Optimal and adaptive compensation of voltage and current harmonics of nonlinear loads under nonstiff voltage conditions
暂无分享,去创建一个
In this paper operation of OFC based active power filters under nonstiff and distorted voltage conditions is investigated. Under these conditions there exist a feedback from the load currents to the load voltages hence this situation makes the OFC based system a closed loop adaptive system which may represent an unstable or poor transient response behavior. By identifying the source equivalent circuit an improved OFC algorithm (IOFC) has been proposed The proposed control algorithm considers the load voltages variation due to the load current variation. Successful performance of the proposed algorithm has been investigated and proved by several MATLAB based simulation studies. A new compensation strategy based on IOFC system which minimizes the load voltage harmonics has been proposed and investigated.
[1] Hirofumi Akagi,et al. A study of active power filters using quad-series voltage-source PWM converters for harmonic compensation , 1990 .
[2] R. Ghazi,et al. IEEE-519-Based Real-Time and Optimal Control of Active Filters under Nonsinusoidal Line Voltages Using Neural Networks , 2002, IEEE Power Engineering Review.
[3] Reza Ghazi,et al. An optimal and flexible control strategy for active filtering and power factor correction under non-sinusoidal line voltages , 2001 .