Inflow and Fatigue Response of the NWTC Advanced Research Turbine

The Long-term Inflow and Structural Test (LIST) program is collecting long-term inflow and structural response data to characterize the spectrum of loads on wind turbines. In one of the measurement campaigns being conducted under this program, the 42-m diameter, 600-kW NWTC Advanced Research Turbine (ART) was monitored. The turbine is an upwind, two-bladed teetered-hub machine. It has full span pitch control and a synchronous generator. The inflow was monitored with a planar array of five high-resolution sonic anemometers and supporting meteorological instrumentation located 1.5 diameters upwind of the turbine. The structural response of the turbine was measured using strain gauge circuits and an inertial measurement unit (IMU). The former were used to monitor root bending moments and the low-speed shaft torque, while the latter was used to monitor the motion of the tower and the nacelle. Auxiliary gauges measured blade pitch, rotor teeter, nacelle yaw and generator power. A total of 3299 10-minute records were collected for analysis. From this set, 1044 records are used to examine the influence of various inflow parameters on fatigue loads. Long-term fatigue loads and extreme loads are also examined.© 2003 ASME

[1]  Alan Wright,et al.  Long-term simulation of turbulence-induced loads using the SNLWIND-3D, FAST, YawDyn, and ADAMS numerical codes , 1997 .

[2]  S. M. Hock,et al.  Preliminary results from the dynamic response testing of the Westinghouse 600-kW wind turbine , 1987 .

[3]  Herbert J. Sutherland INFLOW AND THE FATIGUE OF THE LIST WIND TURBINE , 2002 .

[4]  David J. Malcolm,et al.  RESULTS FROM THE ADVANCED RESEARCH TURBINE PROJECT , 2000 .

[5]  David Laino,et al.  Evaluating statistical loads extrapolation methods , 2000 .

[6]  N. D. Kelley The identification of inflow fluid dynamics parameters that can be used to scale fatigue loading spectra of wind turbine structural components , 1993 .

[7]  L. E. Van Bibber,et al.  The dynamic response of a Westinghouse 600-kW wind turbine , 1989 .

[8]  Herbert J. Sutherland Analysis of the structural and inflow data from the list turbine , 2002 .

[9]  David J. Malcolm,et al.  An approach to the development of turbine loads in accordance with IEC 1400-1 and ISO 2394 , 1999 .

[10]  A. Fragoulis,et al.  The complex terrain wind environment and its effects on the power output and loading of wind turbines , 1997 .

[11]  Peter Hauge Madsen,et al.  Predicting Ultimate Loads for Wind Turbine Design , 1998 .

[12]  N. D. Kelley,et al.  The evaluation of a turbulent loads characterization system , 1996 .

[13]  Neil Kelley,et al.  The NREL Large-Scale Turbine Inflow and Response Experiment ― Preliminary Results , 2002 .