Detector clothes for MRI: A wearable array receiver based on liquid metal in elastic tubes

In modern magnetic resonance imaging, signal detection is performed by dense arrays of radiofrequency resonators. Tight-fitting arrays boost the sensitivity and speed of imaging. However, current devices are rigid and cage-like at the expense of patient comfort. They also constrain posture, limiting the examination of joints. For better ergonomics and versatility, detectors should be flexible, adapt to individual anatomy, and follow posture. Towards this goal, the present work proposes a novel design based on resonators formed by liquid metal in polymer tubes. Textile integration creates lightweight, elastic devices that are worn like pieces of clothing. A liquid-metal array tailored to the human knee is shown to deliver competitive image quality while self-adapting to individual anatomy and adding the ability to image flexion of the joint. Relative to other options for stretchable conductors, liquid metal in elastic tubes stands out by reconciling excellent electrical and mechanical properties with ease of manufacturing.

[1]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[2]  Klaas Paul Pruessmann,et al.  On the Bending and Stretching of Liquid Metal Receive Coils for Magnetic Resonance Imaging , 2019, IEEE Transactions on Biomedical Engineering.

[3]  Andrew Webb,et al.  Shielded‐coaxial‐cable coils as receive and transceive array elements for 7T human MRI , 2019, Magnetic resonance in medicine.

[4]  X Marchandise,et al.  A new, fully versatile surface coil for MRI. , 1990, Magnetic resonance imaging.

[5]  Andreas Peter,et al.  An MRI Receiver Coil Produced by Inkjet Printing Directly on to a Flexible Substrate , 2010, IEEE Transactions on Medical Imaging.

[6]  D. Blezek,et al.  128‐channel body MRI with a flexible high‐density receiver‐coil array , 2008, Journal of magnetic resonance imaging : JMRI.

[7]  Stephen J Riederer,et al.  Characterization and evaluation of a flexible MRI receive coil array for radiation therapy MR treatment planning using highly decoupled RF circuits , 2018, Physics in medicine and biology.

[8]  Xiaoying Wang,et al.  Knee MRI under varying flexion angles utilizing a flexible flat cable antenna , 2015, NMR in biomedicine.

[9]  Ada S. Y. Poon,et al.  A Millimeter-Wave Digital Link for Wireless MRI , 2017, IEEE Transactions on Medical Imaging.

[10]  Tao Zhang,et al.  Depletion-Mode GaN HEMT Q-Spoil Switches for MRI Coils , 2016, IEEE Transactions on Medical Imaging.

[11]  Joon B. Park Biomaterials:An Introduction , 1992 .

[12]  G. Whitesides,et al.  Eutectic Gallium‐Indium (EGaIn): A Liquid Metal Alloy for the Formation of Stable Structures in Microchannels at Room Temperature , 2008 .

[13]  M. Walsh,et al.  An Introduction , 2002, The Counseling Psychologist.

[14]  Daniel K Sodickson,et al.  A high-impedance detector-array glove for magnetic resonance imaging of the hand , 2018, Nature Biomedical Engineering.

[15]  N. De Zanche,et al.  Stretchable coil arrays: Application to knee imaging under varying flexion angles , 2012, Magnetic resonance in medicine.

[16]  Steen Moeller,et al.  A geometrically adjustable 16‐channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla , 2008, Magnetic resonance in medicine.

[17]  N. De Zanche,et al.  Mechanically adjustable coil array for wrist MRI , 2009, Magnetic resonance in medicine.

[18]  Bei Zhang,et al.  Size‐adaptable “Trellis” structure for tailored MRI coil arrays , 2019, Magnetic resonance in medicine.

[19]  Ewald Moser,et al.  Flexible 23-channel coil array for high-resolution magnetic resonance imaging at 3 Tesla , 2018, PloS one.

[20]  Simone A. Winkler,et al.  An MRI Compatible RF MEMs Controlled Wireless Power Transfer System , 2019, IEEE Transactions on Microwave Theory and Techniques.

[21]  Thomas Burger,et al.  A Fully Integrated Dual-Channel On-Coil CMOS Receiver for Array Coils in 1.5–10.5 T MRI , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[22]  W. Kwok,et al.  A volume adjustable four-coil phased array for high resolution MR imaging of the hip , 1999, Magnetic Resonance Materials in Physics, Biology and Medicine.

[23]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[24]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[25]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[26]  G. Lodygensky,et al.  Size‐adaptable 13‐channel receive array for brain MRI in human neonates at 3 T , 2018, NMR in biomedicine.

[27]  Urs Moser,et al.  An In-Bore Receiver for Magnetic Resonance Imaging , 2020, IEEE Transactions on Medical Imaging.

[28]  J A Malko,et al.  A flexible mercury-filled surface coil for MR imaging. , 1986, AJNR. American journal of neuroradiology.

[29]  Michael Lustig,et al.  Screen-printed flexible MRI receive coils , 2016, Nature Communications.

[30]  M. Dickey Stretchable and Soft Electronics using Liquid Metals , 2017, Advanced materials.

[31]  Joseph V Rispoli,et al.  Conductive Thread-Based Stretchable and Flexible Radiofrequency Coils for Magnetic Resonance Imaging , 2019, IEEE Transactions on Biomedical Engineering.

[32]  Gerhard Tröster,et al.  Adsorbed Eutectic GaIn Structures on a Neoprene Foam for Stretchable MRI Coils , 2017, Advanced materials.