Catheter visualization with resonant markers at MR imaging-guided deployment of endovascular stents in swine.

PURPOSE To evaluate resonant circuits as markers for magnetic resonance (MR) imaging-guided placement of nitinol stents. MATERIALS AND METHODS The study was approved by the institutional animal research committee and complied with National Institutes of Health guidelines for care and use of laboratory animals. Resonant circuits similar to catheter markers used at conventional angiography were placed proximally and distally to a nitinol stent in a stent delivery system. Resonant circuits were tested in vitro and in vivo for signal intensity levels that would enable visualization during MR imaging-guided stent deployment. Experiments were conducted by using real-time imaging with a 1.5-T unit. Stents (n = 9) were deployed in the vena cava (n = 2), abdominal aorta (n = 2), isthmus of the aorta (n = 2), and carotid (n = 2) and iliac (n = 1) arteries in five pigs. After intervention, the site of the stent was investigated with balanced fast field-echo MR imaging and contrast material-enhanced MR angiography. Blood flow velocities were measured in the stent lumen and next to the stent with velocity-encoded cine MR imaging. Level of agreement was determined with Bland-Altman analysis. RESULTS During all interventions, resonant circuits provided highly visible MR signal that allowed fast and reliable visualization of the stent delivery system. Borders of loaded stents were clearly marked, which allowed precise stent placement in all experiments. Balanced fast field-echo MR imaging and contrast-enhanced MR angiography provided information about immediate postintervention position. Positions depicted on MR images were found accurate at postmortem examination. Results of Bland-Altman analysis showed good agreement between blood flow velocities measured in and next to the stent lumen, with a mean difference of -9 cm/sec +/- 5 (standard deviation). CONCLUSION Resonant circuits are well suited for use at deployment of endovascular stents.

[1]  J. Schenck The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. , 1996, Medical physics.

[2]  W. Nitz,et al.  MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study. , 2001, Radiology.

[3]  Titus Kuehne,et al.  Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. , 2003, Radiology.

[4]  C J Bakker,et al.  Passive tracking of catheters and guidewires by contrast‐enhanced MR fluoroscopy , 2001, Magnetic resonance in medicine.

[5]  R Frayne,et al.  A rapid 2D time‐resolved variable‐rate k‐space sampling MR technique for passive catheter tracking during endovascular procedures , 1998, Magnetic resonance in medicine.

[6]  A. Bücker,et al.  Ein Verfahren zur sicheren Visualisierung und Lokalisierung von Kathetern für MR-geführte intravaskuläre Prozeduren , 2003 .

[7]  M. Ladd,et al.  Reduction of resonant RF heating in intravascular catheters using coaxial chokes , 2000, Magnetic Resonance in Medicine.

[8]  Rebecca Fahrig,et al.  Pair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations , 2003, Journal of magnetic resonance imaging : JMRI.

[9]  Keyvan Farahani,et al.  Safety of MRI‐guided endovascular guidewire applications , 2000 .

[10]  C. Higgins,et al.  Sequential Magnetic Resonance Monitoring of Pulmonary Flow With Endovascular Stents Placed Across the Pulmonary Valve in Growing Swine , 2001, Circulation.

[11]  Warren J Manning,et al.  Magnetic Resonance–Guided Coronary Artery Stent Placement in a Swine Model , 2002, Circulation.

[12]  D L Rubin,et al.  Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging. , 1990, Investigative radiology.

[13]  C L Dumoulin,et al.  Real-time biplanar needle tracking for interventional MR imaging procedures. , 1995, Radiology.

[14]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[15]  C J Bakker,et al.  Heating Around Intravascular Guidewires by Resonating RF Waves , 2000, Journal of magnetic resonance imaging : JMRI.