Effect of vacuum on the performance of the flame ionization detector used for vacuum‐outlet gas chromatography

Vacuum-outlet operation of short fused-silica open tubular columns for gas chromatography provides benefits to analysis speed by increasing the optimum velocity while minimizing the loss in resolution. Vacuum-outlet operation of a column with a gas chromatographic detector necessitates that the detector also be under vacuum. Simple modifications were made to a gas chromatograph–flame ionization detector (GC–FID) for vacuum-inlet and vacuum-outlet operation. The vacuum-inlet system was operated in the splitless mode to allow for efficient sample loading prior to operation at reduced pressures. The goal of FID operation at 100 torr or less was achieved by using oxygen in place of air and optimizing the gas flows under vacuum to maintain a stable flame at pressures as low as 46 torr. An outlet pressure of 85 torr with optimized gas flows allowed for routine operation of the FID without solvent flame-out. It was discovered that the sensitivity is enhanced compared to atmospheric operation over a range of outlet pressures from approximately 200 to 400 torr; however, operation of the FID at the lowest possible pressures decreases the analytical sensitivity due to both the outlet pressure and the absence of helium makeup gas. © 2000 John Wiley & Sons, Inc. J Micro Sep 12: 226–235, 2000

[1]  R. Sacks,et al.  High-speed, vacuum-outlet GC using atmospheric-pressure air as carrier gas , 1999 .

[2]  R. Sacks,et al.  High-Speed Gas Extraction of Volatile and Semivolatile Organic Compounds from Aqueous Samples , 1998 .

[3]  R. Sacks,et al.  Stepper motor controlled micro gas valve inlet system for gas chromatography. , 1998, Analytical chemistry.

[4]  Robert L. Grob,et al.  Modern Practice of Gas Chromatography , 1995 .

[5]  U. Bernier,et al.  Vacuum operation of the flame-ionization detector for gas chromatography , 1993 .

[6]  R. Sacks,et al.  Strategies for rapid GC impurity analysis of high-purity solvents I : instrumentation and procedures , 1991 .

[7]  R. Sacks,et al.  Low-Pressure Gas Chromatography with Split Injection and Photoionization Detection , 1991 .

[8]  Zaiyou Liu,et al.  High-Speed Gas Chromatographic Analysis of a Simulated Process Stream using On-Column Thermal Desorption Modulation for Sample Preconcentration and Introduction , 1990 .

[9]  R. Yost,et al.  Theoretical and practical aspects of short open tubular columns at subambient pressures in gas chromatography/mass spectrometry , 1989 .

[10]  C. Cramers,et al.  Detection limits of thermal conductivity and photoionization detectors in high speed narrow bore CGC , 1989 .

[11]  A. V. Es,et al.  Detectability and the resulting requirements for column-detector systems in capillary gas chromatography , 1988 .

[12]  S. Levine,et al.  Electrically heated cold trap inlet system for computer-controlled high-speed gas chromatography. , 1988, Analytical chemistry.

[13]  C. Cramers,et al.  Considerations on speed of separation, detection, and identification limits in capillary GC and GC/MS , 1988 .

[14]  C. Cramers,et al.  Sample introduction in high speed capillary gas chromatography; input band width and detection limits , 1987 .

[15]  C. Cramers,et al.  Minimum analysis time in capillary gas chromatography : vacuum- versus atmospheric-outlet column operation , 1987 .

[16]  K. Hyver,et al.  Considerations in enhancing resolution, speed, and sensitivity in capillary gas chromatography and gas chromatography—mass spectrometry , 1987 .

[17]  Richard A. Yost,et al.  Short open tubular columns in gas chromatography/mass spectrometry , 1986 .

[18]  C. Cramers,et al.  Increased speed of analysis in directly coupled gas chromatography-mass spectrometry systems. II.Advantages of vacuum outlet operation of thick-film capillary columns , 1982 .

[19]  C. Cramers,et al.  Increased speed of analysis in directly coupled gas chromatography-mass spectrometry systems : capillary columns at sub-atmospheric outlet pressures , 1981 .

[20]  P. Sandra,et al.  Influence of the vacuum on the separation efficiency in coupled (GC)2-MS , 1979 .

[21]  M. E. Parrish,et al.  Vacuum gas chromatography using short glass capillary columns combined with mass spectrometry , 1978 .

[22]  G. Guiochon,et al.  Influence of GC-MS Coupling on the Performances of a Chromatographic Column , 1970 .

[23]  S. Palamand,et al.  Low pressure gas chromatography , 1969 .

[24]  J. Giddings Theory of Minimum Time Operation in Gas Chromatography. , 1962 .