Automatic vessel lumen segmentation and stent strut detection in intravascular optical coherence tomography.

PURPOSE Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution cross-sectional intravascular images. The authors propose a segmentation technique for automatic lumen area extraction and stent strut detection in intravascular OCT images for the purpose of quantitative analysis of neointimal hyperplasia (NIH). METHODS A clinical dataset of frequency-domain OCT scans of the human femoral artery was analyzed. First, a segmentation method based on the Markov random field (MRF) model was employed for lumen area identification. Second, textural and edge information derived from local intensity distribution and continuous wavelet transform (CWT) analysis were integrated to extract the inner luminal contour. Finally, the stent strut positions were detected via the introduction of each strut wavelet response across scales into a feature extraction and classification scheme in order to optimize the strut position detection. RESULTS The inner lumen contour and the position of stent strut were extracted with very high accuracy. Compared with manual segmentation by an expert vascular physician the automatic segmentation had an average overlap value of 0.937 ± 0.045 for all OCT images included in the study. The strut detection accuracy had an area under the curve (AUC) value of 0.95, together with sensitivity and specificity average values of 0.91 and 0.96, respectively. CONCLUSIONS A robust automatic segmentation technique integrating textural and edge information for vessel lumen border extraction and strut detection in intravascular OCT images was designed and presented. The proposed algorithm may be employed for automated quantitative morphological analysis of in-stent neointimal hyperplasia.

[1]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[2]  Donald F. Specht,et al.  Probabilistic neural networks , 1990, Neural Networks.

[3]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[4]  Nico Bruining,et al.  A novel approach to quantitative analysis of intra vascular ultrasound images , 2001, Computers in Cardiology 2001. Vol.28 (Cat. No.01CH37287).

[5]  A. Low,et al.  Technology Insight: optical coherence tomography—current status and future development , 2006, Nature Clinical Practice Cardiovascular Medicine.

[6]  Stéphane Mallat,et al.  Characterization of Signals from Multiscale Edges , 2011, IEEE Trans. Pattern Anal. Mach. Intell..

[7]  Satoshi Watanabe,et al.  Persistent malapposition after implantation of sirolimus-eluting stent into intramural coronary hematoma: optical coherence tomography observations. , 2006, Circulation journal : official journal of the Japanese Circulation Society.

[8]  Lucila Ohno-Machado,et al.  The use of receiver operating characteristic curves in biomedical informatics , 2005, J. Biomed. Informatics.

[9]  Gozde Unal,et al.  Automatic Stent Implant Follow-up in Intravascular Optical Coherence Tomography Images , 2008 .

[10]  N. Draper,et al.  Applied Regression Analysis: Draper/Applied Regression Analysis , 1998 .

[11]  Heinz-Otto Peitgen,et al.  Scale-space signatures for the detection of clustered microcalcifications in digital mammograms , 1999, IEEE Transactions on Medical Imaging.

[12]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[13]  D L Farkas,et al.  Detection of tumorigenesis in rat bladders with optical coherence tomography. , 2001, Medical physics.

[14]  Eloisa Arbustini,et al.  Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. , 2010, European heart journal.

[15]  E. Halpern,et al.  Characterization of Human Atherosclerosis by Optical Coherence Tomography , 2002, Circulation.

[16]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[17]  Gozde Unal,et al.  Stent implant follow-up in intravascular optical coherence tomography images , 2010, The International Journal of Cardiovascular Imaging.

[18]  Tony Lindeberg,et al.  Scale-space theory , 2001 .

[19]  Alejandro F Frangi,et al.  Dynamic estimation of three-dimensional cerebrovascular deformation from rotational angiography. , 2011, Medical physics.

[20]  Donald Geman,et al.  Stochastic Relaxation, Gibbs Distributions, and the Bayesian Restoration of Images , 1984, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[21]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[22]  Joseph M Schmitt,et al.  Current and future developments in intracoronary optical coherence tomography imaging. , 2009, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[23]  N. Bruining,et al.  A novel approach to quantitative analysis of intravascular optical coherence tomography imaging , 2008, 2008 Computers in Cardiology.

[24]  R. Brinks On the convergence of derivatives of B-splines to derivatives of the Gaussian function , 2008 .

[25]  Timothy Masters,et al.  Advanced algorithms for neural networks: a C++ sourcebook , 1995 .

[26]  Patrick W Serruys,et al.  A novel approach for quantitative analysis of intracoronary optical coherence tomography: High inter‐observer agreement with computer‐assisted contour detection , 2008, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[27]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[28]  Jeroen J. Bax,et al.  Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis. , 2008, JACC. Cardiovascular interventions.

[29]  E. Parzen On Estimation of a Probability Density Function and Mode , 1962 .

[30]  Richard F. Gunst,et al.  Applied Regression Analysis , 1999, Technometrics.

[31]  P. Serruys,et al.  Reproducibility of coronary Fourier domain optical coherence tomography: quantitative analysis of in vivo stented coronary arteries using three different software packages. , 2010, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[32]  N. Weissman,et al.  Plaque characterization with optical coherence tomography. , 2006, Journal of the American College of Cardiology.

[33]  C. D. Gelatt,et al.  Optimization by Simulated Annealing , 1983, Science.

[34]  Dirk H. Hoekman,et al.  Initialization of Markov random field clustering of large remote sensing images , 2005, IEEE Transactions on Geoscience and Remote Sensing.

[35]  A. Rollins,et al.  Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. , 2009, JACC. Cardiovascular interventions.

[36]  Andrew F. Laine,et al.  Circle recognition through a 2D Hough Transform and radius histogramming , 1999, Image Vis. Comput..

[37]  Evelyn Regar,et al.  Novelties in cardiac imaging--optical coherence tomography (OCT). , 2008, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[38]  Dimitris Karnabatidis,et al.  Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery , 2011, CardioVascular and Interventional Radiology.

[39]  J. Besag Spatial Interaction and the Statistical Analysis of Lattice Systems , 1974 .

[40]  Brett E. Bouma,et al.  In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography , 2005, Circulation.

[41]  Stan Z. Li,et al.  Markov Random Field Modeling in Computer Vision , 1995, Computer Science Workbench.

[42]  Jennifer K Barton,et al.  An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets , 2008, Physics in medicine and biology.

[43]  Maryellen L. Giger,et al.  Automated seeded lesion segmentation on digital mammograms , 1998, IEEE Transactions on Medical Imaging.

[44]  Stéphane Mallat,et al.  Singularity detection and processing with wavelets , 1992, IEEE Trans. Inf. Theory.

[45]  Dana H. Ballard,et al.  Generalizing the Hough transform to detect arbitrary shapes , 1981, Pattern Recognit..

[46]  Claude Kauffmann,et al.  In Vivo Supervised Analysis of Stent Reendothelialization From Optical Coherence Tomography , 2010, IEEE Transactions on Medical Imaging.