In-line image projection accelerates task performance in laparoscopic appendectomy.

BACKGROUND In laparoscopy, the monitor usually is placed at or above eye level across from the operating surgeon. Position of the endoscopic image at hand level has been shown in a laboratory model to facilitate task performance. The authors tested the hypothesis that in-line image projection reduced operating time for a standardized procedure. METHODS Children undergoing laparoscopic appendectomy were assigned randomly according to video image position: (1) at the top of the laparoscopy tower in front of the surgeon ("overhead") or (2) on a screen placed on the patient's abdomen ("in-line"). Operating time was recorded for each operation, and patients were stratified according to severity of appendicitis and training level of the operating surgeon. Statistical analysis was performed using Student's t, chi2 tests, and analysis of variance with post-hoc Fisher test (P <.05. significant). RESULTS One hundred eight children, aged 2 to 17 years, underwent a laparoscopic appendectomy during a 26-month period. Fifty-four were assigned to the in-line projection screen and 54 to the overhead monitor. Operating time was significantly shorter (P =.013) when in-line projection was used (46.8 +/- 10.2 v. 52.2 +/- 15.1 minutes with overhead monitor). By analysis of variance (ANOVA) the only factors that significantly affected operating time were use of in-line projection (P =.030), severity of appendicitis (P =.002), and training level of the operating surgeon (P =.047). CONCLUSIONS Placing the endoscopic image in the same field as the surgeon's hands decreases operating time by 10%, even for procedures that, like appendectomy, do not require complex suturing skills. This decrease in operating time occurs independently of the surgeon's level of proficiency or the degree of difficulty of the operation.

[1]  K. Georgeson,et al.  The learning curve associated with laparoscopic antireflux surgery in infants and children. , 1997, Journal of pediatric surgery.

[2]  Fernando Molle,et al.  Identification of the preferential gaze position through evaluation of visual fatigue in a selected group of VDU operators , 2005, Documenta Ophthalmologica.

[3]  K. Georgeson Laparoscopic Fundoplication and Gastrostomy , 1998, Seminars in laparoscopic surgery.

[4]  F. Luks,et al.  Cost-effectiveness of laparoscopy in children. , 1999, Archives of pediatrics & adolescent medicine.

[5]  M. Medina Image Rotation and Reversal - Major Obstacles In Learning Intracorporeal Suturing and Knot-Tying , 1997, JSLS : Journal of the Society of Laparoendoscopic Surgeons.

[6]  B. Coventry,et al.  Laparoscopic versus open splenectomy for immune thrombocytopenic purpura. , 1997, Surgery.

[7]  R. Lehr,et al.  Sixteen S-squared over D-squared: a relation for crude sample size estimates. , 1992, Statistics in medicine.

[8]  A. Cuschieri,et al.  Task performance in endoscopic surgery is influenced by location of the image display. , 1998, Annals of surgery.

[9]  A G Gallagher,et al.  Randomly alternating image presentation during laparoscopic training leads to faster automation to the "fulcrum effect". , 2000, Endoscopy.

[10]  C G Cao,et al.  Gaze patterns in laparoscopic surgery. , 1999, Studies in health technology and informatics.

[11]  J. Wenner,et al.  A financial analysis of laparoscopic and open cholecystectomy , 1995, Surgical Endoscopy.

[12]  Luke S. Chang,et al.  Assessment of a Three-Dimensional Operating System with Skill Tests in a Pelvic Trainer , 2000, Urologia Internationalis.

[13]  N Mathers,et al.  Empowering research: statistical power in general practice research. , 1997, Family practice.

[14]  A. Cuschieri,et al.  Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomy , 1998, The Lancet.

[15]  K S Fisher,et al.  Laparoscopic Nissen fundoplication: cost, morbidity, and outcome compared with open surgery. , 1996, Surgical laparoscopy & endoscopy.

[16]  D. M. Herron,et al.  The 3-D monitor and head-mounted display , 1999, Surgical Endoscopy.

[17]  C. Moir Diagnostic laparoscopy and laparoscopic equipment. , 1993, Seminars in pediatric surgery.