Internal Current Return Path for Ground Leakage Current Mitigation in Current Source Inverters

This paper analyzes in detail the effect of a simple solution for ground leakage current mitigation applicable to transformerless three-phase current source inverter (CSI). The circuit modification solution is assessed for both traditional CSI topology and for CSI with an additional seventh switch, in literature named CSI7 (or H7), in particular with the splitting of the dc input inductance. In the present work, the solution is applied to grid-connected converters for string photovoltaic applications: scope of the circuit modification is to provide an internal return path from the wye connected capacitors of the output CL filter. This additional return path is able to significantly reduce the ground leakage current without adversely affecting THD. The performance of the proposed solution is assessed by the numerical simulations in case of a string of photovoltaic (PV) modules and the different behavior of CSI and CSI7 topologies is thoroughly investigated. Furthermore, the definition of $V_{cmZC}$ is assessed by applying it to the common mode equivalent circuits for CSI7 with additional return path and their validation by means of a two-step simulation. The simulation results and experimental validation shows good agreement and confirm that the proposed solution is able to strongly reduce the ground leakage current.

[1]  Samir Kouro,et al.  Modeling and analysis of common-mode voltages generated in medium voltage PWM-CSI drives , 2003 .

[2]  Marco Liserre,et al.  Assessment of Efficiency and Reliability of Wide Band-Gap Based H8 Inverter in Electric Vehicle Applications , 2019, Energies.

[3]  B. Sahan,et al.  Comparative Evaluation of Three-Phase Current Source Inverters for Grid Interfacing of Distributed and Renewable Energy Systems , 2011, IEEE Transactions on Power Electronics.

[4]  Peter Zacharias,et al.  A Single-Stage PV Module Integrated Converter Based on a Low-Power Current-Source Inverter , 2008, IEEE Transactions on Industrial Electronics.

[5]  D. Boroyevich,et al.  Leakage Current Reduction in a Single-Phase Bidirectional AC–DC Full-Bridge Inverter , 2012, IEEE Transactions on Power Electronics.

[6]  E. Lorenzani,et al.  Ground Leakage Current Mitigation for Three-Phase Current Source Inverters , 2018, 2018 IEEE Energy Conversion Congress and Exposition (ECCE).

[7]  Alessandro Ciocia,et al.  Ground currents in a photovoltaic power plant: Theoretical approach and experimental tests , 2017, 2017 IEEE Manchester PowerTech.

[8]  Jie Zhang,et al.  Single-Stage Three-Phase Current-Source Photovoltaic Grid-Connected Inverter High Voltage Transmission Ratio , 2017, IEEE Transactions on Power Electronics.

[9]  Giampaolo Buticchi,et al.  Digital Control of Actual Grid-Connected Converters for Ground Leakage Current Reduction in PV Transformerless Systems , 2012, IEEE Transactions on Industrial Informatics.

[10]  F. Blaabjerg,et al.  Review and Comparison of Step-Up Transformerless Topologies for Photovoltaic AC-Module Application , 2013, IEEE Transactions on Power Electronics.

[11]  Emilio Lorenzani,et al.  CSI7: A Modified Three-Phase Current-Source Inverter for Modular Photovoltaic Applications , 2017, IEEE Transactions on Industrial Electronics.