Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test.

PURPOSE The purpose of this study was to investigate, by finite element analysis (FEA) and fatigue analysis, the influence of different loading conditions on the stress distribution in a 3-unit implant-supported Y-TZP fixed partial denture (FPD). MATERIAL AND METHODS A three-dimensional FEM model was developed. The materials used in this study were assumed to be linearly elastic, homogeneous and isotropic. 100 N and 300 N loads over a 0,5 mm(2) areas with different angles (0°, 15° and 35°) and locations were applied on the prosthesis and the distribution of equivalent von Mises stress was investigated. A fatigue analysis was carried out too. RESULTS Maximum stresses were found at the connector region of the framework when the intermediate element is loaded (100 N load pattern: 32,9 MPa, 33 MPa and 51,8 MPa; 300 N load pattern: 98,6 MPa, 102,8 MPa and 155,7 MPa, respectively with 0°, 15° and 35° of inclination). Results confirmed the vulnerability of both connector areas even if just one pillar was loaded with an increase in stress when angle of load inclination is larger. The cyclic fatigue evaluation indicates a strong propensity for fatigue behavior, presenting a considerable range of loading conditions. No fracture fatigue occurred with a 100 N force. A 300 N force applied to the pontic produces no fatigue problems because the load is equally shared by whole system. A 300 N force applied to one of the two pillars, or to both implants generates fatigue problems. CONCLUSION F.E.M. analysis of a 3-unit implant-supported Y-TZPFPD, give accurate information about loading conditions for clinical success over time. Fatigue analysis results show structural reliability of the Y-TZP as framework material for 3-unit posterior FPDs.

[1]  J. Strub,et al.  Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study. , 2006, Quintessence international.

[2]  M Heller,et al.  Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia. , 1989, Journal of biomedical materials research.

[3]  K. Akca,et al.  Role of mechanical environment and implant design on bone tissue differentiation: current knowledge and future contexts. , 2004, Journal of dentistry.

[4]  G. Grathwohl,et al.  Crack Resistance and Fatigue of Transforming Ceramics: I, Materials in the ZrO2–Y2O3–Al2O3 System , 1991 .

[5]  A Schulman,et al.  A review of all-ceramic restorations. , 1997, Journal of the American Dental Association.

[6]  G. Grathwohl,et al.  Strengthening of Zirconia–Alumina During Cyclic Fatigue Testing , 1989 .

[7]  Michel Barquins,et al.  Relevance of the finite element method to optimize fixed partial denture design , 1998, Clinical Oral Investigations.

[8]  N H F Wilson,et al.  Finite element analysis of fixed partial denture replacement. , 2004, Journal of oral rehabilitation.

[9]  H Spiekermann,et al.  Status of current CAD/CAM technology in dental medicine. , 2004, International journal of computerized dentistry.

[10]  Georg Grathwohl,et al.  Crack resistance and fatigue of transforming ceramics. II : CeO2-stabilized tetragonal ZrO2 , 1991 .

[11]  M. Çehreli,et al.  The influence of functional forces on the biomechanics of implant-supported prostheses--a review. , 2002, Journal of dentistry.

[12]  J A Sorensen,et al.  A clinical investigation on three-unit fixed partial dentures fabricated with a lithium disilicate glass-ceramic. , 1999, Practical periodontics and aesthetic dentistry : PPAD.

[13]  Michael Smyth,et al.  Dimensions of metal framework components of metal-ceramic fixed partial dentures constructed in a dental school setting. , 2004, Quintessence international.

[14]  N. Götzen,et al.  Influence of Connector Design on Fracture Probability of Ceramic Fixed-partial Dentures , 2002, Journal of dental research.

[15]  M. Sevimay,et al.  Effects of cantilever design and material on stress distribution in fixed partial dentures--a finite element analysis. , 2005, Journal of oral rehabilitation.

[16]  J. Mccabe Perspectives in dental ceramics , 1989 .

[17]  J. Chevalier,et al.  Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses. , 2002, Biomaterials.

[18]  P Schärer,et al.  Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM). , 2001, International journal of computerized dentistry.

[19]  Bernt Andersson,et al.  A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs. , 2003, The International journal of prosthodontics.

[20]  G Zappini,et al.  Finite element analysis of a glass fibre reinforced composite endodontic post. , 2002, Biomaterials.

[21]  C. Piconi,et al.  Zirconia as a ceramic biomaterial. , 1999, Biomaterials.

[22]  Ariel J Raigrodski,et al.  All-ceramic fixed partial dentures, Part I: in vitro studies. , 2002, Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.].

[23]  A J Raigrodski,et al.  The safety and efficacy of anterior ceramic fixed partial dentures: A review of the literature. , 2001, The Journal of prosthetic dentistry.

[24]  P. Vult von Steyern,et al.  Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. , 2001, The International journal of prosthodontics.

[25]  G L Kinzel,et al.  A finite element survey of eleven endosseous implants. , 1990, The Journal of prosthetic dentistry.

[26]  Ariel J. Raigrodski Dmd,et al.  ALL-CERAMIC FIXED PARTIAL DENTURES, PART III: CLINICAL STUDIES , 2002 .

[27]  H Fischer,et al.  Lifetime Prediction of All-ceramic Bridges by Computational Methods , 2003, Journal of dental research.

[28]  Frank Filser,et al.  Strength and reliability of four-unit all-ceramic posterior bridges. , 2005, Dental materials : official publication of the Academy of Dental Materials.

[29]  S. Karlsson,et al.  A dental laboratory study of the dimensions of metal frameworks for fixed partial dentures. , 2000, European Journal of Prosthodontics and Restorative Dentistry.

[30]  B Rangert,et al.  Bending overload and implant fracture: a retrospective clinical analysis. , 1995, The International journal of oral & maxillofacial implants.

[31]  Michael V Swain,et al.  Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[32]  S. Bayne,et al.  Stress concentration in all-ceramic posterior fixed partial dentures. , 1996, Quintessence international.

[33]  Zhong-qin Lin,et al.  The predictions and applications of fatigue lifetime in alumina and zirconia ceramics , 2004 .

[34]  Atilla Sertgöz,et al.  Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[35]  Ariel J Raigrodski,et al.  Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. , 2004, The Journal of prosthetic dentistry.

[36]  Won-Suck Oh,et al.  Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. , 2002, The Journal of prosthetic dentistry.

[37]  D Lundgren,et al.  Influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentitions with implant-supported fixed prostheses occluding with complete dentures. , 1989, The International journal of oral & maxillofacial implants.

[38]  J A Tesk,et al.  Failure of All-ceramic Fixed Partial Dentures in vitro and in vivo: Analysis and Modeling , 1995, Journal of dental research.

[39]  H Knode,et al.  In-Ceram fixed partial dentures: three-year clinical trial results. , 1998, Journal of the California Dental Association.

[40]  Michael V Swain,et al.  Influence of core thickness on a restored crown of a first premolar using finite element analysis. , 2003, The International journal of prosthodontics.