Traceable calibration of radiation sources from the visible to the far infrared for space borne applications at PTB

The Physikalisch-Technische Bundesanstalt (PTB) has developed dedicated instrumentations and methods for the traceable calibration of space borne instruments in terms of the three fundamental radiometric units, i.e. spectral radiance (radiation temperature), spectral radiant intensity and spectral photon flux. The traceable calibration under conditions similar to the space environment is achieved by use of two major radiometric calibration facilities of PTB, the Spectral Radiance Comparator Facility (SRCF) and the Reduced Background Calibration Facility (RBCF) which are part of the Primary Temperature Radiator Facility of PTB and cover the wavelength range from the UV to the FIR (THz range). The improved detector instrumentations of the SRCF and RBCF, detailed calibration schemes and results of calibrations for space missions are presented.

[1]  H. Jung Spectral Nonlinearity Characteristics of Low Noise Silicon Detectors and their Application to Accurate Measurements of Radiant Flux Ratios , 1979 .

[2]  R. D. Taubert,et al.  The spectral photon flux of the radiometric calibration spectral source for the NIRSpec instrument of the James Webb Space Telescope , 2009 .

[3]  C. Fröhlich,et al.  Accurate radiometers should measure the output of the Sun , 1999, Nature.

[4]  Holger Venus,et al.  MERTIS: a highly integrated IR imaging spectrometer , 2006, SPIE Optics + Photonics.

[5]  C. Fröhlich,et al.  Solar Irradiance Variability Since 1978 , 2007 .

[6]  Christian Monte,et al.  Radiation Thermometry and Emissivity Measurements Under Vacuum at the PTB , 2009 .

[7]  T. Jankowski,et al.  A Vacuum Infrared Standard Radiation Thermometer at the PTB , 2008 .

[8]  J. Hartmann,et al.  High-temperature measurement techniques for the application in photometry, radiometry and thermometry , 2009 .

[9]  D. R. Taubert,et al.  High-accuracy radiation thermometry at the National Metrology Institute of Germany, the PTB , 2003 .

[10]  Christian Monte,et al.  The reduced background calibration facility for detectors and radiators at the Physikalisch-Technische Bundesanstalt , 2009, Remote Sensing.

[11]  R Friedrich,et al.  New spectral radiance scale from 220 nm to 2500 nm , 2000 .

[12]  H. Rix,et al.  The James Webb Space Telescope , 2006, astro-ph/0606175.

[13]  U. Johannsen,et al.  Accurate determination of the spectral responsivity of silicon trap detectors between 238 nm and 1015 nm using a laser-based cryogenic radiometer , 2000 .