Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame.

BACKGROUND AND PURPOSE Evaluation of set-up accuracy and analysis of target reproducibility in the stereotactic body frame (SBF), designed by Blomgren and Lax from Karolinska Hospital, Stockholm. Different types of targets were analyzed for the risk of target deviation. The correlation of target deviation to bony structures was analyzed to evaluate the value of bones as reference structures for isocenter verification. MATERIALS AND METHODS Thirty patients with 32 targets were treated in the SBF for primary or metastatic peripheral lung cancer, liver metastases, abdominal and pelvic tumor recurrences or bone metastases. Set-up accuracy and target mobility were evaluated by CT-simulation and port films. The contours of the target at isocenter level, bony structures and body outline were compared by matching the CT-slices for treatment planning and simulation using the stereotactic coordinates of the SBF as external reference system. The matching procedure was performed by using a 3D treatment planning program. RESULTS Set-up accuracy represented by bony structures revealed standard deviations (SD) of 3.5 mm in longitudinal, 2.2 mm in anterior-posterior and 3.9 mm in lateral directions. Target reproducibility showed a SD of 4.4 mm in longitudinal, 3.4 mm ap and 3.3 mm in lateral direction prior to correction. Correlation of target deviation to bones ranged from 33% (soft tissue targets) to 100% (bones). CONCLUSION A security margin of 5 mm for PTV definition is sufficient, if CT simulation is performed prior to each treatment to correct larger target deviations or set-up errors. Isocenter verification relative to bony structures is only safe for bony targets but not for soft tissue targets.

[1]  M Wannenmacher,et al.  Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer. , 1996, International journal of radiation oncology, biology, physics.

[2]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[3]  J A Antolak,et al.  Prostate target volume variations during a course of radiotherapy. , 1998, International journal of radiation oncology, biology, physics.

[4]  R. Cowan,et al.  Bladder movement during radiation therapy for bladder cancer: implications for treatment planning. , 1997, International journal of radiation oncology, biology, physics.

[5]  T Kozuka,et al.  Lung cancer: intermittent irradiation synchronized with respiratory motion--results of a pilot study. , 1998, Radiology.

[6]  M. Goitein,et al.  Accuracy of radiation field alignment in clinical practice. , 1985, International journal of radiation oncology, biology, physics.

[7]  Impact of cradle immobilization on setup reproducibility during external beam radiation therapy for lung cancer. , 1997, International journal of radiation oncology, biology, physics.

[8]  K. Lam,et al.  Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. , 1998, International journal of radiation oncology, biology, physics.

[9]  G. Tsumatori,et al.  Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients , 1998, Cancer.

[10]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[11]  F Lohr,et al.  Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases. , 2000, International journal of radiation oncology, biology, physics.

[12]  K. Bratengeier,et al.  CT simulation in stereotactic brain radiotherapy--analysis of isocenter reproducibility with mask fixation. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  I. Lax,et al.  Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients. , 1995, Acta oncologica.

[14]  J M Balter,et al.  Potential benefits of eliminating planning target volume expansions for patient breathing in the treatment of liver tumors. , 1997, International journal of radiation oncology, biology, physics.

[15]  E. Touboul,et al.  Kidney mobility during respiration. , 1994, Radiotherapy and Oncology.

[16]  R Calandrino,et al.  Set-up error in supine-positioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  Lohr Frank,et al.  Extracranial stereotactic conformal radiation treatment of tumors in the liver and the lung , 1998 .

[18]  T. Landberg,et al.  What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  R. Edelman,et al.  Diaphragmatic and cardiac motion during suspended breathing: preliminary experience and implications for breath-hold MR imaging. , 1998, Radiology.

[20]  A Dutreix,et al.  Radiotherapy of pelvic malignancies: impact of two types of rigid immobilisation devices on localisation errors. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  D. Low,et al.  A critical evaluation of the planning target volume for 3-D conformal radiotherapy of prostate cancer. , 1998, International journal of radiation oncology, biology, physics.

[22]  I. Lax,et al.  Radiosurgery for Tumors in the Body: Clinical Experience Using a New Method , 1998 .

[23]  M Wannenmacher,et al.  Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  J Bijhold,et al.  Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  I. Lax,et al.  Extracranial Stereotactic Radiosurgery of Localized Targets , 1998 .