Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths

Long-term heart rate (HR) monitoring by wrist-worn photoplethysmograph (PPG) sensors enables the assessment of health conditions during daily life with high user comfort. However, PPG signals are vulnerable to motion artifacts (MAs), which significantly affect the accuracy of estimated physiological parameters such as HR. This paper proposes a novel modular algorithm framework for MA removal based on different wavelengths for wrist-worn PPG sensors. The framework uses a green PPG signal for HR monitoring and an infrared PPG signal as the motion reference. The proposed framework includes four main steps: motion detection, motion removal using continuous wavelet transform, approximate HR estimation and signal reconstruction. The proposed algorithm is evaluated against an electrocardiogram (ECG) in terms of HR error for a dataset of 6 healthy subjects performing 21 types of motion. The proposed MA removal method reduced the average error in HR estimation from 4.3, 3.0 and 3.8 bpm to 0.6, 1.0 and 2.1 bpm in periodic, random, and continuous non-periodic motion situations, respectively.

[1]  Zhilin Zhang,et al.  A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts , 2017, Sensors.

[2]  Alex Young,et al.  Characterization and reduction of motion artifacts in photoplethysmographic signals from a wrist-worn device , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[3]  J. Lee,et al.  Wearable Multichannel Photoplethysmography Framework for Heart Rate Monitoring During Intensive Exercise , 2018, IEEE Sensors Journal.

[4]  Jean-Marc Vesin,et al.  Robust heart rate estimation using wrist-type photoplethysmographic signals during physical exercise: an approach based on adaptive filtering , 2017, Physiological measurement.

[5]  Zhilin Zhang,et al.  Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction , 2015, IEEE Transactions on Biomedical Engineering.

[6]  Hoon Ko,et al.  Wearable Photoplethysmographic Sensor Based on Different LED Light Intensities , 2017, IEEE Sensors Journal.

[7]  E. Hari Krishna,et al.  A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter , 2012, IEEE Transactions on Instrumentation and Measurement.

[8]  Manan Bawa,et al.  Comparison of different signal processing methods for reducing artifacts from photoplethysmograph signal , 2011, 2011 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY.

[9]  Alexander J. Casson,et al.  Gyroscope vs. accelerometer measurements of motion from wrist PPG during physical exercise , 2016, ICT Express.

[10]  Zhilin Zhang,et al.  TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise , 2014, IEEE Transactions on Biomedical Engineering.

[11]  Takehiro Yamakoshi,et al.  iPhone 4s Photoplethysmography: Which Light Color Yields the Most Accurate Heart Rate and Normalized Pulse Volume Using the iPhysioMeter Application in the Presence of Motion Artifact? , 2014, PloS one.

[12]  Alexander J. Casson,et al.  Description of a Database Containing Wrist PPG Signals Recorded during Physical Exercise with Both Accelerometer and Gyroscope Measures of Motion , 2017, Data.

[13]  Philippe Renevey,et al.  Wrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  C. M. Lee,et al.  Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach , 2003, IEEE EMBS Asian-Pacific Conference on Biomedical Engineering, 2003..

[15]  H. Lee,et al.  Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope , 2019, IEEE Sensors Journal.

[16]  Vytautas Vizbara Comparison of Green, Blue and Infrared Light in Wrist and Forehead Photoplethysmography , 2013, BioMed 2013.

[17]  Lei Wang,et al.  Multichannel Reflective PPG Earpiece Sensor With Passive Motion Cancellation , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[18]  Yu Sun,et al.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging , 2016, IEEE Transactions on Biomedical Engineering.

[19]  Mehrdad Nourani,et al.  A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors , 2014, IEEE Journal of Biomedical and Health Informatics.

[20]  Rwcgr Ralph Wijshoff,et al.  On photoplethysmography artifact reduction and applications , 2016 .

[21]  Ki Chang Nam,et al.  Measurement Site and Applied Pressure Consideration in Wrist Photoplethysmography , 2008 .

[22]  Sayeed Shafayet Chowdhury,et al.  Real-Time Robust Heart Rate Estimation From Wrist-Type PPG Signals Using Multiple Reference Adaptive Noise Cancellation , 2018, IEEE Journal of Biomedical and Health Informatics.

[23]  Andriy Temko,et al.  Estimation of heart rate from photoplethysmography during physical exercise using Wiener filtering and the phase vocoder , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[24]  S. M. A. Salehizadeh,et al.  Motion and Noise Artifact Detection and Vital Signal Reconstruction in ECG/PPG based Wearable Devices , 2015 .