Techniques on partial discharge detection and location determination in power transformer

Insulation failure has been identified as one of the main reasons for transformer breakdown. As one the most important assets in the high voltage system, the loss of a power transformer will cause significant effects to consumers and on the system. The condition of the insulation can directly be correlated to the presence of Partial discharge (PD). Therefore, the ability to accurately detect and analyse the information from PD could be the answer to avoid catastrophic breakdown. On top of that, the capability to pinpoint the location of the PD source would enable swift preventive action to be taken. Several methods have been researched and developed in those two areas. This paper will discuss such techniques. Included in the discussion is an introduction to some less conventional techniques such as optical and ionising emission detection.

[1]  Y. M. Kim,et al.  Sensitivity verification and application of UHF sensor for partial discharge measurement in high voltage power transformer , 2012, 2012 IEEE International Conference on Condition Monitoring and Diagnosis.

[2]  H. Edin,et al.  Partial discharges in a cavity embedded in oil-impregnated paper: effect of electrical and thermal aging , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  Xi Chen,et al.  An all-fiber partial discharge monitoring system based on both intrinsic fiber optic interferometry sensor and fluorescent fiber , 2013, Other Conferences.

[5]  Jan Eikeset,et al.  Photon Activity from Partial Discharges in Liquid Dielectrics: Experimental test setup and measurements , 2014 .

[6]  Alexander Kraetge,et al.  Robust measurement, monitoring and analysis of partial discharges in transformers and other HV apparatus , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  Vladimiro Miranda,et al.  Mandrel-Based Fiber-Optic Sensors for Acoustic Detection of Partial Discharges—a Proof of Concept , 2010, IEEE Transactions on Power Delivery.

[8]  Xiaoxing Zhang,et al.  A Transformer Partial Discharge Measurement System Based on Fluorescent Fiber , 2012 .

[9]  S. Tenbohlen,et al.  Sensitivity of UHF PD measurements in power transformers , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  B. T. Phung,et al.  Partial discharge localization in transformers using UHF detection method , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[11]  Jian Cao,et al.  New sensor for gases dissolved in transformer oil based on solid oxide fuel cell , 2014 .

[12]  R. Sloan,et al.  Comparison of IEC 60270 and RF partial discharge detection in an electromagnetic noise-free environment at differing pressures , 2012, 2012 IEEE International Symposium on Electrical Insulation.

[13]  Ho-Joon Seo,et al.  Development of Gas Detector for Hydrogen Dissolved in Transformer Oil , 2005, 2005 IEEE Instrumentationand Measurement Technology Conference Proceedings.

[14]  M. Muhr,et al.  Experience with optical partial discharge detection , 2007 .

[15]  Martin D. Judd,et al.  Differentiating between partial discharge sources using envelope comparison of ultra-high-frequency signals , 2010 .

[16]  Mohd Raffi Samsudin,et al.  Incipient fault detection in 33/11kV power transformers by using combined Dissolved Gas Analysis technique and acoustic partial discharge measurement and validated through untanking , 2010, 2010 Modern Electric Power Systems.

[17]  Stefan Tenbohlen,et al.  Influence of PD Location in Transformer windings on IEC60270- and UHF-Measurements , 2010 .

[18]  M. M. Yaacob,et al.  Review on partial discharge detection techniques related to high voltage power equipment using different sensors , 2014 .

[19]  Jian Li,et al.  Canonical Correlation Between Partial Discharges and Gas Formation in Transformer Oil Paper Insulation , 2012, Energies.

[20]  Pavel Fiala,et al.  Detection of Partial Discharge inside of HV Transformer, Modeling, Sensors and Measurement , 2010 .

[21]  Hazlee Azil Illias,et al.  Partial discharge classifications: Review of recent progress , 2015 .

[22]  Chengrong Li,et al.  Location of PDs inside transformer windings using UHF methods , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  W. Ziomek,et al.  Location of partial discharge sources in power transformers based on advanced auscultatory technique , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  Julio E. Posada-Roman,et al.  Instrumentation System for Location of Partial Discharges Using Acoustic Detection With Piezoelectric Transducers and Optical Fiber Sensors , 2014, IEEE Transactions on Instrumentation and Measurement.

[26]  B. T. Phung,et al.  Recognition of single and multiple partial discharge sources in transformers based on ultra-high frequency signals , 2014 .

[27]  Martin D. Judd Experience with UHF partial discharge detection and location in power transformers , 2011, 2011 Electrical Insulation Conference (EIC)..

[28]  Xiao Yi,et al.  Comparison between Online and Laboratory Measurements of Fault Gases for Mineral Oil and Natural Ester , 2013 .

[29]  Xing Zhang,et al.  On-line Monitoring System Based on Principle of Electro-acoustic Monitoring for Transformer Partial Discharge , 2014 .

[30]  Jürgen Fabian,et al.  State of the Art of Unconventional PD-Measurement at Power Transformers , 2013 .

[32]  Jose A. Garcia-Souto,et al.  Multichannel fiber optic heterodyne interferometer for the acoustic detection of partial discharges , 2012, Other Conferences.

[33]  S. Tenbohlen,et al.  Fundamental differences of the PD measurement according to IEC 60270 and in UHF range , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[34]  U. Riechert,et al.  Sensitivity Evaluation of Different Types of PD Sensors for UHF-PD-Measurements , 2010 .

[35]  Enrique E. Mombello,et al.  Partial discharge location in power transformer windings using the wavelet Laplace function , 2014 .

[36]  Luo Yongfen,et al.  Comparison of DOA Algorithms Applied to Ultrasonic Arrays for PD Location in Oil , 2015, IEEE Sensors Journal.

[37]  Jun Jiang,et al.  Highly Sensitive Dissolved Hydrogen Sensor Based on Side-Polished Fiber Bragg Grating , 2015, IEEE Photonics Technology Letters.

[38]  E. Gockenbach,et al.  Advancing new techniques for UHF PDdetection and localization in the power transformers in the factory tests , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[39]  Moein Parastegari,et al.  Simultaneous location of two partial discharge sources in power transformers based on acoustic emission using the modified binary partial swarm optimisation algorithm , 2013 .

[40]  Jun Jiang,et al.  Fiber bragg grating sensor for hydrogen detection in power transformers , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[41]  Shuyi Cheng,et al.  Location of partial discharge in transformer oil using circular array of ultrasonic sensors , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[42]  Kun Wang,et al.  Transformer partial discharge monitoring based on optical fiber sensing , 2014 .

[43]  Fan Liu,et al.  Partial Discharge Optical Pulse Signal Characteristics for Corona Defect in Oil Immersed Transformer , 2013 .

[44]  Caixin Sun,et al.  Improved Bagging Algorithm for Pattern Recognition in UHF Signals of Partial Discharges , 2011 .

[45]  W. Ziomek,et al.  Detection, Recognition and Location of Partial Discharge Sources Using Acoustic Emission Method , 2012 .

[46]  C. Koley,et al.  A methodology for identification and localization of partial discharge sources using optical sensors , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[47]  Tomasz Boczar,et al.  Analysis of Ionizing Radiation Generated by Partial Discharges , 2014 .

[48]  M. S. Abd Rahman Identification of partial discharge sources and their location within high voltage transformer windings , 2014 .

[49]  Edward Gulski,et al.  SENSORS AND SENSING USED FOR NON-CONVENTIONAL PD DETECTION , 2006 .

[50]  R. Bartnikas,et al.  On-line detection and measurement of partial discharge signals in a noisy environment , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[51]  M. Hikita,et al.  A proposal for Hybrid PD sensor identifying absolute distance from PD source , 2013, 2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[52]  Jose A. Garcia-Souto,et al.  All-fiber interferometric sensor of 150kHz acoustic emission for the detection of partial discharges within power transformers , 2011, International Conference on Optical Fibre Sensors.

[53]  Alexander Kraetge,et al.  Application of the UHF technology to detect and locate partial discharges in liquid immersed transformer , 2014, Elektrotech. Informationstechnik.

[54]  Guo-ming Ma,et al.  High sensitive and reliable fiber Bragg grating hydrogen sensor for fault detection of power transformer , 2012 .

[55]  Debangshu Dey,et al.  Recent Trends in the Condition Monitoring of Transformers , 2013 .

[57]  Bernard Dam,et al.  Optical fiber sensor for the continuous monitoring of hydrogen in oil , 2014 .