Longitudinal gradient coil optimization in the presence of transient eddy currents

The switching of magnetic field gradient coils in magnetic resonance imaging (MRI) inevitably induces transient eddy currents in conducting system components, such as the cryostat vessel. These secondary currents degrade the spatial and temporal performance of the gradient coils, and compensation methods are commonly employed to correct for these distortions. This theoretical study shows that by incorporating the eddy currents into the coil optimization process, it is possible to modify a gradient coil design so that the fields created by the coil and the eddy currents combine together to generate a spatially homogeneous gradient that follows the input pulse. Shielded and unshielded longitudinal gradient coils are used to exemplify this novel approach. To assist in the evaluation of transient eddy currents induced within a realistic cryostat vessel, a low‐frequency finite‐difference time‐domain (FDTD) method using the total‐field scattered‐field (TFSF) scheme was performed. The simulations demonstrate the effectiveness of the proposed method for optimizing longitudinal gradient fields while taking into account the spatial and temporal behavior of the eddy currents. Magn Reson Med 57:1119–1130, 2007. © 2007 Wiley‐Liss, Inc.

[1]  A. Caprihan,et al.  A programmable pre‐emphasis system , 1998, Magnetic resonance in medicine.

[2]  D. Doddrell,et al.  Correction of eddy-current-induced B0 shifts by receiver reference-phase modulation , 1992 .

[3]  Robert W Brown,et al.  Supershielding: Confinement of magnetic fields , 1999 .

[4]  R. Turner,et al.  Passive screening of switched magnetic field gradients , 1986 .

[5]  Melinda Piket-May,et al.  9 – Computational Electromagnetics: The Finite-Difference Time-Domain Method , 2005 .

[6]  Feng Liu,et al.  An FDTD model for calculation of gradient-induced eddy currents in MRI system , 2004, IEEE Transactions on Applied Superconductivity.

[7]  G. Ries Eddy current transients and forces in cryostat walls of superconducting solenoids , 1988 .

[8]  R. Turner,et al.  Gradient coil design: a review of methods. , 1993, Magnetic resonance imaging.

[9]  P. Mansfield,et al.  Active magnetic screening of coils for static and time-dependent magnetic field generation in NMR imaging , 1986 .

[10]  Z H Cho,et al.  Analysis of eddy currents in nuclear magnetic resonance imaging , 1991, Magnetic resonance in medicine.

[11]  Eddy current effects in MRI superconducting magnets , 1997 .

[12]  Feng Liu,et al.  Analysis of Transient Eddy Currents in MRI Using a Cylindrical FDTD Method , 2006, IEEE Transactions on Applied Superconductivity.

[13]  R. Mittra,et al.  Parallel Finite-Difference Time-Domain Method (Artech House Electromagnetic Analysis) , 2006 .

[14]  Sh.M. Shvartsman,et al.  Ultrashort shielded gradient coil design with 3D geometry , 2005 .

[15]  R. Bowtell,et al.  Gradient coil design using active magnetic screening , 1991, Magnetic resonance in medicine.

[16]  S Crozier,et al.  A design methodology for short, whole-body, shielded gradient coils for MRI. , 1995, Magnetic resonance imaging.