Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths
暂无分享,去创建一个
Chris Van Hoof | Shuang Song | Nick Van Helleputte | Rik Vullings | Dwaipayan Biswas | Willemijn Groenendaal | Yifan Zhang | Neide Simoes-Capela | N. V. Helleputte | C. Hoof | R. Vullings | W. Groenendaal | Yifan Zhang | Shuang Song | N. Simões-Capela | Dwaipayan Biswas
[1] Zhilin Zhang,et al. A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts , 2017, Sensors.
[2] Alex Young,et al. Characterization and reduction of motion artifacts in photoplethysmographic signals from a wrist-worn device , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).
[3] J. Lee,et al. Wearable Multichannel Photoplethysmography Framework for Heart Rate Monitoring During Intensive Exercise , 2018, IEEE Sensors Journal.
[4] Jean-Marc Vesin,et al. Robust heart rate estimation using wrist-type photoplethysmographic signals during physical exercise: an approach based on adaptive filtering , 2017, Physiological measurement.
[5] Zhilin Zhang,et al. Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction , 2015, IEEE Transactions on Biomedical Engineering.
[6] Hoon Ko,et al. Wearable Photoplethysmographic Sensor Based on Different LED Light Intensities , 2017, IEEE Sensors Journal.
[7] E. Hari Krishna,et al. A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter , 2012, IEEE Transactions on Instrumentation and Measurement.
[8] Manan Bawa,et al. Comparison of different signal processing methods for reducing artifacts from photoplethysmograph signal , 2011, 2011 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY.
[9] Alexander J. Casson,et al. Gyroscope vs. accelerometer measurements of motion from wrist PPG during physical exercise , 2016, ICT Express.
[10] Zhilin Zhang,et al. TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise , 2014, IEEE Transactions on Biomedical Engineering.
[11] Takehiro Yamakoshi,et al. iPhone 4s Photoplethysmography: Which Light Color Yields the Most Accurate Heart Rate and Normalized Pulse Volume Using the iPhysioMeter Application in the Presence of Motion Artifact? , 2014, PloS one.
[12] Alexander J. Casson,et al. Description of a Database Containing Wrist PPG Signals Recorded during Physical Exercise with Both Accelerometer and Gyroscope Measures of Motion , 2017, Data.
[13] Philippe Renevey,et al. Wrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[14] C. M. Lee,et al. Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach , 2003, IEEE EMBS Asian-Pacific Conference on Biomedical Engineering, 2003..
[15] H. Lee,et al. Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope , 2019, IEEE Sensors Journal.
[16] Vytautas Vizbara. Comparison of Green, Blue and Infrared Light in Wrist and Forehead Photoplethysmography , 2013, BioMed 2013.
[17] Lei Wang,et al. Multichannel Reflective PPG Earpiece Sensor With Passive Motion Cancellation , 2007, IEEE Transactions on Biomedical Circuits and Systems.
[18] Yu Sun,et al. Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging , 2016, IEEE Transactions on Biomedical Engineering.
[19] Mehrdad Nourani,et al. A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors , 2014, IEEE Journal of Biomedical and Health Informatics.
[20] Rwcgr Ralph Wijshoff,et al. On photoplethysmography artifact reduction and applications , 2016 .
[21] Ki Chang Nam,et al. Measurement Site and Applied Pressure Consideration in Wrist Photoplethysmography , 2008 .
[22] Sayeed Shafayet Chowdhury,et al. Real-Time Robust Heart Rate Estimation From Wrist-Type PPG Signals Using Multiple Reference Adaptive Noise Cancellation , 2018, IEEE Journal of Biomedical and Health Informatics.
[23] Andriy Temko,et al. Estimation of heart rate from photoplethysmography during physical exercise using Wiener filtering and the phase vocoder , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).
[24] S. M. A. Salehizadeh,et al. Motion and Noise Artifact Detection and Vital Signal Reconstruction in ECG/PPG based Wearable Devices , 2015 .