The objective of this study was to evaluate the quality of waste water from a concrete plant that was treated with chemical coagulants combined with Moringa oleifera. In the treatment system employed at the plant, waste-water samples were collected at three different points at the beginning and end of each production week throughout the 1 month production life cycle. The monitored parameters included turbidity, pH, alkalinity and hardness. Samples were collected from an intermediate chamber of the treatment system and treated with coagulants in the laboratory. The results indicated that the quality of the waste water exceeded the established limits for the supply of non-potable water, especially for turbidity. The introduction of the coagulation process significantly improved the quality of the waste water or recycled water (significance of 5%) and 99·94% of the turbidity was removed, which enabled the reuse of water for washing vehicles, producing concrete and flushing toilets.

[1]  B. Chatveera,et al.  Use of ready-mixed concrete plant sludge water in concrete containing an additive or admixture. , 2009, Journal of environmental management.

[2]  I. Azni,et al.  Effects of storage conditions of Moringa oleifera seeds on its performance in coagulation. , 2006, Bioresource technology.

[3]  Tetsuji Okuda,et al.  Improvement of extraction method of coagulation active components from Moringa oleifera seed , 1999 .

[4]  S. O. Ekolu,et al.  Evaluation of recycled water recovered from a ready-mix concrete plant for reuse in concrete , 2010 .

[5]  Leonardo S Andrade,et al.  Chemical coagulants and Moringa oleifera seed extract for treating concrete wastewater , 2016 .

[6]  S. Tsimas,et al.  Reuse of waste water from ready‐mixed concrete plants , 2011 .

[7]  Marina Sangoi de Oliveira Ilha,et al.  Concrete plant wastewater treatment process by coagulation combining aluminum sulfate and Moringa oleifera powder , 2014 .

[8]  Burachat Chatveera,et al.  Effect of sludge water from ready-mixed concrete plant on properties and durability of concrete , 2006 .

[9]  Sidney Seckler Ferreira Filho,et al.  Planejamento e aspectos ambientais envolvidos na disposição final de lodos das estações de tratamento de água da Região Metropolitana de São Paulo , 2007 .

[10]  Maurício Hilgemann,et al.  Avaliação de diferentes coagulantes para a remoção de fósforo em efluente de indústria de laticínios , 2014 .

[11]  Paul S Phillips,et al.  Waste management issues for the UK ready-mixed concrete industry , 2001 .