Geometric changes after tricuspid annuloplasty and predictors of residual tricuspid regurgitation: a real-time three-dimensional echocardiography study.

AIMS We sought to demonstrate geometric changes in the tricuspid valve (TV) apparatus after tricuspid annuloplasty (TAP) and to identify predictors of residual tricuspid regurgitation (TR) in patients with functional TR using real-time three-dimensional echocardiography (RT3DE). METHODS AND RESULTS RT3DE and two-dimensional colour Doppler echocardiography were performed in 59 consecutive patients before and 4.7 ± 2.1 days after TAP. The tenting angles of the three leaflets were significantly increased, whereas tenting volume, annulus diameters, and septal-lateral right ventricular inlet dimension decreased after TAP. By multiple stepwise linear regression analysis, tenting volume (P < 0.001) and antero-posterior annulus diameter (P = 0.043) before TAP were major predictors of residual TR assessed using distal jet area. When TR severity was quantified by vena contracta width, tenting volume (P < 0.001) before TAP was the only independent predictor. Pre-TAP tenting volume ≥1.68 mL (sensitivity of 86%, specificity of 73%), and ≥2.30 mL (sensitivity of 100%, specificity of 84%) were the best cut-off values predicting severe residual TR quantified using distal jet area and vena contracta width, respectively. After TAP, tenting volume and pulmonary artery systolic pressure were major determinants of residual TR. CONCLUSION Tenting angles of all three leaflets increase, whereas annulus diameters decrease, after TAP. Pre-TAP tenting volume and antero-posterior annulus diameter measured using RT3DE are independent predictors of residual TR severity, and measurement of these parameters may help to identify patients at high risk for severe residual TR, for whom TV replacement should possibly be initially considered.

[1]  I. Yada,et al.  Long-term follow-up after Carpentier-Edwards ring annuloplasty for tricuspid regurgitation. , 2000, The Annals of thoracic surgery.

[2]  Robert A Levine,et al.  Geometric Determinants of Functional Tricuspid Regurgitation: Insights From 3-Dimensional Echocardiography , 2006, Circulation.

[3]  Mario J. Garcia,et al.  Value of mitral valve tenting volume determined by real-time three-dimensional echocardiography in patients with functional mitral regurgitation. , 2006, The American journal of cardiology.

[4]  Young‐Bae Park,et al.  Impact of the Maze Operation Combined With Left-Sided Valve Surgery on the Change in Tricuspid Regurgitation Over Time , 2005, Circulation.

[5]  Jayant Nath,et al.  Impact of tricuspid regurgitation on long-term survival. , 2004, Journal of the American College of Cardiology.

[6]  R. Hall,et al.  Reduced exercise capacity in patients with tricuspid regurgitation after successful mitral valve replacement for rheumatic mitral valve disease. , 1991, British heart journal.

[7]  G. Dreyfus,et al.  Tricuspid leaflet augmentation to address severe tethering in functional tricuspid regurgitation. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[8]  Jong-Min Song,et al.  Geometric and hemodynamic determinants of functional tricuspid regurgitation: a real-time three-dimensional echocardiography study. , 2008, International journal of cardiology.

[9]  Susan Armstrong,et al.  Tricuspid Valve Repair With an Annuloplasty Ring Results in Improved Long-Term Outcomes , 2006, Circulation.

[10]  S. Kaul,et al.  Assessment of right ventricular function using two-dimensional echocardiography. , 1984, American heart journal.

[11]  James D. Thomas,et al.  Tricuspid Valve Tethering Predicts Residual Tricuspid Regurgitation After Tricuspid Annuloplasty , 2005, Circulation.

[12]  Yasuo Ogasawara,et al.  Geometric changes of tricuspid valve tenting in tricuspid regurgitation secondary to pulmonary hypertension quantified by novel system with transthoracic real-time 3-dimensional echocardiography. , 2007, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[13]  Takahiro Shiota,et al.  Determinants of Recurrent or Residual Functional Tricuspid Regurgitation After Tricuspid Annuloplasty , 2006, Circulation.

[14]  G. Gatti,et al.  Tricuspid valve repair with the Cosgrove-Edwards annuloplasty system: early clinical and echocardiographic results. , 2001, The Annals of thoracic surgery.

[15]  P. Yock,et al.  Noninvasive estimation of right ventricular systolic pressure by Doppler ultrasound in patients with tricuspid regurgitation. , 1984, Circulation.

[16]  M. Ajuria,et al.  Carpentier's flexible ring versus De Vega's annuloplasty. A prospective randomized study. , 1985, The Journal of thoracic and cardiovascular surgery.

[17]  Robert J Cody,et al.  Prognostic significance of mitral regurgitation and tricuspid regurgitation in patients with left ventricular systolic dysfunction. , 2002, American heart journal.

[18]  R. Levine,et al.  Mechanism of Persistent Ischemic Mitral Regurgitation After Annuloplasty: Importance of Augmented Posterior Mitral Leaflet Tethering , 2005, Circulation.

[19]  René M. Botnar,et al.  Molecular Magnetic Resonance Imaging of Atrial Clots in a Swine Model , 2005, Circulation.

[20]  Jeevanantham Rajeswaran,et al.  Tricuspid valve repair: durability and risk factors for failure. , 2004, The Journal of thoracic and cardiovascular surgery.

[21]  T. Abe,et al.  De Vega's annuloplasty for acquired tricuspid disease: early and late results in 110 patients. , 1989, The Annals of thoracic surgery.

[22]  Y. Ueda,et al.  De Vega annuloplasty and Carpentier-Edwards ring annuloplasty for secondary tricuspid regurgitation. , 2001, The Journal of heart valve disease.

[23]  S. Yun,et al.  Impact of the Maze operation on the progression of mild functional tricuspid regurgitation. , 2008, The Journal of thoracic and cardiovascular surgery.

[24]  R. Levine,et al.  Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. , 2003, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[25]  K. Kuwaki,et al.  Tricuspid valve surgery for functional tricuspid valve regurgitation associated with left-sided valvular disease. , 2001, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[26]  Richard B Devereux,et al.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardio , 2005, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.