Design and development of portable potentiostat for advanced research in electrochemical biosensing

Embedded system based, portable potentiostat for Linear Sweep Voltammetry(LSV) is successfully developed. The uniqueness of the system is that it is developed by using off the shelf components for high performance, high resolution and low cost three electrode electrochemical biosensor. It is interfaced with PC by USB. Most important parameters that need to set in electrochemical analysis are scan rate, start potential, end potential and step size of linear sweep voltage. In this system, external 16-bit DAC and 24-bit ADC are interfaced which gives the LSV resolution of 763nV and can capture minimum sensor current of 125nA. This kind of signal resolution is needed for detection of low analyte concentration. Most importantly the system does not need any external memory to store the captured sensor data. An employment of cool term software aids the real-time data capture from biosensor and save it in. txt file format for further parameter estimation.

[1]  Tae Jin Kang,et al.  Polyaniline-Nylon 6 Composite Fabric for Ammonia Gas Sensor , 2004 .

[2]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[3]  Nikolaos Vassiliadis,et al.  A compact hybrid-multiplexed potentiostat for real-time electrochemical biosensing applications. , 2013, Biosensors & bioelectronics.

[4]  Orawon Chailapakul,et al.  An electrochemical sensor based on graphene/polyaniline/polystyrene nanoporous fibers modified electrode for simultaneous determination of lead and cadmium , 2015 .

[5]  B. Thorat,et al.  Sensibility of polyaniline nanofibers to biomarker of benzene recognized as a carcinogen , 2016 .

[6]  A. Turner,et al.  Application of electrical impedance spectroscopy and amperometry in polyaniline modified ammonia gas sensor , 2013 .

[7]  Antje J. Baeumner,et al.  An embedded system for portable electrochemical detection , 2007 .

[8]  B. Nysten,et al.  Optimization of the structural parameters of new potentiometric pH and urea sensors based on polyaniline and a polysaccharide coupling layer , 2012 .

[9]  Jitae Kim,et al.  Studies on tin oxide-intercalated polyaniline nanocomposite for ammonia gas sensing applications , 2009 .

[10]  Liu Deng,et al.  Construction of highly ordered polyaniline nanowires and their applications in DNA sensing. , 2014, Biosensors & bioelectronics.

[11]  O. Chailapakul,et al.  Novel paper-based cholesterol biosensor using graphene/polyvinylpyrrolidone/polyaniline nanocomposite. , 2014, Biosensors & bioelectronics.

[12]  M. Bertino,et al.  Amplified Response and Enhanced Selectivity of Metal-PANI Fiber Composite Based Vapor Sensors , 2012 .

[13]  Gabriele Meloni,et al.  Building a Microcontroller Based Potentiostat: A Inexpensive and Versatile Platform for Teaching Electrochemistry and Instrumentation , 2016 .

[14]  A. Ramanavičius,et al.  Enzymatically synthesized polyaniline layer for extension of linear detection region of amperometric glucose biosensor. , 2010, Biosensors & bioelectronics.