Electrogastrogram extraction using independent component analysis with references

Electrogastrogram (EGG) is a noninvasive measurement of gastric myoelectrical activity cutaneously, which is usually covered by strong artifacts. In this paper, the independent component analysis (ICA) with references was applied to separate the gastric signal from noises. The nonlinear uncorrelatedness between the desired component and references was introduced as a constraint. The results show that the proposed method can extract the desired component corresponding to gastric slow waves directly, avoiding the ordering indeterminacy in ICA. Furthermore, the perturbations in EGG can be suppressed effectively. In summary, it can be a useful method for EGG analysis in research and clinical practice.

[1]  Hualou Liang,et al.  Speech Segregation Using Constrained ICA , 2004, ISNN.

[2]  Z. S. Wang,et al.  Blind separation of multichannel electrogastrograms using independent component analysis based on a neural network , 2006, Medical & Biological Engineering & Computing.

[3]  Pierre Comon Independent component analysis - a new concept? signal processing , 1994 .

[4]  Wei Lu,et al.  Eliminating indeterminacy in ICA , 2003, Neurocomputing.

[5]  C. W. Hesse,et al.  The FastICA algorithm with spatial constraints , 2005, IEEE Signal Processing Letters.

[6]  Terrence J. Sejnowski,et al.  An Information-Maximization Approach to Blind Separation and Blind Deconvolution , 1995, Neural Computation.

[7]  Pierre Comon,et al.  Independent component analysis, A new concept? , 1994, Signal Process..

[8]  Wei Lu,et al.  Constrained Independent Component Analysis , 2000, NIPS.

[9]  Aapo Hyv Fast and Robust Fixed-Point Algorithms for Independent Component Analysis , 1999 .

[10]  D. Chakrabarti,et al.  A fast fixed - point algorithm for independent component analysis , 1997 .

[11]  Aapo Hyvärinen,et al.  Fast and robust fixed-point algorithms for independent component analysis , 1999, IEEE Trans. Neural Networks.

[12]  Y. Datian,et al.  Cutaneous Electrical Stimulation of Mid-frequency on Acupiont Affects the Electrogastrogram , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[13]  J. Chen,et al.  Electrogastrography: measuremnt, analysis and prospective applications , 1991, Medical and Biological Engineering and Computing.

[14]  Wei Lu,et al.  Approach and applications of constrained ICA , 2005, IEEE Transactions on Neural Networks.

[15]  H. Liang,et al.  Artifact reduction in electrogastrogram based on empirical mode decomposition method , 2006, Medical and Biological Engineering and Computing.

[16]  Erkki Oja,et al.  Independent Component Analysis , 2001 .

[17]  Ju Liu,et al.  Blind source separation using clustering-based multivariate density estimation algorithm , 2000, IEEE Trans. Signal Process..

[18]  Andrei Irimia,et al.  Artifact reduction in magnetogastrography using fast independent component analysis , 2005, Physiological measurement.

[19]  Richard W. McCallum,et al.  Electrogastrography: Principles and Applications , 1994 .

[20]  Nathalie Delfosse,et al.  Adaptive blind separation of independent sources: A deflation approach , 1995, Signal Process..

[21]  H Liang,et al.  Adaptive independent component analysis of multichannel electrogastrograms. , 2001, Medical engineering & physics.

[22]  H. Liang,et al.  Extraction of gastric slow waves from electrogastrograms: Combining independent component analysis and adaptive signal enhancement , 2005, Medical and Biological Engineering and Computing.

[23]  Ivica Kostanic,et al.  Principles of Neurocomputing for Science and Engineering , 2000 .

[24]  Christopher J. James,et al.  Temporally constrained ICA: an application to artifact rejection in electromagnetic brain signal analysis , 2003, IEEE Transactions on Biomedical Engineering.

[25]  Jie Liang,et al.  Detection and deletion of motion artifacts in electrogastrogram using feature analysis and neural networks , 1997, Annals of Biomedical Engineering.

[26]  J. Vandewalle,et al.  Adaptive method for cancellation of respiratory artefact in electrogastric measurements , 2006, Medical and Biological Engineering and Computing.

[27]  J D Chen,et al.  Clinical applications of electrogastrography. , 1993, The American journal of gastroenterology.