Intrapulmonary Feeding Tube Placements While Using an Electromagnetic Placement Device: A Review (2019-2021).

BACKGROUND Intrapulmonary placements of feeding tubes inserted with use of an electromagnetic placement device (EMPD) continue to occur. OBJECTIVE To describe circumstances and outcomes associated with intrapulmonary feeding tube placements during use of an EMPD. METHODS A retrospective review of reports to the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database of intrapulmonary feeding tube placements during use of an EMPD from 2019 through 2021. Complications, outcomes, operator training, interference from anatomical variations and medical devices, and the use and accuracy of radiographs in identifying pulmonary placements were recorded. RESULTS Sixty-two cases of intrapulmonary tube placement were identified; 10 were associated with a fatal outcome. Pneumothorax occurred in 35 cases and feedings were delivered into the lung in 11 cases. User error was cited in 6 cases and was implicit in most others. Little information was provided about operator training. Four intrapulmonary placements were associated with anatomical variations and 1 with a left ventricular assist device. Radiographic follow-up was described in 28 cases and correctly identified 23 of the intrapulmonary placements. CONCLUSIONS User error was a significant factor, which highlights the need for empirical data to clarify the amount of training needed to safely credential EMPD operators. Clearer information is needed about anatomical variations that may contraindicate use of an EMPD, as well as medical devices that may interfere with an EMPD. Use of follow-up radiographs, interpreted by qualified personnel, is supported to increase the probability of identifying intrapulmonary tube placements.

[1]  Lorraine H. Linford,et al.  Development of a competency model for placement and verification of nasogastric and nasoenteric feeding tubes for adult hospitalized patients. , 2021, Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition.

[2]  D. Toher,et al.  Cortrak feeding tube placement: accuracy of the 'GI flexure system' versus manufacturer guidance. , 2020, British journal of nursing.

[3]  R. Clemente,et al.  Undetected Cortrak tube misplacements in the United Kingdom 2010-17: An audit of trace interpretation. , 2019, Intensive & critical care nursing.

[4]  J. Hasse,et al.  Successful Placement of Nasointestinal Feeding Tubes Using an Electromagnetic Sensor‐Guided Enteral Access System in Patients With Left Ventricular Assist Devices , 2018, Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition.

[5]  Lorraine H. Linford,et al.  Improved Safety and Efficacy of Small‐Bore Feeding Tube Confirmation Using an Electromagnetic Placement Device , 2018, Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition.

[6]  R. Clemente,et al.  Cortrak tube placement part 2: guidance to avoid misplacement is inadequate. , 2017, British journal of nursing.

[7]  R. Carlson,et al.  Electromagnetic Tube-Placement Device: The Replacement for the Radiographic Gold Standard? , 2017, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[8]  A. Bourgault,et al.  Cortrak‐Assisted Feeding Tube Insertion: A Comprehensive Review of Adverse Events in the MAUDE Database , 2017, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[9]  N. Metheny,et al.  Update on Effectiveness of an Electromagnetic Feeding Tube‐Placement Device in Detecting Respiratory Placements , 2017, American Journal of Critical Care.

[10]  K. Abrams,et al.  Verifying placement of small-bore feeding tubes: electromagnetic device images versus abdominal radiographs. , 2015, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[11]  N. Metheny,et al.  Effectiveness of an electromagnetic feeding tube placement device in detecting inadvertent respiratory placement. , 2014, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[12]  Mary Fischer,et al.  Elimination of radiographic confirmation for small-bowel feeding tubes in critical care. , 2013, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[13]  D. Seidner,et al.  Small bowel feeding tube placement using an electromagnetic tube placement device: accuracy of tip location. , 2011, JPEN. Journal of parenteral and enteral nutrition.

[14]  K. Kudsk,et al.  A Team-Based Protocol and Electromagnetic Technology Eliminate Feeding Tube Placement Complications , 2011, Annals of surgery.

[15]  C. Pourzitaki,et al.  Ventricular tachycardia and cardiac arrest during nasogastric tube insertion. , 2010, Southern medical journal.

[16]  A. Bourgault,et al.  CORTRAK Superuser Competency Assessment and Training Recommendations , 2019, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[17]  B. Wessman,et al.  The case of the malpositioned feeding tube… while in plain sight , 2018 .

[18]  Wanda Whittet,et al.  Feeding Tube Insertion and Placement Confirmation Using Electromagnetic Guidance: A Team Review , 2018, JPEN. Journal of parenteral and enteral nutrition.

[19]  M. McCarthy,et al.  Analysis of an electromagnetic tube placement device versus a self-advancing nasal jejunal device for postpyloric feeding tube placement. , 2014, Journal of hospital medicine.