , 1979 .

[12]  T. Sugita,et al.  Performance of GaAs Surface-Barrier Detectors Made from High-Purity Gallium Arsenide , 1972 .

[13]  M. Schieber,et al.  Reduction of Polarization in Mercuric Iodide Nuclear Radiation Detectors , 1980, IEEE Transactions on Nuclear Science.

[14]  G. Huth,et al.  Toward the Energy Resolution Limit of Mercuric Iodide in Room Temperature Low Energy X-Ray Spectrometry , 1978, IEEE Transactions on Nuclear Science.

[15]  Tsunemasa Taguchi,et al.  Gamma and electron radiation effects in CdTe , 1978 .

[16]  L. T. Jones The use of cadmium telluride γ spectrometers in monitoring activity deposited in nuclear power stations , 1977 .

[17]  I. Beinglass,et al.  State-of-the-art of crystal growth and nuclear spectroscopic evaluation of mercuric iodide radiation detectors , 1978 .

[18]  Jick H. Yee,et al.  What Can Be Expected from High-Z Semiconductor Detectors? , 1976, IEEE Transactions on Nuclear Science.

[19]  J. Joly,et al.  Solution growth of sparingly soluble single crystals from soluble complexes III. Growth of α-HgI2 single crystals from dimethylsulfoxide complexes , 1980 .

[20]  L. van den Berg,et al.  Recent Improvements in HgI2 Detectors , 1978, IEEE Transactions on Nuclear Science.

[21]  P. Glasow,et al.  Aspects of Semiconductor Current Mode Detectors for X-Ray Computed Tomography , 1981, IEEE Transactions on Nuclear Science.

[22]  O. Matveev,et al.  X-ray detectors based on cadmium telluride , 1977 .

[23]  R. J. Fox,et al.  CdTe photovoltaic gamma-ray dosimeter , 1978 .

[24]  M. A. Wolf,et al.  Use of a Cadmium Telluride Detector in a New Tiny Personal Radiation Chirper , 1979, IEEE Transactions on Nuclear Science.

[25]  R. D. Ryan,et al.  Evaluation of epitaxial n-GaAs for nuclear radiation detection , 1971 .

[26]  E. A. Konorova,et al.  Usage of Diamond Detectors as Immersed Alpha-Counters , 1977, IEEE Transactions on Nuclear Science.

[27]  R. D. Ryan,et al.  HIGH-RESOLUTION NUCLEAR RADIATION DETECTORS FROM EPITAXIAL n-GaAs. , 1970 .

[28]  C. Canali,et al.  Electrical properties and performances of natural diamond nuclear radiation detectors , 1979 .

[29]  J. Yee,et al.  ALSB as a High-Energy Photon Detector , 1977, IEEE Transactions on Nuclear Science.

[30]  E. A. Konorova,et al.  Neutron Spectrometry by Diamond Detector for Nuclear Radiation , 1975, IEEE Transactions on Nuclear Science.

[31]  M. Iio,et al.  GaAs Biomedical Probes and Their Applications in Nuclear Medicine , 1973 .

[32]  W. R. Willig Mercury iodide as a gamma spectrometer , 1971 .

[33]  M. Schieber,et al.  Vapor growth of HgI2 by periodic source or crystal temperature oscillation , 1976 .

[34]  E. A. Konorova,et al.  Diamond dosimeter for x-ray and δ-radiation , 1977, IEEE Transactions on Nuclear Science.

[35]  L. Vasanelli,et al.  PbI2 as Nuclear Particle Detector , 1977, IEEE Transactions on Nuclear Science.

[36]  W. Gramann,et al.  Room-temperature GaAs gamma-detectors☆ , 1972 .

[37]  P. Siffert Current possibilities and limitations of cadmium telluride detectors , 1978 .

[38]  A. Holtzer,et al.  Performance Comparison of Standard CdTe and Hgl2 Detectors , 1980, IEEE Transactions on Nuclear Science.

[39]  G. Entine,et al.  Crystal growth of CdTe for γ-ray detectors , 1978 .