Automatic Measurement of the Carotid Blood Flow for Wearable Sensors: A Pilot Study

The assessment of the velocity of blood flowing in the carotid, in modern clinical practice, represents an important exam performed both in emergency situations and as part of scheduled screenings. It is typically performed by an expert sonographer who operates a complex and costly clinical echograph. Unfortunately, in developing countries, in rural areas, and even in crowded modern cities, the access to this exam can be limited by the lack of suitable personnel and ultrasound equipment. The recent availability of low-cost, handheld devices has contributed to solving part of the problem, but a wide access to the exam is still hampered by the lack of expert sonographers. In this work, an automated procedure is presented with the hope that, in the near future, it can be integrated into a low-cost, handheld instrument that is also suitable for self-measurement, for example, as can be done today with the finger oximeter. The operator should only place the probe on the neck, transversally with respect to the common tract of the carotid. The system, in real-time, automatically locates the vessel lumen, places the sample volume, and performs an angle-corrected velocity measurement of the common carotid artery peak velocity. In this study, the method was implemented for testing on the ULA-OP 256 scanner. Experiments on flow phantoms and volunteers show a performance in sample volume placement similar to that achieved by expert operators, and an accuracy and repeatability of 3.2% and 4.5%, respectively.

[1]  F. Foster,et al.  A novel, hands-free ultrasound patch for continuous monitoring of quantitative Doppler in the carotid artery , 2021, Scientific Reports.

[2]  T. Effing,et al.  Is Bigger Really Better? Comparison of Ultraportable Handheld Ultrasound with Standard Point-of-Care Ultrasound for Evaluating Safe Site Identification and Image Quality prior to Pleurocentesis , 2020, Respiration.

[3]  Piero Tortoli,et al.  Real-Time Blood Velocity Vector Measurement Over a 2-D Region , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[4]  P. Tortoli,et al.  Improved blood velocity estimation using the maximum Doppler frequency. , 1995, Ultrasound in medicine & biology.

[5]  Ernesto Iadanza,et al.  Evidence-based medical equipment management: a convenient implementation , 2019, Medical & Biological Engineering & Computing.

[6]  Valentino Meacci,et al.  Data-Adaptive Coherent Demodulator for High Dynamics Pulse-Wave Ultrasound Applications , 2018, Electronics.

[7]  Richard O. Duda,et al.  Use of the Hough transformation to detect lines and curves in pictures , 1972, CACM.

[8]  S. Murthy,et al.  Intensive Care Unit Capacity in Low-Income Countries: A Systematic Review , 2015, PloS one.

[9]  M. Fox Multiple crossed-beam ultrasound Doppler velocimetry , 1978 .

[10]  Vida Pashaei,et al.  Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation , 2019, IEEE Transactions on Biomedical Circuits and Systems.

[11]  H. Ashrafian Anatomically specific clinical examination of the carotid arterial tree , 2007, Anatomical science international.

[12]  Jean-Philippe Thiran,et al.  Towards Ultrasound Everywhere: A Portable 3D Digital Back-End Capable of Zone and Compound Imaging , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[13]  Piero Tortoli,et al.  Accurate blood peak velocity estimation using spectral models and vector doppler , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[14]  Emmanouil G. Sifakis,et al.  Using the Hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery. , 2007, Ultrasound in medicine & biology.

[15]  Vernon L. Newhouse,et al.  Analysis of Transit Time Effects on Doppler Flow Measurement , 1976, IEEE Transactions on Biomedical Engineering.

[16]  Valentino Meacci,et al.  FPGA-Based Doppler Frequency Estimator for Real-Time Velocimetry , 2020, Electronics.

[17]  Piero Tortoli,et al.  Comparison of carotid artery blood velocity measurements by vector and standard Doppler approaches. , 2015, Ultrasound in medicine & biology.

[18]  Piero Tortoli,et al.  ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[19]  Swapna Banerjee,et al.  Smartphone-Based Point-of-Care System Using Continuous-Wave Portable Doppler , 2020, IEEE Transactions on Instrumentation and Measurement.

[20]  Alessandro Stuart Savoia,et al.  “Medical Assistance in Contextual awareness” (AMICO): a project for a better cardiopathic patients quality of care , 2019, 2019 IEEE 8th International Workshop on Advances in Sensors and Interfaces (IWASI).

[21]  N. Bjarnegård,et al.  Comparison of the multi‐phasic longitudinal displacement of the left and right common carotid artery in healthy humans , 2021, Clinical physiology and functional imaging.

[22]  R Eugene Zierler,et al.  Carotid artery stenosis: gray-scale and Doppler US diagnosis--Society of Radiologists in Ultrasound Consensus Conference. , 2003, Radiology.

[23]  F. Quaglia,et al.  Toward Automatic Measurement of Carotid Blood Velocity , 2019, 2019 IEEE International Ultrasonics Symposium (IUS).

[24]  Jeffrey A. Neasham,et al.  Development of a Low-Cost Medical Ultrasound Scanner Using a Monostatic Synthetic Aperture , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[25]  Aart J. Nederveen,et al.  Review: Mechanical Characterization of Carotid Arteries and Atherosclerotic Plaques , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[26]  Richard S C Cobbold,et al.  Human factors as a source of error in peak Doppler velocity measurement. , 2005, Journal of vascular surgery.

[27]  Arantxa Uranga,et al.  Miniaturized 0.13-μm CMOS Front-End Analog for AlN PMUT Arrays , 2020, Sensors.

[28]  Kalpana Reddy Fully Automated Segmentation and Tracking of the Intima Media Thickness in Ultrasound Video Sequences of the Common Carotid Artery , 2014 .

[29]  Mohanasankar Sivaprakasam,et al.  An Imageless Ultrasound Device to Measure Local and Regional Arterial Stiffness , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[30]  W. McDicken,et al.  Doppler Ultrasound: Physics, Instrumentation and Signal Processing , 2000 .

[31]  Elad Alon,et al.  Miniaturizing Ultrasonic System for Portable Health Care and Fitness , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[32]  Jongmin Yoon,et al.  Design and Implementation of a New Wireless Carotid Neckband Doppler System with Wearable Ultrasound Sensors: Preliminary Results , 2019, Applied Sciences.

[33]  Johan G. Bosch,et al.  Design of an Ultrasound Transceiver ASIC with a Switching-Artifact Reduction Technique for 3D Carotid Artery Imaging , 2021, Sensors.

[34]  Scott E Kasner,et al.  Carotid Artery Diameter in Men and Women and the Relation to Body and Neck Size , 2006, Stroke.

[35]  Piero Tortoli,et al.  Clinical validation of common carotid artery wall distension assessment based on multigate Doppler processing. , 2005, Ultrasound in medicine & biology.

[36]  Jae Jin Lee,et al.  A System-on-Chip Solution for Point-of-Care Ultrasound Imaging Systems: Architecture and ASIC Implementation , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[37]  S. Matsuo,et al.  Common carotid flow velocity is associated with cognitive function after carotid endarterectomy , 2020, Journal of Clinical Neuroscience.

[38]  D. Bandyk Follow-up after carotid endarterectomy and stenting: What to look for and why. , 2020, Seminars in vascular surgery.

[39]  Piero Tortoli,et al.  Accuracy and reproducibility of a novel dynamic volume flow measurement method. , 2013, Ultrasound in medicine & biology.

[40]  Nikhil V. Divekar,et al.  Wearable , 2018, Encyclopedia of Education and Information Technologies.

[41]  Hamid Soleimani,et al.  Quadrature Synthetic Aperture Beamforming Front-End for Miniaturized Ultrasound Imaging , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[42]  Omer T Inan,et al.  Wearable Sensors Incorporating Compensatory Reserve Measurement for Advancing Physiological Monitoring in Critically Injured Trauma Patients , 2020, Sensors.