A fouling model for simulating long-term performance of SWRO desalination process

A fouling model for the seawater reverse osmosis (SWRO) process is required to propose an appropriate strategy for membrane maintenance (i.e., membrane cleaning and replacement). In this study, a fouling model that considered the concentration polarization was properly developed to simulate the long-term performance of the SWRO process based on models from the literature. The model was practically applied to one-year operation data obtained from the Fujairah SWRO desalination plant with parameter estimation, and good agreement between the measured data and simulated results was obtained for both the rejection and recovery rates. Compared to an integrated model consisting of two models from the literature, the fouling model proposed in this study showed reliable performance for membrane fouling such as the increase in the permeate TDS concentration according to operating time. In addition, simulations for membrane maintenance were conducted based on the variation in membrane resistance, which reflects the fouling state of the membrane. These revealed that the rearrangement of membranes is not significantly effective without cleaning the fouled membrane. Instead, a partial replacement of membranes can be an effective maintenance scheme to increase the recovery rate. Accordingly, the results of the study presented here can be used to save operation and maintenance (O&M) costs in SWRO plants through the optimized management of fouled membranes.

[1]  Joaquim M. S. Cabral,et al.  Pressure Driven Membrane Processes , 1991 .

[2]  C. Seeton Viscosity–temperature correlation for liquids , 2006 .

[3]  Barry N. Taylor,et al.  Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results , 2017 .

[4]  Lianfa Song,et al.  A numerical study on concentration polarization and system performance of spiral wound RO membrane modules , 2006 .

[5]  Thomas Melin,et al.  State-of-the-art of reverse osmosis desalination , 2007 .

[6]  Lianfa Song Flux decline in crossflow microfiltration and ultrafiltration: mechanisms and modeling of membrane fouling , 1998 .

[7]  How Yong Ng,et al.  Influence of colloidal fouling on rejection of trace organic contaminants by reverse osmosis , 2004 .

[8]  Min Luo,et al.  Complex fouling and cleaning-in-place of a reverse osmosis desalination system , 2001 .

[9]  Lianfa Song,et al.  The development of membrane fouling in full-scale RO processes , 2004 .

[10]  Miguel Angel Sanza,et al.  Fujairah reverse osmosis plant: 2 years of operation , 2007 .

[11]  Dong-mei Xu,et al.  Optimum design of reverse osmosis seawater desalination system considering membrane cleaning and replacing , 2006 .

[12]  Abdul Ghani I. Dalvi,et al.  Studies on organic foulants in the seawater feed of reverse osmosis plants of SWCC , 2000 .

[13]  Pierre J. Carreau,et al.  Modeling of ultrafiltration : predictions of concentration polarization effects , 1994 .

[14]  Minkyu Park,et al.  A rapid performance diagnosis of seawater reverse osmosis membranes: simulation approach , 2010 .

[15]  H. F. Shaalan,et al.  Development of fouling control strategies pertinent to nanofiltration membranes , 2003 .

[16]  Menachem Elimelech,et al.  Influence of Crossflow Membrane Filter Geometry and Shear Rate on Colloidal Fouling in Reverse Osmosis and Nanofiltration Separations , 2002 .

[17]  Haruhiko Ohya,et al.  Several engineering equations in the design of reverse osmosis plants , 1991 .

[18]  Eric M.V. Hoek,et al.  Modeling the effects of fouling on full-scale reverse osmosis processes , 2008 .

[19]  Marilyn Barger,et al.  FOULING PREDICTION IN REVERSE OSMOSIS PROCESSES , 1991 .

[20]  Shoji Kimura,et al.  Fouling of cellulose acetate tubular reverse osmosis modules treating the industrial water in Tokyo , 1975 .