Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography

The multi-wavelength photoplethysmography sensors were introduced to measure depth-dependent blood volume based on that concept that the longer the light wavelength, the deeper the penetration depth near visible spectrum band. In this study, we propose an omnidirectional optical sensor module that can measure photoplethysmogram while using multiple wavelengths, and describe implementation detail. The developed sensor is manufactured by making a hole in a metal plate and mounting an LED therein, and it has four wavelength LEDs of blue (460 nm), green (530 nm), red (660 nm), and IR (940 nm), being arranged concentrically around a photodetector. Irradiation light intensity was measured by photoluminescent test, and photoplethymogram was measured with each wavelength simultaneously at a periphery of the human body such as fingertip, earlobe, toe, forehead, and wrist, in order to evaluate the developed sensor. As a result, the developed sensor module showed a linear increase of irradiating light intensity according to the number of LEDs increases, and pulsatile waveforms were observed at all four wavelengths in all measuring sites.

[1]  Daniela Vecchio,et al.  Low-level laser (light) therapy (LLLT) in skin: stimulating, healing, restoring. , 2013, Seminars in cutaneous medicine and surgery.

[2]  Yuan-Ting Zhang,et al.  Multi-Wavelength Photoplethysmography Enabling Continuous Blood Pressure Measurement With Compact Wearable Electronics , 2019, IEEE Transactions on Biomedical Engineering.

[3]  Janis Spigulis,et al.  Multi-wavelength photoplethysmography for simultaneous recording of skin blood pulsations at different vascular depths , 2007, SPIE BiOS.

[4]  S. Arridge,et al.  Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .

[5]  Janis Spigulis,et al.  Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmography. , 2007, Applied optics.

[6]  Kwang Suk Park,et al.  Effect of sensor configurations on indirect-contact photoplethysmogram measurement system , 2010, 2010 5th Cairo International Biomedical Engineering Conference.

[7]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[8]  Subhasri Chatterjee,et al.  Monte Carlo Analysis of Optical Interactions in Reflectance and Transmittance Finger Photoplethysmography , 2019, Sensors.

[9]  Yuan-Ting Zhang,et al.  Effects of cuff inflation and deflation on pulse transit time measured from ECG and multi-wavelength PPG , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[10]  Xiao-Rong Ding,et al.  Multi-wavelength photoplethysmography method for skin arterial pulse extraction. , 2016, Biomedical optics express.

[11]  Yuan-Ting Zhang,et al.  A preliminary study on multi-wavelength PPG based pulse transit time detection for cuffless blood pressure measurement , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  A. Pries,et al.  Relationship between structural and hemodynamic heterogeneity in microvascular networks. , 1996, The American journal of physiology.

[13]  A. Habtemariam,et al.  Upconverting nanoparticles for the near infrared photoactivation of transition metal complexes: new opportunities and challenges in medicinal inorganic photochemistry. , 2016, Dalton transactions.