Comparative study of silicon detectors

We studied three different types of silicon sensors: PIN diodes, circular drift detectors, both made at the Delft University of Technology (DUT), and Hamamatsu S5345 avalanche photodiodes. Measurements have been carried out in the same optimized experimental setup, both at room temperature and at low temperatures. Comparison is made for direct X-ray detection and CsI(Tl) scintillation light readout.

[1]  R. Mcintyre Multiplication noise in uniform avalanche diodes , 1966 .

[2]  Heike Soltau,et al.  Silicon drift detectors for high resolution room temperature X-ray spectroscopy , 1996 .

[3]  Marco Sampietro,et al.  Suboptimal filtering of 1/ƒ-noise in detector charge measurements , 1990 .

[4]  P. Dorenbos,et al.  Non-proportionality in the scintillation response and the energy resolution obtainable with scintill , 1995 .

[5]  K. Shah,et al.  Advances in semiconductor photodetectors for scintillators , 1997 .

[6]  Dieter Renker,et al.  Some studies of avalanche photodiode readout of fast scintillators , 1995 .

[7]  D. Landis,et al.  Semiconductor Detector Spectrometer Electronics , 1974 .

[8]  M. Sampietro,et al.  Spectroscopy charge amplifier for detectors with integrated front-end FET , 1995 .

[9]  Roger Lecomte,et al.  Recent results in scintillation detection with silicon avalanche photodiodes , 1990 .

[10]  Pavel Rehak,et al.  Semiconductor drift chamber: an application of a novel charge transport scheme , 1984 .

[11]  A. Baron,et al.  Time resolved detection of x-rays using large area avalanche photodiodes , 1994 .

[12]  D. W. Aitken,et al.  Fano Factor Fact and Fallacy , 1970 .

[13]  G. Bertuccio,et al.  Room temperature X-ray spectroscopy with a silicon diode detector and an ultra low noise preamplifier , 1994 .

[14]  Eiji Sakai,et al.  Recent Measurements on Scintillator-Photodetector Systems , 1987, IEEE Transactions on Nuclear Science.

[15]  Roger Lecomte,et al.  Status of BGO-avalanche photodiode detectors for spectroscopic and timing measurements , 1989 .

[16]  G. Bertuccio,et al.  Resolution limits of silicon detectors and electronics for soft X-ray spectroscopy at non cryogenic temperatures☆ , 1996 .

[17]  A. Ochi,et al.  Study of a large area avalanche photodiode as a fast photon and a soft X-ray detector , 1996 .

[18]  Joseph Cerny,et al.  Nuclear spectroscopy and reactions , 1974 .

[19]  K. Lynn,et al.  Silicon PIN photodetectors in high resolution nuclear spectroscopy , 1992 .

[20]  Pascal Elleaume,et al.  A high-resolution silicon drift chamber for X-ray spectroscopy , 1994 .

[21]  J. P. Pansart,et al.  AVALANCHE PHOTODIODES FOR PARTICLE DETECTION , 1997 .